Femoral artery Doppler ultrasound is more accurate than manual palpation for pulse detection in cardiac arrest

被引:27
作者
Cohen, Allison L. [1 ,2 ]
Li, Timmy [1 ,2 ]
Becker, Lance B. [1 ,2 ,3 ]
Owens, Casey [2 ,3 ]
Singh, Neha [3 ]
Gold, Allen [4 ]
Nelson, Mathew J. [1 ,2 ]
Jafari, Daniel [1 ,2 ]
Haddad, Ghania [2 ]
Nello, Alexander, V [1 ,2 ]
Rolston, Daniel M. [1 ,2 ]
机构
[1] Donald & Barbara Zucker Sch Med Hofstra Northwell, Dept Emergency Med, Hempstead, NY USA
[2] Northwell Hlth, North Shore Univ Hosp, Dept Emergency Med, Manhasset, NY USA
[3] Northwell Hlth, Feinstein Inst Med Res, Manhasset, NY USA
[4] Alleghany Hlth Network, St Vincent Hosp, Dept Emergency Med, Erie, NY USA
关键词
Cardiac arrest; Cardiopulmonary resuscitation; Doppler ultrasound; Pulse detection; OF-CARE ULTRASOUND; CARDIOPULMONARY-RESUSCITATION; LIFE-SUPPORT; BLOOD-PRESSURE; ELECTRICAL-ACTIVITY; CAROTID PULSE; VELOCITY; GUIDELINES; CHECK; ASSOCIATION;
D O I
10.1016/j.resuscitation.2022.01.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Our primary objective was to assess the accuracy of Doppler ultrasound versus manual palpation in detecting any pulse with an arterial line waveform in cardiac arrest. Secondarily, we sought to determine whether peak systolic velocity (PSV) on Doppler ultrasound could detect a pulse with a systolic blood pressure (SBP) >= 60 mmHg. Methods: We conducted a prospective, cross-sectional, diagnostic accuracy study on a convenience sample of adult, Emergency Department (ED) cardiac arrest patients. All patients had a femoral arterial line. During a pulse check, manual pulse detection, PSV and Doppler ultrasound clips, and SBP were recorded. A receiver operator characteristic curve analysis was performed to determine the optimal cut-off of PSV associated with a SBP >= 60 mmHg. Accuracy of manual palpation and Doppler ultrasound for detection of any pulse and SBP >= 60 mmHg were compared with McNemar's test. Results: 54 patients and 213 pulse checks were analysed. Doppler ultrasound demonstrated higher accuracy than manual palpation (95.3% vs. 54.0%; p < 0.001) for detection of any pulse. Correlation between PSV and SBP was strong (Spearman correlation coefficient = 0.89; p < 0.001). The optimal cut-off value of PSV associated with a SBP >= 60 mmHg was 20 cm/s (area under the curve = 0.975). To detect SBP >= 60 mmHg, accuracy of a PSV >= 20 cm/s was higher than manual palpation (91.4% vs. 66.2%; p < 0.001). Conclusions: Among ED cardiac arrest patients, femoral artery Doppler ultrasound was more accurate than manual palpation for detecting any pulse. When using a PSV >= 20 cm/s, Doppler ultrasound was also more accurate for detecting a SBP >= 60 mmHg.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 42 条
[2]   The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound [J].
Badra, Karine ;
Coutin, Alexandre ;
Simard, Robert ;
Pinto, Ruxandra ;
Lee, Jacques S. ;
Chenkin, Jordan .
RESUSCITATION, 2019, 139 :17-23
[3]   Skills of lay people in checking the carotid pulse [J].
Bahr, J ;
Klingler, H ;
Panzer, W ;
Rode, H ;
Kettler, D .
RESUSCITATION, 1997, 35 (01) :23-26
[4]   Focused echocardiographic evaluation in life support and pen-resuscitation of emergency patients: A prospective trial [J].
Breitkreutz, Raoul ;
Price, Susanna ;
Steiger, Holger V. ;
Seeger, Florian H. ;
Ilper, Hendrik ;
Ackermann, Hanns ;
Rudolph, Marcus ;
Uddin, Shahana ;
Weigand, Markus A. ;
Mueller, Edgar ;
Walcher, Felix .
RESUSCITATION, 2010, 81 (11) :1527-1533
[5]   Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: A prospective cohort study [J].
Clattenburg, Eben J. ;
Wroe, Peter ;
Brown, Stephen ;
Gardner, Kevin ;
Losonczy, Lia ;
Singh, Amandeep ;
Nagdev, Arun .
RESUSCITATION, 2018, 122 :65-68
[6]   STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration [J].
Cohen, Jeremie F. ;
Korevaar, Daniel A. ;
Altman, Douglas G. ;
Bruns, David E. ;
Gatsonis, Constantine A. ;
Hooft, Lotty ;
Irwig, Les ;
Levine, Deborah ;
Reitsma, Johannes B. ;
de Vet, Henrica C. W. ;
Bossuyt, Patrick M. M. .
BMJ OPEN, 2016, 6 (11)
[7]   Accuracy of the advanced trauma life support guidelines for predicting systolic blood pressure using carotid, femoral and radial pulses: observational study [J].
Deakin, CD ;
Low, JL .
BRITISH MEDICAL JOURNAL, 2000, 321 (7262) :673-674
[8]   Duplex velocity characteristics of aortoiliac stenoses [J].
deSmet, AAEA ;
Ermers, EJM ;
Kitslaar, PJEHM .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (04) :628-636
[9]   The carotid pulse check revisited: What if there is no pulse? [J].
Dick, WF ;
Eberle, B ;
Wisser, G ;
Schneider, T .
CRITICAL CARE MEDICINE, 2000, 28 (11) :N183-N185
[10]   Checking the carotid pulse check: Diagnostic accuracy of first responders in patients with and without a pulse [J].
Eberle, B ;
Dick, WF ;
Schneider, T ;
Wisser, G ;
Doetsch, S ;
Tzanova, I .
RESUSCITATION, 1996, 33 (02) :107-116