Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment

被引:22
作者
Bhogal, Pervinder [1 ]
Petrov, Andrey [2 ]
Rentsenkhu, Ganbaatar [3 ]
Nota, Baatarjan [3 ]
Ganzorig, Erdenebat [3 ]
Regzengombo, Boldbat [3 ]
Jagusch, Sara [4 ]
Henkes, Elina [5 ]
Henkes, Hans [5 ,6 ]
机构
[1] Barts NHS Trust, Royal London Hosp, London, England
[2] Branch Natl Med Res Ctr Almazov, Russian Polenov Neurosurg Inst, Vasc Neurosurg Dept, St Petersburg, Russia
[3] Shastin Cent Hosp, Dept Angiog, Ulaanbaatar, Mongolia
[4] Phenox GmbH, Bochum, Germany
[5] Klinikum Stuttgart, Neuroradiol Clin, Kriegsbergstr 60, D-70174 Stuttgart, Germany
[6] Univ Duisburg Essen, Essen, Germany
关键词
p64 MW HPC; p48 MW HPC; single antiplatelet therapy; flow diverter; hydrophilic polymer coating; CEREBRAL-ARTERY ANEURYSMS; FLEX EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; SACCULAR ANEURYSMS; SHIELD TECHNOLOGY; DIVERSION; PIPELINE; STENTS; SAFETY;
D O I
10.1177/15910199211029503
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The p64MW HPC and p48MW HPC flow diverters have reduced thrombogenicity due to hydrophilic coating. The purpose of this study was to evaluate its safety and efficacy in Mongolian patients under single antiplatelet therapy (SAPT) with prasugrel. Materials and methods We performed a retrospective review of patients enrolled into our prospectively maintained database to identify all patients treated with either the p48MW HPC or p64MW HPC under SAPT. We recorded baseline demographics, aneurysm size and location, procedural complications, angiographic and clinical results. Results 24 patients, (female = 21, 87.5%), age 48.2 +/- 11.6 years (range 25-63) underwent treatment of 30 aneurysms with either p64MW HPC or p48MW HPC. All aneurysms were saccular with dome width 8.2 +/- 6.5 (range 1.6-26.0 mm) and dome height 7.6 +/- 6.7 (range 1.6-30.0 mm). None of the aneurysms were previously treated. The average PRU was 54.6 +/- 31.2 (range 1-127) on pre-operative VerifyNow testing. Angiographic follow-up was available for 13 patients (17 aneurysms), 183 +/- 36 days post-procedure, at which point 64.7% of aneurysms (n = 11/17) were completely occluded and 11.8% (n = 2/17) had only neck remnants resulting in 76.5% of aneurysms being adequately occluded A single intra-operative complication (4.2%) occurred however all patients were mRS <= 1 at last follow-up. There were two post-operative complications neither of which resulted in permanent neurological morbidity. There were no instances of post-operative aneurysmal rupture or delayed parenchymal haemorrhage. The overall mortality was 0%. Conclusion The efficacy and safety of p64MW HPC coated devices under SAPT is similar to uncoated flow diverters that require DAPT.
引用
收藏
页码:266 / 276
页数:11
相关论文
共 53 条
[31]   Flow-T stenting with the Silk Vista Baby and Baby Leo stents for bifurcation aneurysms - A novel endovascular technique [J].
Makalanda, H. L. D. ;
Wong, K. ;
Bhogal, P. .
INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (01) :68-73
[32]   Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience [J].
Manning, Nathan W. ;
Cheung, Andrew ;
Phillips, Timothy J. ;
Wenderoth, Jason D. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (07) :694-+
[33]   Periprocedural safety and technical outcomes of the new Silk Vista Baby flow diverter for the treatment of intracranial aneurysms: results from a multicenter experience [J].
Martinez-Galdamez, Mario ;
Biondi, Alessandra ;
Kalousek, Vladimir ;
Pereira, Vitor M. ;
Ianucci, Giuseppe ;
Gentric, Jean-Christophe ;
Mosimann, Pascal J. ;
Brisbois, Denis ;
Schob, Stefan ;
Quaeschling, Ulf ;
Kaesmacher, Johannes ;
Ognard, Julien ;
Escartin, Jorge ;
Tsang, Chun On Anderson ;
Culo, Branimir ;
Chabert, Emmanuel ;
Turjman, Francis ;
Barbier, Charlotte ;
Mihalea, Cristian ;
Spelle, Laurent ;
Chapot, Rene .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (07) :723-+
[34]   Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up [J].
Martinez-Galdamez, Mario ;
Lamin, Saleh M. ;
Lagios, Konstantinos G. ;
Liebig, Thomas ;
Ciceri, Elisa F. ;
Chapot, Rene ;
Stockx, Luc ;
Chavda, Swarupsinh ;
Kabbasch, Christoph ;
Farago, Giuseppe ;
Nordmeyer, Hannes ;
Boulanger, Thierry ;
Piano, Mariangela ;
Boccardi, Edoardo P. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) :396-399
[35]   Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study [J].
Martinez-Galdamez, Mario ;
Lamin, Saleh M. ;
Lagios, Konstantinos G. ;
Liebig, Thomas ;
Ciceri, Elisa F. ;
Chapot, Rene ;
Stockx, Luc ;
Chavda, Swarupsinh ;
Kabbasch, Christoph ;
Farago, Giuseppe ;
Nordmeyer, Hannes ;
Boulanger, Thierry ;
Piano, Mariangela ;
Boccardi, Edoardo P. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (08) :772-+
[36]   Multicenter Experience with FRED Jr Flow Re-Direction Endoluminal Device for Intracranial Aneurysms in Small Arteries [J].
Moehlenbruch, M. A. ;
Kizilkilic, O. ;
Killer-Oberpfalzer, M. ;
Baltacioglu, F. ;
Islak, C. ;
Bendszus, M. ;
Cekirge, S. ;
Saatci, I. ;
Kocer, N. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (10) :1959-1965
[37]   In vivo canine study of three different coatings applied to p64 flow-diverter stents: initial biocompatibility study [J].
Moreno, Rosa Martinez ;
Bhogal, Pervinder ;
Lenz-Habijan, Tim ;
Bannewitz, Catrin ;
Siddiqui, Adnan ;
Lylyk, Pedro ;
Hannes, Ralf ;
Monstadt, Hermann ;
Henkes, Hans .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) :3
[38]   The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial [J].
Nelson, P. K. ;
Lylyk, P. ;
Szikora, I. ;
Wetzel, S. G. ;
Wanke, I. ;
Fiorella, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :34-40
[39]   Experience using pipeline embolization device with Shield Technology in a patient lacking a full postoperative dual antiplatelet therapy regimen [J].
Orlov, Kirill ;
Kislitsin, Dmitry ;
Strelnikov, Nikolay ;
Berestov, Vadim ;
Gorbatykh, Anton ;
Shayakhmetov, Timur ;
Seleznev, Pavel ;
Tasenko, Anton .
INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (03) :270-273
[40]   Use of the pCONus HPC as an adjunct to coil occlusion of acutely ruptured aneurysms: early clinical experience using single antiplatelet therapy [J].
Perez, Marta Aguilar ;
AlMatter, Muhammad ;
Hellstern, Victoria ;
Wendl, Christina ;
Ganslandt, Oliver ;
Baezner, Hansjoerg ;
Henkes, Hans .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (09) :862-+