Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis

被引:159
作者
Risby, Terence H. [1 ]
Tittel, Frank K. [2 ]
机构
[1] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Dept Environm Hlth Sci, Baltimore, MD 21205 USA
[2] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
基金
美国国家科学基金会; 美国国家航空航天局;
关键词
midinfrared semiconductor-laser-based chemical sensor; real-time breath analysis; breath sampling; quantum cascade lasers; interband cascade lasers; single-frequency; tunable external cavity quantum cascade/interband lasers; ENHANCED PHOTOACOUSTIC-SPECTROSCOPY; CAVITY OUTPUT SPECTROSCOPY; TUNABLE DIODE-LASER; NITRIC-OXIDE; ABSORPTION-SPECTROSCOPY; BROAD-BAND; RING-DOWN; QUANTITATIVE-ANALYSIS; AMMONIA DETECTION; GAS-DETECTION;
D O I
10.1117/1.3498768
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
State-of-the-art quantum-and interband-cascade-based chemical sensors may be effective new tools for the identification and quantification of trace gases in human breath for clinical uses. Increased or decreased concentrations of these molecules are associated with the pathogenesis of a large number of diseases. Current technologies enable breath analyses to be performed on a single breath and the results are available in real time. Critical parameters including sensor sensitivity, selectivity, real-time monitoring capability, robustness, cost, size, and weight determine the progress made toward the development and availability of commercial diagnostic material. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3498768]
引用
收藏
页数:14
相关论文
共 93 条
[1]   A DIFFERENTIAL DETECTION SCHEME FOR FARADAY-ROTATION SPECTROSCOPY WITH A COLOR CENTER LASER [J].
ADAMS, H ;
REINERT, D ;
KALKERT, P ;
URBAN, W .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1984, 34 (04) :179-185
[2]   ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005 [J].
American Thoracic Society ;
European Respiratory Society .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (08) :912-930
[3]  
[Anonymous], 1999, Am J Respir Crit Care Med, V160, P2104
[4]   PITUITARY GLANDS - ENZYMIC FORMATION OF METHANOL FROM S-ADENOSYLMETHIONINE [J].
AXELROD, J ;
DALY, J .
SCIENCE, 1965, 150 (3698) :892-&
[5]  
BAI Y, 2010, P SPIE, V7608
[6]  
BAKHIRKIN Y, 2007, SPIE OPT E SEP 9 12
[7]   Sub-ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy [J].
Bakhirkin, YA ;
Kosterev, AA ;
Curl, RF ;
Tittel, FK ;
Yarekha, DA ;
Hvozdara, L ;
Giovannini, M ;
Faist, J .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 82 (01) :149-154
[8]  
BARNETT D, 1969, CLIN SCI, V37, P570
[9]  
BORSON WF, 1994, HEPATOLOGY, V6, P502
[10]  
CHEN S, 1970, J LAB CLIN MED, V75, P628