Fault location method of IGBT short-circuit for a grid-tied Neutral-Point-Clamped inverter system

被引:3
|
作者
Ma, Mingyao [1 ]
Meng, Xuesong [1 ]
Xiang, Nianwen [1 ]
Wang, Hanyu [1 ]
Zhang, Xing [1 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Natl & Local Joint Engn Lab Renewable Energy Acce, Hefei, Peoples R China
基金
中国国家自然科学基金;
关键词
Neutral-Point-Clamped (NPC) grid-tied inverter; Insulated gate bipolar transistor (IGBT); Short-circuit fault; Fault location; GATE DRIVER; PROTECTION;
D O I
10.1016/j.microrel.2021.114225
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the Neutral-Point-Clamped (NPC) three-level grid-tied inverter, when IGBT short-circuit happens, the hardware protection would be triggered immediately to block all drive signals. After the system shuts down the fault location cannot be learned. This paper proposes a short-circuit fault location method for the internal switches of the NPC topology, based on the current loop analysis after system shuts down. The proposed method does not need to add additional sensors, only by means of the existing monitoring data can be completed fast diagnosis. The experimental results verify the feasibility and effectiveness of the proposed fault location method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fault location method of IGBT short-circuit for a grid-tied Neutral-Point-Clamped inverter system
    Ma, Mingyao
    Meng, Xuesong
    Xiang, Nianwen
    Wang, Hanyu
    Zhang, Xing
    Xiang, Nianwen (xiangnianwen@hfut.edu.cn), 1600, Elsevier Ltd (126):
  • [2] Detection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems
    Kim, Tae-Jin
    Lee, Woo-Cheol
    Hyun, Dong-Seok
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (07) : 2754 - 2763
  • [3] Performance Improvement of a Grid-Tied Neutral-Point-Clamped 3-φ Transformerless Inverter Using Model Predictive Control
    Albalawi, Hani
    Zaid, Sherif A.
    PROCESSES, 2019, 7 (11)
  • [4] Fault Tolerant Active Neutral Point Clamped Inverter: Short-Circuit and Open-Circuit Failures
    de Lacerda, Antonio Isaac L.
    da Silva, Edison Roberto C.
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 1068 - 1073
  • [5] Novel Hybrid Neutral Point Clamped Inverter for Single-Phase Grid-Tied Transformerless Inverter
    Geetha, K.
    Sreenivasappa, B., V
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (02): : 730 - 736
  • [6] Neutral Point Clamped MOSFET Inverter With Full-Bridge Configuration for Nonisolated Grid-Tied Photovoltaic System
    Anandababu, Chakravartula
    Fernandes, Baylon G.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2017, 5 (01) : 445 - 457
  • [7] Impedance Modeling and Stability Analysis of Three-Level Neutral-Point-Clamped Grid-Tied Inverters
    Zhang, Bo
    Du, Xiong
    Zou, Xiaoming
    Fan, Lijuan
    Wu, Songrong
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 2082 - 2087
  • [8] A Single-Stage Buck-Boost Three-Level Neutral-Point-Clamped Inverter for the Grid-Tied Photovoltaic Power Generation
    Gao, Feng
    Ge, Xuefeng
    Wang, Jianbo
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 547 - 553
  • [9] Control of Grid-tied Photovoltaic Systems with Neutral Point Clamped Inverters
    Osorio, Fausto
    Motta, Diego F.
    Mantilla, Maria A.
    Barrero, Jaime G.
    Petit, Johann F.
    2017 IEEE WORKSHOP ON POWER ELECTRONICS AND POWER QUALITY APPLICATIONS (PEPQA), 2017, : 171 - 176
  • [10] Neutral-point-clamped inverter with parallel driving of IGBT's for industrial applications
    Miyazaki, H
    Fukumoto, H
    Sugiyama, S
    Tachikawa, M
    Azusawa, N
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (01) : 146 - 151