Surface Electromyography Characteristics for Motion Intention Recognition and Implementation Issues in Lower-limb Exoskeletons

被引:26
|
作者
Kyeong, Seulki [1 ]
Feng, Jirou [1 ]
Ryu, Jae Kwan [2 ]
Park, Jung Jae [2 ]
Lee, Kyeong Ha [2 ]
Kim, Jung [1 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Dept Mech Engn, Daejeon 34141, South Korea
[2] LIG Nex 1, 333 Pangyo Ro, Seongnam Si, Gyeonggi Do, South Korea
关键词
Disturbance force; exoskeleton; surface electromyography (sEMG); walking environment; EMG; ORTHOSES; STRATEGY; FATIGUE;
D O I
10.1007/s12555-020-0934-3
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recognizing the user's motion intentions is a crucial challenge to develop human augmented robotic devices due to safety and easiness of interactions. Among the possible sensorial modalities, surface electromyography (sEMG) signals have been tested to be a primary motion intention channel due to the inherent advantage of electromechanical delay and the muscle activation information. However, the lack of detailed sEMG characteristics as motion recognition has been difficult issues to develop safe and intuitive interactions with the robots. In this study, we evaluated the sEMG characteristics for their potential applicability to recognizing the motion intentions of humans. For the discrete motion intention recognition, the walking environments were classified using only sEMG signals by support vector machine (SVM) and linear discriminated analysis (LDA) models with accuracy of 79.1% and 76.3%. Due to the fact that it is crucial to identify an unexpected disturbance by the collision between the exoskeleton and surrounding environment in recognizing the user intention to guarantee the safety of the user, sEMG and torque sensors were used to classify user-intended interaction forces and disturbance forces in the event of collisions. A control algorithm was proposed that detects and compensates for collisions, and its performance showed that robust motion intention recognition and control of powered exoskeletons are possible. We investigated the effect of muscle fatigue caused by long-term walking with heavy load wearing an exoskeleton. The sEMG amplitude and frequency were analyzed for muscle fatigue due to single-joint (knee extensions) and multi-joint (walking) exercises, and muscle fatigue due to walking was prominent in the signal from the vastus medialis (VM). The characteristics of sEMG due to muscle fatigue should be seriously considered in continuous motion estimation.
引用
收藏
页码:1018 / 1028
页数:11
相关论文
共 50 条
  • [31] Human motion intention recognition method with visual, audio, and surface electromyography modalities for a mechanical hand in different environments
    Xiao, Feiyun
    Zhang, Zhen
    Liu, Changhai
    Wang, Yong
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [32] An Adaptive Neuromuscular Controller for Assistive Lower-Limb Exoskeletons: A Preliminary Study on Subjects with Spinal Cord Injury
    Wu, Amy R.
    Dzeladini, Florin
    Brug, Tycho J. H.
    Tamburella, Federica
    Tagliamonte, Nevio L.
    van Asseldonk, Edwin H. F.
    van der Kooij, Herman
    Ijspeert, Auke J.
    FRONTIERS IN NEUROROBOTICS, 2017, 11
  • [33] Momentum-based trajectory planning for lower-limb exoskeletons supporting sit-to-stand transitions
    Patil G.
    Rigoli L.
    Richardson M.J.
    Kumar M.
    Lorenz T.
    International Journal of Intelligent Robotics and Applications, 2018, 2 (2) : 180 - 192
  • [34] Exploring surface electromyography (EMG) as a feedback variable for the human-in-the-loop optimization of lower limb wearable robotics
    Grimmer, Martin
    Zeiss, Julian
    Weigand, Florian
    Zhao, Guoping
    FRONTIERS IN NEUROROBOTICS, 2022, 16
  • [35] Electromyography of selected lower-limb muscles fatigued by exercise at the intensity of soccer match-play
    Rahnama, N
    Lees, A
    Reilly, T
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2006, 16 (03) : 257 - 263
  • [36] Analysis of the Anklebot Training as a Method for Reducing Lower-Limb Paretic Impairment A Case Study in Electromyography
    Swaminathan, Krithika
    Krebs, Hermano Igo
    PROCEEDINGS OF THE IEEE/RAS-EMBS INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR 2015), 2015, : 555 - 558
  • [37] Lower limb joint angle estimation based on surface electromyography signals
    Lv, Hongzhan
    Wang, Yunrui
    Hao, Boda
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 104
  • [38] Prediction of Joint Angles Based on Human Lower Limb Surface Electromyography
    Zhao, Hongyu
    Qiu, Zhibo
    Peng, Daoyong
    Wang, Fang
    Wang, Zhelong
    Qiu, Sen
    Shi, Xin
    Chu, Qinghao
    SENSORS, 2023, 23 (12)
  • [39] Lower-Limb Exoskeletons Appeal to Both Clinicians and Older Adults, Especially for Fall Prevention and Joint Pain Reduction
    Raitor, Michael
    Ruggles, Sandra Waugh
    Delp, Scott L.
    Liu, C. Karen
    Collins, Steven H.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 1577 - 1585
  • [40] Gait Phase Recognition for Lower-Limb Exoskeleton with Only Joint Angular Sensors
    Liu, Du-Xin
    Wu, Xinyu
    Du, Wenbin
    Wang, Can
    Xu, Tiantian
    SENSORS, 2016, 16 (10)