Optimization of the Seismic Performance of a Steel-Concrete Wind Turbine Tower with the Tuned Mass Damper

被引:7
作者
Yue, Yanchao [1 ]
Li, Changxin [1 ]
Jia, Kai [1 ]
Zhang, Yuhang [1 ]
Tian, Jingjing [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Architecture & Engn, Xian 710049, Peoples R China
关键词
steel-concrete wind turbine tower; tuned mass damper; mass ratio; layout; DESIGN; JOINT;
D O I
10.3390/buildings12091474
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To optimize the seismic performance of a new type of steel-concrete tower, a 120 m steel-concrete composite tower model with a tuned mass damper (TMD) was constructed in ABAQUS for simulation analysis. Firstly, a time history analysis was conducted to study the towers with and without a TMD to determine the difference in their accelerations, velocities, and displacements. Then, a frequency spectrum analysis was performed to determine the tower vibration reduction effect of TMDs with different mass ratios. Five different cases were considered to explore the impact of different layouts on the dynamic performance of the tower. The results showed that the TMD had a significant vibration reduction effect on the tower accelerations, velocities, and displacements. The acceleration was reduced the most, while the vibration reduction effect in the middle of the tower was more significant than that at the top of the tower. For the steel-concrete tower studied in this paper, the optimal mass ratio of TMD was found to be 0.01. Placing one TMD at the top and another in the middle of the tower was found to be the optimal TMD arrangement for tower vibration reduction.
引用
收藏
页数:16
相关论文
共 44 条
  • [1] Agbayani Nestor A., 2012, Proceedings of the 2012 Structures Congress. Structures Congress 2012, P1201, DOI 10.1061/9780784412367.108
  • [2] Alshurafa S.A, 2012, THESIS U MANITOBA WI
  • [3] Finite element method for the static and dynamic analysis of FRP guyed tower
    Alshurafa, Sami
    Alhayek, Hanan
    Polyzois, Dimos
    [J]. JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2019, 6 (03) : 436 - 446
  • [4] [Anonymous], 2010, Code for design of concrete structures
  • [5] [Anonymous], 2009, EQUIP MANUFACTRING T
  • [6] Optimized Design of a Tuned Mass Damper Inerter (TMDI) Applied to Circular Section Members of Transmission Towers
    Bian, Yongfei
    Liu, Xinpeng
    Sun, Yi
    Zhong, Yongli
    [J]. BUILDINGS, 2022, 12 (08)
  • [7] Seismic performance of offshore wind turbine in the vicinity of seamount subduction zone
    Chaudhari, Vasudeo
    Somala, Surendra Nadh
    [J]. STRUCTURES, 2021, 34 : 423 - 432
  • [8] Tuned rolling-ball dampers for vibration control in wind turbines
    Chen, Junling
    Georgakis, Christos T.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2013, 332 (21) : 5271 - 5282
  • [9] Cotrell J., ANAL TRANSPORTATION
  • [10] Compressive behaviour of tapered concrete-filled double skin steel tubular stub columns
    Deng, Ran
    Zhou, Xu-Hong
    Deng, Xiao-Wei
    Ke, Ke
    Bai, Jiu-Lin
    Wang, Yu-Hang
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184