Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment

被引:22
作者
Bhogal, Pervinder [1 ]
Petrov, Andrey [2 ]
Rentsenkhu, Ganbaatar [3 ]
Nota, Baatarjan [3 ]
Ganzorig, Erdenebat [3 ]
Regzengombo, Boldbat [3 ]
Jagusch, Sara [4 ]
Henkes, Elina [5 ]
Henkes, Hans [5 ,6 ]
机构
[1] Barts NHS Trust, Royal London Hosp, London, England
[2] Branch Natl Med Res Ctr Almazov, Russian Polenov Neurosurg Inst, Vasc Neurosurg Dept, St Petersburg, Russia
[3] Shastin Cent Hosp, Dept Angiog, Ulaanbaatar, Mongolia
[4] Phenox GmbH, Bochum, Germany
[5] Klinikum Stuttgart, Neuroradiol Clin, Kriegsbergstr 60, D-70174 Stuttgart, Germany
[6] Univ Duisburg Essen, Essen, Germany
关键词
p64 MW HPC; p48 MW HPC; single antiplatelet therapy; flow diverter; hydrophilic polymer coating; CEREBRAL-ARTERY ANEURYSMS; FLEX EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; SACCULAR ANEURYSMS; SHIELD TECHNOLOGY; DIVERSION; PIPELINE; STENTS; SAFETY;
D O I
10.1177/15910199211029503
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The p64MW HPC and p48MW HPC flow diverters have reduced thrombogenicity due to hydrophilic coating. The purpose of this study was to evaluate its safety and efficacy in Mongolian patients under single antiplatelet therapy (SAPT) with prasugrel. Materials and methods We performed a retrospective review of patients enrolled into our prospectively maintained database to identify all patients treated with either the p48MW HPC or p64MW HPC under SAPT. We recorded baseline demographics, aneurysm size and location, procedural complications, angiographic and clinical results. Results 24 patients, (female = 21, 87.5%), age 48.2 +/- 11.6 years (range 25-63) underwent treatment of 30 aneurysms with either p64MW HPC or p48MW HPC. All aneurysms were saccular with dome width 8.2 +/- 6.5 (range 1.6-26.0 mm) and dome height 7.6 +/- 6.7 (range 1.6-30.0 mm). None of the aneurysms were previously treated. The average PRU was 54.6 +/- 31.2 (range 1-127) on pre-operative VerifyNow testing. Angiographic follow-up was available for 13 patients (17 aneurysms), 183 +/- 36 days post-procedure, at which point 64.7% of aneurysms (n = 11/17) were completely occluded and 11.8% (n = 2/17) had only neck remnants resulting in 76.5% of aneurysms being adequately occluded A single intra-operative complication (4.2%) occurred however all patients were mRS <= 1 at last follow-up. There were two post-operative complications neither of which resulted in permanent neurological morbidity. There were no instances of post-operative aneurysmal rupture or delayed parenchymal haemorrhage. The overall mortality was 0%. Conclusion The efficacy and safety of p64MW HPC coated devices under SAPT is similar to uncoated flow diverters that require DAPT.
引用
收藏
页码:266 / 276
页数:11
相关论文
共 53 条
[1]  
Abud TG, 2021, J NEUROINTERV SURG
[2]   The p48 Flow Modulation Device with Hydrophilic Polymer Coating (HPC) for the Treatment of Acutely Ruptured Aneurysms: Early Clinical Experience Using Single Antiplatelet Therapy [J].
Aguilar-Perez, Marta ;
Hellstern, Victoria ;
AlMatter, Muhammad ;
Wendl, Christina ;
Baezner, Hansjoerg ;
Ganslandt, Oliver ;
Henkes, Hans .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) :740-748
[3]   The p48 MW flow modulation device for treatment of unruptured, saccular intracranial aneurysms: a single center experience from 77 consecutive aneurysms [J].
AlMatter, Muhammad ;
Henkes, Elina ;
Sirakov, Alexander ;
Perez, Marta Aguilar ;
Hellstern, Victoria ;
Candel, Carmen Serna ;
Ganslandt, Oliver ;
Henkes, Hans .
CVIR ENDOVASCULAR, 2020, 3 (01)
[4]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[5]  
Behme D, 2021, AM J NEURORADIOL
[6]   The p48MW Flow Diverter-Initial Human Experience [J].
Bhogal, P. ;
Bleise, C. ;
Chudyk, J. ;
Lylyk, I ;
Viso, R. ;
Perez, N. ;
Henkes, H. ;
Lylyk, P. .
CLINICAL NEURORADIOLOGY, 2021, 31 (01) :135-145
[7]   Use of flow diverters in the treatment of unruptured saccular aneurysms of the anterior cerebral artery [J].
Bhogal, P. ;
Moreno, R. Martinez ;
Ganslandt, O. ;
Baezner, H. ;
Henkes, H. ;
Perez, M. Aguilar .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (03) :283-U78
[8]   Thrombogenicity of the p48 and anti-thrombogenic p48 hydrophilic polymer coating low-profile flow diverters in an in vitro human thrombin generation model [J].
Bhogal, Pervinder ;
Lenz-Habijan, Tim ;
Bannewitz, Catrin ;
Hannes, Ralf ;
Monstadt, Hermann ;
Brodde, Martin ;
Kehrel, Beate ;
Henkes, Hans .
INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (04) :488-493
[9]   The p48_HPC antithrombogenic flow diverter: initial human experience using single antiplatelet therapy [J].
Bhogal, Pervinder ;
Bleise, Carlos ;
Chudyk, Jorge ;
Lylyk, Ivan ;
Perez, Nicolas ;
Henkes, Hans ;
Lylyk, Pedro .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (01)
[10]   The Silk Vista Baby: Initial experience and report of two cases [J].
Bhogal, Pervinder ;
Wong, Ken ;
Uff, Christopher ;
Wadley, John ;
Makalanda, Hegoda L. D. .
INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (05) :530-538