Capillary electrophoresis; Capacitively coupled conductivity detection; Genuine nerve agents; Aqueous extraction; CHEMICAL WARFARE AGENTS; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; INDUCED FLUORESCENCE DETECTION; FLAME PHOTOMETRIC DETECTION; AMPLIFIED SAMPLE STACKING; DEGRADATION-PRODUCTS; ALKYLPHOSPHONIC ACIDS; LIQUID-CHROMATOGRAPHY; METHYLPHOSPHONIC ACID; ELECTROOSMOTIC FLOW;
D O I
10.1016/j.chroma.2011.03.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid, efficient and robust methods for sampling and extracting genuine nerve agents sarin, soman and VX were developed for analyzing these compounds on various solid matrices, such as concrete, tile, soil and vegetation. A portable capillary electrophoretic (CE) system with contactless conductometric detection was used for the in situ analysis of the extracted samples. A 7.5 mM MES/HIS-based separation electrolyte accomplished the analysis of target analytes in less than 5 min. The overall duration of the process including instrument start-up, sample extraction and analysis was less than 10 min, which is the fastest screening of nerve agents achieved with liquid phase separation methods to date. The procedure can easily be performed by a person in a protective suit and is therefore suitable for real-life applications. The CE results were validated by an independent GC-MS method and a satisfactory correlation was obtained. The use of a proper sampling strategy with two internal standards and "smart" data-processing software can overcome the low reproducibility of CE. This has a significant impact on the potential acceptance of portable CE instrumentation for the detection and analysis of genuine chemical warfare agents (CWA). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2618 / 2625
页数:8
相关论文
共 56 条
[1]  
BLACK G, 1993, GENAQ IRAQ ANFAL CAM, P271
[2]  
BUDAVARI S, 1989, MERCK INDEX, P594
[3]   SEPARATION OF SULFUR-CONTAINING CHEMICAL WARFARE RELATED-COMPOUNDS IN AQUEOUS SAMPLES BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
CHEICANTE, RL ;
STUFF, JR ;
DURST, HD .
JOURNAL OF CHROMATOGRAPHY A, 1995, 711 (02) :347-352
[4]   Separation of thiol and cyanide hydrolysis products of chemical warfare agents by capillary electrophoresis [J].
Copper, CL ;
Collins, GE .
ELECTROPHORESIS, 2004, 25 (06) :897-902
[5]   Packed capillary liquid chromatography-electrospray mass spectrometry analysis of organophosphorus chemical warfare agents [J].
D'Agostino, PA ;
Hancock, JR ;
Provost, LR .
JOURNAL OF CHROMATOGRAPHY A, 1999, 840 (02) :289-294
[6]   Determination of sarin, soman and their hydrolysis products in soil by packed capillary liquid chromatography-electrospray mass spectrometry [J].
D'Agostino, PA ;
Hancock, JR ;
Provost, LR .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (02) :291-299
[7]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[8]   Capillary gas chromatographic analysis of nerve agents using large volume injections [J].
DegenhardtLangelaan, CEAM ;
Kientz, CE .
JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (01) :210-214
[9]  
*DEP HOM SEC, 2007, GUID SEL CHEM DET EQ
[10]   Poly(dimethylsiloxane) microchip electrophoresis with contactless conductivity detection for measurement of chemical warfare agent degradation products [J].
Ding, Yongsheng ;
Garcia, Carlos D. ;
Rogers, Kim R. .
ANALYTICAL LETTERS, 2008, 41 (02) :335-350