Surface Electromyography Characteristics for Motion Intention Recognition and Implementation Issues in Lower-limb Exoskeletons

被引:26
|
作者
Kyeong, Seulki [1 ]
Feng, Jirou [1 ]
Ryu, Jae Kwan [2 ]
Park, Jung Jae [2 ]
Lee, Kyeong Ha [2 ]
Kim, Jung [1 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Dept Mech Engn, Daejeon 34141, South Korea
[2] LIG Nex 1, 333 Pangyo Ro, Seongnam Si, Gyeonggi Do, South Korea
关键词
Disturbance force; exoskeleton; surface electromyography (sEMG); walking environment; EMG; ORTHOSES; STRATEGY; FATIGUE;
D O I
10.1007/s12555-020-0934-3
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recognizing the user's motion intentions is a crucial challenge to develop human augmented robotic devices due to safety and easiness of interactions. Among the possible sensorial modalities, surface electromyography (sEMG) signals have been tested to be a primary motion intention channel due to the inherent advantage of electromechanical delay and the muscle activation information. However, the lack of detailed sEMG characteristics as motion recognition has been difficult issues to develop safe and intuitive interactions with the robots. In this study, we evaluated the sEMG characteristics for their potential applicability to recognizing the motion intentions of humans. For the discrete motion intention recognition, the walking environments were classified using only sEMG signals by support vector machine (SVM) and linear discriminated analysis (LDA) models with accuracy of 79.1% and 76.3%. Due to the fact that it is crucial to identify an unexpected disturbance by the collision between the exoskeleton and surrounding environment in recognizing the user intention to guarantee the safety of the user, sEMG and torque sensors were used to classify user-intended interaction forces and disturbance forces in the event of collisions. A control algorithm was proposed that detects and compensates for collisions, and its performance showed that robust motion intention recognition and control of powered exoskeletons are possible. We investigated the effect of muscle fatigue caused by long-term walking with heavy load wearing an exoskeleton. The sEMG amplitude and frequency were analyzed for muscle fatigue due to single-joint (knee extensions) and multi-joint (walking) exercises, and muscle fatigue due to walking was prominent in the signal from the vastus medialis (VM). The characteristics of sEMG due to muscle fatigue should be seriously considered in continuous motion estimation.
引用
收藏
页码:1018 / 1028
页数:11
相关论文
共 50 条
  • [21] Recent Advances in Pediatric Wearable Lower-Limb Exoskeletons for Gait Rehabilitation: A Systematic Review
    Pacheco-Cherrez, Josue
    Tudon-Martinez, Juan C.
    Lozoya-Santos, Jorge de J.
    IEEE ACCESS, 2025, 13 : 50511 - 50533
  • [22] Development of surface electromyography-based motion intention recognition for human-machine interface
    Xu, Tinghan
    Qi, Shichen
    Liang, Yuanhao
    Hu, Yong
    2024 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS, CIVEMSA 2024, 2024,
  • [23] Safety Augmentation for Volitional Human Locomotion via Lower-Limb Exoskeletons: A Case Study
    Yu, Miao
    Lin, Qin
    Lv, Ge
    IEEE CONTROL SYSTEMS LETTERS, 2024, 8 : 778 - 783
  • [24] Lower-Limb Electromyography Signal Analysis of Distinct Muscle Fitness Norms under Graded Exercise Intensity
    Chen, Ching-Kun
    Lin, Shyan-Lung
    Wang, Tasi-Chu
    Lin, Yu-Jie
    Wu, Chieh-Liang
    ELECTRONICS, 2020, 9 (12) : 1 - 10
  • [25] IMPLEMENTATION OF AN ADJUSTABLE COMPLIANT KNEE JOINT IN A LOWER-LIMB EXOSKELETON
    Sanz-Merodio, D.
    Cestari, M.
    Arevalo, J. C.
    Garcia, E.
    NATURE INSPIRED MOBILE ROBOTICS, 2013, : 223 - 231
  • [26] Preliminary Evaluation of Intelligent Intention Estimation Algorithms for an Actuated Lower-Limb Exoskeleton Regular Paper
    Chandrapal, Mervin
    Chen, XiaoQi
    Wang, Wenhui
    Stanke, Benjamin
    Le Pape, Nicolas
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2013, 10
  • [27] Lower-limb exoskeletons for individuals with chronic spinal cord injury: findings from a feasibility study
    Benson, Ian
    Hart, Kirsten
    Tussler, Dot
    van Middendorp, Joost J.
    CLINICAL REHABILITATION, 2016, 30 (01) : 73 - 84
  • [28] Lower-Limb Electromyography Signal Analysis for the Bottom Group of Muscles Fitness Norm before and after Intensive Exercise
    Chen, Ching-Kun
    Lin, Shyan-Lung
    Wang, Tasi-Chu
    Huang, Yang-Si
    Wu, Chieh-Liang
    ELECTRONICS, 2021, 10 (20)
  • [29] Lower Limb Motion Classification Using Energy Density Features of Surface Electromyography Signals' Activation Region and Dynamic Ensemble Model
    Qin, Pengjie
    Shi, Xin
    Han, Kesong
    Fan, Zhirui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [30] Research on Lower Limb Step Speed Recognition Method Based on Electromyography
    Zhang, Peng
    Wu, Pengcheng
    Wang, Wendong
    MICROMACHINES, 2023, 14 (03)