Repeatability of spirometry in 18,000 adult patients

被引:127
作者
Enright, PL
Beck, KC
Sherrill, DL
机构
[1] Univ Arizona, Dept Med, Tucson, AZ USA
[2] Univ Iowa Hosp & Clin, Dept Radiol, Iowa City, IA 52242 USA
关键词
spirometry; quality control; airway obstruction; lung-function standards;
D O I
10.1164/rccm.200204-347OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The objective of this study was to determine the limits for repeatability of FEV1, FVC, and PEF during spirometry test sessions in adult outpatients. A retrospective chart review of 18,000 consecutive patients, aged 20 to 90 years, referred to a large outpatient pulmonary function laboratory for testing was performed. Measurements included the differences between the highest and second-highest FVC (dFVC), FEV1 (dFEV(1)), and PEF (dPEF), from prebronchodilator spirometry, and anthropometric factors. Ninety percent of the patients were able to reproduce FEV1 within 120 ml (6.1%), FVC within 150 ml (5.3%), and PEF within 0.80 L (12%). Patient characteristics, such as sex, age, height, smoking status, and FEV1 (% predicted), had very little effect on repeatability, explaining only 2 to 4% of the variation in repeatability (expressed in milliliters). We conclude that the ability of patients to meet or exceed spirometry repeatability goals does not depend on patient characteristics when testing is performed by experienced personnel. The current American Thoracic Society repeatability goal of 200 ml for FEV1 and FVC may be too lenient.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 19 条
  • [1] [Anonymous], 1987, Am Rev Respir Dis, V136, P1285
  • [2] [Anonymous], 1995, AM J RESP CRIT CARE, V152, P1107
  • [3] Improvement in lung function measurements using a flow spirometer that emphasizes computer assessment of test quality
    Banks, DE
    Wang, ML
    McCabe, L
    Billie, M
    Hankinson, J
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1996, 38 (03) : 279 - 283
  • [4] BECKLAKE M, 1991, AM REV RESPIR DIS, V144, P1202
  • [5] SOURCES OF VARIATION IN FEV(1)
    COATES, AL
    DESMOND, KJ
    DEMIZIO, D
    ALLEN, PD
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (02) : 439 - 443
  • [6] SPIROMETRY REFERENCE VALUES FOR WOMEN AND MEN 65 TO 85 YEARS OF AGE - CARDIOVASCULAR HEALTH STUDY
    ENRIGHT, PL
    KRONMAL, RA
    HIGGINS, M
    SCHENKER, M
    HAPONIK, EF
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (01): : 125 - 133
  • [7] SPIROMETRY IN THE LUNG HEALTH STUDY .1. METHODS AND QUALITY-CONTROL
    ENRIGHT, PL
    JOHNSON, LR
    CONNETT, JE
    VOELKER, H
    BUIST, AS
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (06): : 1215 - 1223
  • [8] Spirometry reference values for healthy elderly blacks
    Enright, PL
    Arnold, A
    Manolio, TA
    Kuller, LH
    [J]. CHEST, 1996, 110 (06) : 1416 - 1424
  • [9] Quality of spirometry test performance in children and adolescents - Experience in a large field study
    Enright, PL
    Linn, WS
    Avol, EL
    Margolis, HG
    Gong, H
    Peters, JM
    [J]. CHEST, 2000, 118 (03) : 665 - 671
  • [10] Office spirometry for lung health assessment in adults - A consensus statement from the National Lung Health Education Program
    Ferguson, GT
    Enright, PL
    Buist, AS
    Higgins, MW
    [J]. CHEST, 2000, 117 (04) : 1146 - 1161