An approach to modelling envelope airtightness in multi-family social housing in Mediterranean Europe based on the situation in Spain

被引:55
作者
Fernandez-Aguera, Jesica [1 ]
Dominguez-Amarillo, Samuel [2 ]
Jose Sendra, Juan [2 ]
Suarez, Rafael [2 ]
机构
[1] CSIC, Inst Ciencias Construcc Eduardo Torroja, Madrid, Spain
[2] Univ Seville, Escuela Tecn Super Arquitectura, Inst Univ Arquitectura & Ciencias Construcc, Seville, Spain
关键词
Airtightness; Residential buildings; Blower Door test; Air infiltration; Southern europe; AIR-TIGHTNESS; ENERGY DEMAND; LEAKAGE; BUILDINGS; DWELLINGS; PERMEABILITY;
D O I
10.1016/j.enbuild.2016.06.074
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building hygrothermal performance, indoor air quality and energy consumption depend heavily on envelope airtightness. Over the last three decades, single-family dwellings have been amply studied in this respect by researchers in North Europe, the United States and Canada. However, very few studies have been conducted on airtightness in multi-family housing in warm climates such as Mediterranean Europe. This paper aims to enhance the understanding of building airtightness in early twenty-first-century multi-family buildings in southern Spain. Blower Door tests were conducted in 45 units in seven such buildings. The main airtightness parameter values found are reported and compared to the data for other buildings in southern Europe. The paper includes a statistical analysis of the findings, characterises building types and describes the protocol used to identify and quantify air leakage pathways. The conclusion drawn is that although a rough predictive model can be developed, the results are widely scattered due to the impact of the random component of manual construction, even in buildings with identical construction characteristics and types. The values recorded are nonetheless consistent with the findings for other European surveys. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 253
页数:18
相关论文
共 46 条
[11]  
Carrie R., 2006, PERMEABILITEI AIR EN
[12]  
Carswell T., 2012, ENCY HOUSING
[13]  
Chan W.R., 2012, ANAL AIR LEAKAGE MEA
[14]   Analysis of air leakage measurements of US houses [J].
Chan, Wanyu R. ;
Joh, Jeffrey ;
Sherman, Max H. .
ENERGY AND BUILDINGS, 2013, 66 :616-625
[15]   Analyzing a database of residential air leakage in the United States [J].
Chan, WYR ;
Nazaroff, WW ;
Price, PN ;
Sohn, MD ;
Gadgil, AJ .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (19) :3445-3455
[16]  
Dol K., 2010, HOUSING STAT EUROPEA
[17]   Towards Energy Demand Reduction in Social Housing Buildings: Envelope System Optimization Strategies [J].
Dominguez, Samuel ;
Sendra, Juan J. ;
Leon, Angel L. ;
Esquivias, Paula M. .
ENERGIES, 2012, 5 (07) :2263-2287
[18]  
Etheridge DW., 1996, Building ventilation: theory and measurement
[19]  
Ferrari S., 2015, Building Energy Performance Assessment in Southern Europe
[20]   MEASUREMENTS OF AIR PERMEABILITY IN MULTIZONE BUILDINGS [J].
FEUSTEL, HE .