The influence of the Cole-Cole model parameters on the time constant of the recovery voltage decay of paper-oil insulation

被引:0
|
作者
Wolny, Stefan [1 ]
机构
[1] Politech Opolska, Inst Elektroenerget, Wydzial Elektrotech Automat & Informat, PL-45758 Opole, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2008年 / 84卷 / 03期
关键词
recovery voltage; paper-oil insulation; Cole-Cole model; power transformers;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes the application of the Cole-Cole model for determining the recovery voltage runs of a paper-oil insulation sample through computer simulation. Time constant tau(u) of the recovery voltage decay was selected as the parameter determining the condition of the insulation sample under study. Different insulation conditions were simulated by a proper selection of parameters alpha and tau of the Cole-Cole model. For calculation purposes a substitute series-parallel scheme, obtained by the application of the lumped approximation of discrete characteristic impedance Z(u) of the model applied was used.
引用
收藏
页码:26 / 28
页数:3
相关论文
共 29 条
  • [1] Influence of Temperature and Moisture Level in Paper-Oil Insulation on the Parameters of the Cole-Cole Model
    Wolny, Stefan
    Adamowicz, Artur
    Lepich, Marek
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (01) : 246 - 250
  • [2] Analysis of Recovery Voltage Parameters of Paper-Oil Insulation Obtained from Simulation Investigations Using the Cole-Cole Model
    Wolny, S.
    Zdanowski, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (06) : 1676 - 1680
  • [3] The application of the Cole-Cole model for determining the characteristics of depolarization current of paper-oil insulation
    Wolny, Stefan
    Zdanowski, Maciej
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (03): : 29 - 31
  • [4] The influence of the Cole-Cole model parameters on the characteristics of depolarization current of paper oil insulation
    Wolny, Stefan
    Kedzia, Jozef
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 291 - 294
  • [5] The analysis of the paper-oil insulation aging process using the X-Y type diagram and the Cole-Cole model
    Wolny, Stefan
    Zdanowski, Maciej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11B): : 304 - 306
  • [6] Cole-Cole Representation of Transformer Oil-Paper Insulation Dielectric Response
    Ojha, S. K.
    Purkait, P.
    Chakravorti, S.
    2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2017, : 36 - 41
  • [7] Application of Cole-Cole model to transformer oil-paper insulation considering distributed dielectric relaxation
    Ojha, Sandip Kumar
    Purkait, Prithwiraj
    Chatterjee, Biswendu
    Chakravorti, Sivaji
    HIGH VOLTAGE, 2019, 4 (01): : 72 - 79
  • [9] Influence of temperature on Cole-Cole dielectric model of oil-immersed bushing
    Wang, K.
    Chen, X. J.
    Xu, X. W.
    Liu, G. Q.
    Zou, D. X.
    Liu, W. D.
    2ND INTERNATIONAL CONFERENCE ON DESIGN, MATERIALS, AND MANUFACTURING, 2017, 220
  • [10] Diagnostics of the paper-oil insulation condition using selected parameters of recovery voltage
    Wolny, Stefan
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 214 - 217