Corneal power measurement with Fourier-domain optical coherence tomography

被引:87
作者
Tang, Maolong [1 ]
Chen, Alex [2 ]
Li, Yan [1 ]
Huang, David [1 ]
机构
[1] Doheny Eye Inst, Ctr Ophthalm Opt & Lasers, Los Angeles, CA 90033 USA
[2] Optovue Inc, Fremont, CA USA
基金
美国国家卫生研究院;
关键词
INTRAOCULAR-LENS POWER; PHOTOREFRACTIVE KERATECTOMY; CATARACT-SURGERY; PENTACAM; ORBSCAN; REPRODUCIBILITY; REPEATABILITY; RELIABILITY; AGREEMENT; ACCURACY;
D O I
10.1016/j.jcrs.2010.07.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the accuracy and repeatability of anterior, posterior, and net corneal power measured by Fourier-domain optical coherence tomography (OCT). SETTING: Doheny Eye Institute, Los Angeles, California, USA. DESIGN: Cross-sectional study. METHODS: A Fourier-domain OCT system (RTVue) was used to scan normal eyes, eyes after myopic laser in situ keratomileusis (LASIK), and keratoconic eyes. After the corneal surfaces were delineated, the system calculated anterior and posterior corneal powers by curve fitting over the central 3.0 mm diameter area. Net corneal power was calculated using a thick-lens formula. The repeatability of the calculations was evaluated by the pooled standard deviation of 3 measurements from the same visit. The net corneal power values were compared with standard automated keratometry measurements (IOLMaster). RESULTS: The repeatability of Fourier-domain OCT net corneal power was 0.19 diopters (D), 0.26 D, and 0.30 D in the normal, post-LASIK, and keratoconus groups, respectively. The Fourier-domain OCT net corneal power was significantly lower than keratometry by a mean of -1.21 D, -2.89 D, and -3.07 D, respectively (P<.001). The anterior posterior curvature ratio was lower in post-LASIK and keratoconic eyes than in normal eyes (P<.001). CONCLUSIONS: Corneal power measured by Fourier-domain OCT achieved good repeatability in all 3 groups. The repeatability was better than slower time-domain OCT systems. Because Fourier-domain OCT directly measures both anterior and posterior corneal surfaces, it may produce more consistent results than standard keratometry in post-LASIK and keratoconic eyes in which the anterior posterior corneal curvature ratios are altered by surgery or disease.
引用
收藏
页码:2115 / 2122
页数:8
相关论文
共 24 条
[1]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Accuracy of Orbscan optical pachymetry in corneas with haze [J].
Boscia, F ;
La Tegola, MG ;
Alessio, G ;
Sborgia, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :253-258
[4]   Reliability and repeatability of the Pentacam on corneal curvatures [J].
Chen, Davie ;
Lam, Andrew K. C. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (02) :110-118
[5]   A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis [J].
Hamed, AH ;
Wang, L ;
Misra, M ;
Koch, DD .
OPHTHALMOLOGY, 2002, 109 (04) :651-658
[6]   REPRODUCIBILITY OF NORMAL CORNEAL POWER MEASUREMENTS WITH A KERATOMETER, PHOTOKERATOSCOPE, AND VIDEO IMAGING-SYSTEM [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (04) :539-544
[7]   High-speed optical coherence tomography of corneal opacities [J].
Khurana, Rahul N. ;
Li, Yan ;
Tang, Maolong ;
Lai, Michael M. ;
Huang, David .
OPHTHALMOLOGY, 2007, 114 (07) :1278-1285
[8]  
Kim SW, 2007, J REFRACT SURG, V23, P888
[9]   PHOTOREFRACTIVE KERATECTOMY - A TECHNIQUE FOR LASER REFRACTIVE SURGERY [J].
MUNNERLYN, CR ;
KOONS, SJ ;
MARSHALL, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :46-52
[10]   Pentacam keratometry and IOL power calculation [J].
Norrby, Sverker .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) :3-3