New, fast corroding high ductility Mg-Bi-Ca and Mg-Bi-Si alloys, with no clinically observable gas formation in bone implants

被引:81
作者
Remennik, S. [1 ]
Bartsch, I. [2 ]
Willbold, E. [2 ]
Witte, F. [2 ]
Shechtman, D. [1 ,3 ]
机构
[1] Technion Israel Inst Technol, Dept Mat Engn, IL-32000 Haifa, Israel
[2] Hannover Med Sch, Orthopaed Clin, Lab Biomech & Biomat, D-30625 Hannover, Germany
[3] Iowa State Univ, MSE, Ames, IA 50011 USA
来源
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS | 2011年 / 176卷 / 20期
关键词
Magnesium alloys; Biodegradable metal; In-vivo tests; BIODEGRADABLE MAGNESIUM SCAFFOLDS; IN-VIVO CORROSION; BISMUTH; TOXICITY;
D O I
10.1016/j.mseb.2011.07.011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Current approaches to initial corrosion rate reduction of biodegradable magnesium alloys include alloying with rare earth elements, mechanical processing, coatings and the use of metallic glasses. The latter has limited ductility needed for implant adaptively to various surgery procedures. Furthermore, slow corroding magnesium alloys, coatings or metallic glasses have not proved to be fully dissolvable in vivo. With this in mind, we have developed a new class of biocompatible, biodegradable ductile magnesium alloys with 40% elongation at room temperature. The alloys are based on the Mg-Bi system and undergo a series of production routes, which include rapid solidification (RS) and various extrusion processes. The Mg-Bi-Si (B-BS) system exhibited a high corrosion rates in vitro and was excluded from in vivo screening. In preliminary experiments of Mg-Bi-Ca (B-BX) in rabbit femur bones, the alloy corroded rapidly without any clinically visible gas formation. Only 30% of the B-BX implant remained uncorroded after 4 weeks of implantation. After using low iron Mg for implant preparation the corrosion rate of HP-B-BX was reduced in bone leaving 70% of the implant uncorroded after 4 weeks, while the corrosion in intramuscular and subcutaneous sites were still high leaving only 40% and 10% uncorroded after 4 weeks. The foreign body reaction was very mild and enhanced bone formation could be observed in the vicinity of the corroding implant. Thus, these new magnesium alloys are potentially promising biomaterials, although more detailed in vivo studies need to be performed in actual implant situations. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1653 / 1659
页数:7
相关论文
共 20 条
[1]   Corrosion behaviour of AZ31 magnesium alloy with different grain sizes in simulated biological fluids [J].
Alvarez-Lopez, M. ;
Dolores Pereda, Maria ;
del Valle, J. A. ;
Fernandez-Lorenzo, M. ;
Garcia-Alonso, M. C. ;
Ruano, O. A. ;
Escudero, M. L. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1763-1771
[2]   Determination of Trimethylbismuth in the Human Body after Ingestion of Colloidal Bismuth Subcitrate [J].
Boertz, Jens ;
Hartmann, Louise Michele ;
Sulkowski, Margareta ;
Hippler, Joerg ;
Mosel, Frank ;
Diaz-Bone, Roland Arturo ;
Michalke, Klaus ;
Rettenmeier, Albert Wolfgang ;
Hirner, Alfred Vitalis .
DRUG METABOLISM AND DISPOSITION, 2009, 37 (02) :352-358
[3]   Grain refinement of AZ31 and ZK60 Mg alloys - towards superplasticity studies [J].
Bussiba, A ;
Ben Artzy, A ;
Shtechman, A ;
Ifergan, S ;
Kupiec, M .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2001, 302 (01) :56-62
[4]  
*FARL INC, BISM LIN
[5]  
FRIBERG L, 1986, HDB TOXICOLOGY METAL, P117
[6]   Magnesium hydroxide temporarily enhancing osteoblast activity and decreasing the osteoclast number in peri-implant bone remodelling [J].
Janning, C. ;
Willbold, E. ;
Vogt, C. ;
Nellesen, J. ;
Meyer-Lindenberg, A. ;
Windhagen, H. ;
Thorey, F. ;
Witte, F. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1861-1868
[7]   Processing and mechanical properties of fine-grained magnesium alloys [J].
Kubota, K ;
Mabuchi, M ;
Higashi, K .
JOURNAL OF MATERIALS SCIENCE, 1999, 34 (10) :2255-2262
[8]  
Luckey TD., 1977, Metal Toxicity in Mammals: Physiologic and chemical basis for metal toxicity
[9]   Oral toxicity of bismuth in rat: Single and 28-day repeated administration studies [J].
Sano, Y ;
Satoh, H ;
Chiba, M ;
Okamoto, M ;
Serizawa, K ;
Nakashima, H ;
Omae, K .
JOURNAL OF OCCUPATIONAL HEALTH, 2005, 47 (04) :293-298
[10]   A 13-week toxicity study of bismuth in rats by intratracheal intermittent administration [J].
Sano, Y ;
Satoh, H ;
Chiba, M ;
Shinohara, A ;
Okamoto, M ;
Serizawa, K ;
Nakashima, H ;
Omae, K .
JOURNAL OF OCCUPATIONAL HEALTH, 2005, 47 (03) :242-248