An Investigation of the Influences of the Voltage Sag on the Doubly Fed Induction Generator using Tuned PI Controllers

被引:3
作者
Rafiee, Zahra [1 ]
Rafiee, Mansour [1 ]
Aghamohammadi, Mohammadreza [1 ]
机构
[1] Sahid Beheshti Univ, Fac Elect Engn, Blv Daneshjoo, Tehran 1983969411, Iran
来源
TEHNICKI VJESNIK-TECHNICAL GAZETTE | 2020年 / 27卷 / 01期
关键词
doubly fed induction generator; fault ride through; low voltage ride through; voltage sags; ENHANCING LVRT CAPABILITY; FAULT RIDE-THROUGH; WIND; SYSTEM; ENHANCEMENT; PERFORMANCE; CIRCUIT;
D O I
10.17559/TV-20180813193720
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents dynamic and transient behavior of the doubly fed induction generator (DFIG) in the wind farms in the normal and faulted grid respectively. When Voltage sag or any fault occurs in the network, the variables in the Doubly Fed Induction Generators are varying severely. If a voltage sag occurs, active and reactive power generated by the DFIG start to oscillate. The DC-link voltage will be bigger and will have fluctuation, and the rotor current will increase. In this paper, proportional integral (PI) controllers are used to control the DFIG in the wind farms for driving of the electronic devices including Rotor Side Converter (RSC) and Grid Side Converter (GSC) and controlling the active and reactive power of DFIG. PI parameters are tuned by particle swarm optimization algorithm (PSO). Whereas the model of DFIGs and electronic device in the paper are nonlinear so PI controllers cannot protect and control the DFIG as well. Hence, effect of PI parameters is investigated on the DFIG with simulating in MATLAB software. Also, low voltage ride through (LVRT) feature for DFIG is explored in presence of PI controllers. The results of the simulation present DC-link over voltage and rotor and stator over current in the DFIG. In addition, it will explore the effect of proportional integral controllers when three-phase short circuit fault Occurs.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 35 条
[1]  
Abedi N., 2013, P AUSTR TRANS RES FO, P1
[2]  
[Anonymous], POW ENG C AUPEC 2013
[3]   Robust nonlinear controller design of wind turbine with doubly fed induction generator by using Hamiltonian energy approach [J].
Wang B. ;
Qian Y. ;
Zhang Y. .
Journal of Control Theory and Applications, 2013, 11 (02) :282-287
[4]   Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm [J].
Dosoglu, M. Kenan .
NONLINEAR DYNAMICS, 2017, 89 (04) :2683-2694
[5]   Enhancement of SDRU and RCC for low voltage ride through capability in DFIG based wind farm [J].
Dosoglu, M. Kenan .
ELECTRICAL ENGINEERING, 2017, 99 (02) :673-683
[6]   A new approach for low voltage ride through capability in DFIG based wind farm [J].
Dosoglu, M. Kenan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 :251-258
[7]   Hybrid low voltage ride through enhancement for transient stability capability in wind farms [J].
Dosoglu, M. Kenan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 :655-662
[8]   Robust Fuzzy Gains Scheduling of RST Controller for a WECS Based on a Doubly-Fed Induction Generator [J].
Doumi, M'Hamed ;
Aissaoui, Abdel Ghani ;
Abid, Mohamed ;
Tahour, Ahmed ;
Tahir, Khalfallah .
AUTOMATIKA, 2016, 57 (03) :617-626
[9]  
Eberhart R., 1995, 6 INT S MICR HUM SCI, P39, DOI DOI 10.1109/MHS.1995.494215
[10]   An improved low-voltage ride-through performance of DFIG based wind plant using stator dynamic composite fault current limiter [J].
Gayen, P. K. ;
Chatterjee, D. ;
Goswami, S. K. .
ISA TRANSACTIONS, 2016, 62 :333-348