Three-dimensional printing of navigational template in localization of pulmonary nodule: A pilot study

被引:44
作者
Zhang, Lei [1 ]
Li, Mu [1 ]
Li, Zeyao [1 ]
Kedeer, Xiermaimaiti [1 ]
Wang, Long [1 ]
Fan, Ziwen [1 ]
Chen, Chang [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Pulm Hosp, Dept Thorac Surg, Shanghai 200443, Peoples R China
基金
中国国家自然科学基金;
关键词
three-dimensional printing; localization; lung nodule; navigational template; video-assisted thoracoscopic surgery; ASSISTED THORACOSCOPIC SURGERY; HOOK WIRE LOCALIZATION; PREOPERATIVE MARKING; RESECTION; UTILITY;
D O I
10.1016/j.jtcvs.2017.08.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Small pulmonary nodules are a common problem, especially with the wide implementation of lung cancer-screening program. This poses a great challenge to thoracic surgeons because of the difficulty of nodule localization. We recently built an efficient, customized navigational template using 3-dimensional (3D) printing technology to facilitate the procedure of lung nodule localization. This study aims to investigate its feasibility in clinical application. Methods: Patients with peripheral lung nodules (< 2 cm) were enrolled. Preadmission computed tomography images were downloaded and reconstructed into a 3D model. A digital model of the navigational template was designed via computer-aided design software and then exported into 3D printer to produce physical template. The precision of the template-guided nodule localization and associated complications were evaluated. Results: A total of 16 patients were enrolled, and 18 nodules were localized through template-guided localization. The success rate of lung nodule localization was 100%, and the median time of localization was 13 minutes (range 10-16 minutes). In our series, no significant complication occurred, except for 2 asymptomatic pneumothoraxes. The median deviation between the localizer and the center of the nodule was 10.0 mm, ranging from 5 to 20 mm. Conclusions: This novel navigational template created by 3D printing technology is feasible, and it has acceptable accuracy for the application in lung nodule localization. The use of this navigational template could facilitate the procedure of lung nodule localization and may potentially break the dependence of percutaneous localization on computed tomography scanning.
引用
收藏
页码:2113 / +
页数:14
相关论文
共 13 条
[1]   The Utility of Electromagnetic Navigational Bronchoscopy as a Localization Tool for Robotic Resection of Small Pulmonary Nodules [J].
Bolton, William D. ;
Howe, Harold, III ;
Stephenson, James E. .
ANNALS OF THORACIC SURGERY, 2014, 98 (02) :471-476
[2]   Preoperative computed tomography-guided microcoil localization of small peripheral pulmonary nodules: A prospective randomized controlled trial [J].
Finley, Richard J. ;
Mayo, John R. ;
Grant, Kyle ;
Clifton, Joanne C. ;
English, John ;
Leo, Joyce ;
Lam, Stephen .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (01) :26-31
[3]   Efficacy and Complications of Computed Tomography-Guided Hook Wire Localization [J].
Ichinose, Junji ;
Kohno, Tadasu ;
Fujimori, Sakashi ;
Harano, Takashi ;
Suzuki, Souichiro .
ANNALS OF THORACIC SURGERY, 2013, 96 (04) :1203-1208
[4]   Three dimensional printing: A review on the utility within medicine and otolaryngology [J].
Kaye, Rachel ;
Goldstein, Todd ;
Zeltsman, David ;
Grande, Daniel A. ;
Smith, Lee P. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 89 :145-148
[6]   Comparative Effectiveness and Safety of Preoperative Lung Localization for Pulmonary Nodules A Systematic Review and Meta-analysis [J].
Park, Chul Hwan ;
Han, Kyunghwa ;
Hur, Jin ;
Lee, Sang Min ;
Lee, Ji Won ;
Hwang, Sung Ho ;
Seo, Jae Seung ;
Lee, Kye Ho ;
Kwon, Woocheol ;
Kim, Tae Hoon ;
Choi, Byoung Wook .
CHEST, 2017, 151 (02) :316-328
[7]   3D printing based on imaging data: review of medical applications [J].
Rengier, F. ;
Mehndiratta, A. ;
von Tengg-Kobligk, H. ;
Zechmann, C. M. ;
Unterhinninghofen, R. ;
Kauczor, H. -U. ;
Giesel, F. L. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (04) :335-341
[8]   3D haptic modelling for preoperative planning of hepatic resection: A systematic review [J].
Soon, David S. C. ;
Chae, Michael P. ;
Pilgrim, Charles H. C. ;
Rozen, Warren Matthew ;
Spychal, Robert T. ;
Hunter-Smith, David J. .
ANNALS OF MEDICINE AND SURGERY, 2016, 10 :1-7
[9]   Video-assisted thoracoscopic surgery for small indeterminate pulmonary nodules - Indications for preoperative marking [J].
Suzuki, K ;
Nagai, K ;
Yoshida, J ;
Ohmatsu, H ;
Takahashi, K ;
Nishimura, M ;
Nishiwaki, Y .
CHEST, 1999, 115 (02) :563-568
[10]   Usefulness of CT-guided hookwire marking before video-assisted thoracoscopic surgery for small pulmonary lesions [J].
Suzuki, Kazushi ;
Shimohira, Masashi ;
Hashizume, Takuya ;
Ozawa, Yoshiyuki ;
Sobue, Ryoji ;
Mimura, Mikio ;
Mori, Yuji ;
Ijima, Hidenori ;
Watanabe, Kenichi ;
Yano, Motoki ;
Yoshioka, Hiromu ;
Shibamoto, Yuta .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2014, 58 (06) :657-662