Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields

被引:12
作者
Fartaria, M. J. [1 ,2 ,7 ,8 ]
Reis, C. [2 ,3 ]
Pereira, J. [1 ,4 ]
Pereira, M. F. [1 ,4 ]
Cardoso, J. V. [1 ]
Santos, L. M. [1 ]
Oliveira, C. [1 ,4 ]
Holovey, V. [5 ]
Pascoal, A. [2 ,6 ]
Alves, J. G. [1 ,4 ]
机构
[1] Univ Lisbon, IST, LPSR, Estr Nacl 10,Ao Km 139,7, P-2986066 Bobadela, Portugal
[2] Univ Catolica Portuguesa, Fac Engn, Estr Octavio Pato, P-2635631 Rio De Mouro, Portugal
[3] Escola Super Tecnol Saude Lisboa ESTESL, Ave D Joao 2,Lote 4-69-01, P-1990096 Lisbon, Portugal
[4] UL, IST, C2TN, EN 10,Ao Km 139,7, P-2986066 Bobadela, Portugal
[5] Ukrainian Acad Sci, Inst Electron Phys, 21 Univ Str, UA-88017 Uzhgorod, Ukraine
[6] Kings Coll Hosp NHS Fdn Trust, Dept Med Engn & Phys, London, England
[7] CHU Vaudois, Dept Radiol, Lausanne, Switzerland
[8] Univ Lausanne UNIL, Lausanne, Switzerland
关键词
mammography; radiation quality; dosimetry; thermoluminescence; radiation dose assessment; DOSIMETRY;
D O I
10.1088/0031-9155/61/17/6384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this paper is the characterization of four thermoluminescence detectors (TLD), namely, LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu for the measurement of the entrance surface air kerma (ESAK) and estimation of the mean glandular dose (MGD) in digital mammography examinations at hospitals and clinics. Low-energy x-ray beams in the typical energy ranges of mammography, produced with a tungsten target and additional 60 mu m molybdenum filtration were implemented and characterized at the Laboratory of Metrology of Ionizing Radiation at Instituto Superior Tecnico. These beams were used for the characterization of the TLDs in terms of sensitivity, linearity, reproducibility, energy dependence and fading at 40 degrees C. The energy dependence test was further extended using clinical beams produced by mammography units at hospitals and clinics. The method proposed by the International Atomic Energy Agency was used for the measurement of ESAK and assessment of MGD. The combined standard uncertainty for the measurement of ESAK (and MGD) was determined in accordance to the Guide to the expression of uncertainty in measurement. The x-ray beams generated in the 23-40 kV(p) range presented HVL values from 0.36 to 0.46 mm Al. The beam produced at 28 kV(p) (HVL 0.39 mm Al) was considered as reference. The radiation field defined a circle with 84 mm diameter with a maximum variation of the beam intensity of less than 1% at the top flat (plateau) within 4 cm of the central axis. The estimated total uncertainty for the measurement of air kerma was 0.42%. All the TL detectors tested showed good performance except the commercial Li2B4O7:Mn (or TLD-800) which was excluded due to its poor sensitivity in our experimental set up. Both lithium fluorides showed better linearity and reproducibility as well as lower energy dependence and fading when compared to lithium borates. The stable behaviour of LiF:Mg,Ti and LiF:Mg,Cu,P detectors is reflected in the low combined standard uncertainty of +/- 5.6% and +/- 4.3% respectively (or +/- 5.1% and +/- 3.6% if fading is neglected). In general a total combined uncertainty lower than +/- 10% for the measurement of ESAK was obtained for the four TL materials studied.
引用
收藏
页码:6384 / 6399
页数:16
相关论文
共 27 条
[1]   A comparative study on the thermal stability of LiF:Mg,Ti and LiF:Mg,Cu,P detectors for environmental monitoring [J].
Alves, JG ;
Muñiz, JL ;
Ros, JMG ;
Delgado, A .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :253-257
[2]  
[Anonymous], 1964, PHYS ASP IRR NAT BUR, V85
[3]  
[Anonymous], 16263 EUR
[4]  
[Anonymous], 2011, IAEA Human Health Series.
[5]  
*BIPM, 2009, EV MEAS DAT INTR GUI
[6]  
Bushberg JT., 2002, The Essential Physics of Medical Imaging, V2, P191
[7]   Measurement of some dosimetric parameters for two mammography systems using thermoluminescent dosimetry [J].
Camargo-Mendoza, Raul E. ;
Poletti, Martin E. ;
Costa, Alessandro M. ;
Caldas, Linda V. E. .
RADIATION MEASUREMENTS, 2011, 46 (12) :2086-2089
[8]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240
[9]  
DELGADO A, 1992, RADIAT PROT DOSIM, V45, P101
[10]  
Horowitz Y.S., 1984, Thermoluminescence and Thermoluminescent Dosimetry, v, V2