Precision of orthognathic digital plan transfer using patient-specific cutting guides and osteosynthesis versus mixed analogue-digitally planned surgery: a randomized controlled clinical trial

被引:46
作者
Hanafy, M. [1 ]
Akoush, Y. [1 ]
Abou-ElFetouh, A. [1 ]
Mounir, R. M. [1 ]
机构
[1] Cairo Univ, Fac Dent, Oral & Maxillofacial Surg, 11 Saraya St, Cairo, Egypt
关键词
CAD/CAM; orthognathic; accuracy; plan transfer; patient-specific osteosynthesis; 3D planning; waterless maxillary positioning; FACE-BOW TRANSFER; COMPUTER-AIDED-DESIGN; SURGICAL SIMULATION; MODEL SURGERY; ACCURACY; SPLINT; PREDICTION; NAVIGATION; PROTOCOL; MAXILLA;
D O I
10.1016/j.ijom.2019.06.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Over the last decade, the accuracy of three-dimensional computer-assisted orthognathic surgery has been investigated extensively. The absence of high-quality controlled trials, limited number of studies overall, and methodological flaws have hindered its use in general clinical practice. The aim of this study was to assess the accuracy of computer-assisted orthognathic surgery compared to the classic occlusal wafers. Eighteen patients were randomly allocated to two groups: CAD/CAM splints and patient-specific osteosynthesis were used for maxillary positioning in group 1; occlusal wafers fabricated on a semi-adjustable articulator were used in group 2. Patients were assessed for linear and angular deviations of maxillary position from the virtual plan using cone beam computed tomography scans. The CAD/CAM group showed mean deviations of 0.26 mm vertically, 0.17 mm anteroposteriorly, and 0.07 mm mediolaterally, while the classic wafer group showed mean deviations of 1.45 mm vertically, 1.31 mm anteroposteriorly, and 0.71 mm mediolaterally. Statistical analysis showed that the proposed workflow provided a significantly more accurate plan transfer compared to classic occlusal wafers. Despite the statistical significance, the clinical significance was less appreciated. However, this new technology facilitated cases with skeletal asymmetry, reduced operating times, and allowed a trainee surgeon to perform the procedure with great accuracy and minimal time. The main limitation was the high cost.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 28 条
[1]   3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - Our experience in 16 cases [J].
Aboul-Hosn Centenero, Samir ;
Hernandez-Alfaro, Federico .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (02) :162-168
[2]   Errors in orthognathic surgery planning: the effect of inaccurate study model orientation [J].
Barbenel, J. C. ;
Paul, P. E. ;
Khambay, B. S. ;
Walker, F. S. ;
Moos, K. F. ;
Ayoub, A. F. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (11) :1103-1108
[3]   Computer-Assisted Piezoelectric Surgery: A Navigated Approach Toward Performance of Craniomaxillofacial Osteotomies [J].
Bianchi, Alberto ;
Badiali, Giovanni ;
Piersanti, Luigi ;
Marchetti, Claudio .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) :867-872
[4]   Three-dimensional surgical simulation [J].
Cevidanes, Lucia H. C. ;
Tucker, Scott ;
Styner, Martin ;
Kim, Hyungmin ;
Chapuis, Jonas ;
Reyes, Mauricio ;
Proffit, William ;
Turvey, Timothy ;
Jaskolka, Michael .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (03) :361-371
[5]   Computer-assisted orthognathic surgery for correction of facial asymmetry: results of a randomised controlled clinical trial [J].
De Riu, Giacomo ;
Meloni, Silvio Mario ;
Baj, Alessandro ;
Corda, Andrea ;
Soma, Damiano ;
Tullio, Antonio .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (03) :251-257
[6]   Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature [J].
De Vos, W. ;
Casselman, J. ;
Swennen, G. R. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) :609-625
[8]   ACCURACY OF FACE-BOW TRANSFER - EFFECT ON SURGICAL PREDICTION AND POSTSURGICAL RESULT [J].
ELLIS, E ;
THARANON, W ;
GAMBRELL, K .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (06) :562-567
[9]   Splint less orthognathic surgery: A novel technique using patient-specific implants (PSI) [J].
Gander, Thomas ;
Bredell, Marius ;
Eliades, Theodore ;
Ruecker, Martin ;
Essig, Harald .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (03) :319-322
[10]   A comparison of 3 methods of face-bow transfer recording: Implications for orthognathic surgery [J].
Gateno, J ;
Forrest, KK ;
Camp, B .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (06) :635-640