Impedimetric immunosensor for atrazine detection using interdigitated μ-electrodes (IDμE's)

被引:50
作者
Valera, Enrique
Ramon-Azcon, Javier
Rodriguez, Angel
Castaner, Luis M.
Sanchez, F.-J.
Marco, M.-P.
机构
[1] Univ Politecn Cataluna, MNTg, Dept Elect Engn, ES-08034 Barcelona, Spain
[2] CSIC, IIQAB, AMRg, ES-08034 Barcelona, Spain
关键词
immunosensor; impedance spectroscopy; interdigitated mu-electrodes; atrazine;
D O I
10.1016/j.snb.2007.02.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel impedimetric inummosensor for atrazine detection, a widely used pesticide, is described. It is based on a two coplanar non-passivated interdigitated metallic mu-electrodes (1D mu E) and the differential measurement of the impedance frequency spectrum. No redox electrodes have been included in the sensor. The chemical recognition layer was deposited on top of the interdigitated mu-electrodes area (fingers and inter-digits space). Immunochemical detection of the atrazine concentration is achieved by a competitive reaction without using any label. Furthermore immunoreagents specifically developed to detect this pesticide have been used. The immunosensor and its functionalization steps have been characterized by means of chemical affinity methods and impedance spectroscopy. This work describes immunosensor development and its physico-chemical and analytical characterization. The inummosensor shows a limit of detection of 8.34 +/- 1.37 mu g L-1, which is lower than the Maximum Residue Level (MRL) (100 mu g L-1) established by EU (European Union) for residues of atrazine as herbicide in the wine grapes and other foodstuff products. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:526 / 537
页数:12
相关论文
共 52 条
[1]  
ALEGRET S, 2003, INTEGRATED ANAL SYST, V39, pCH1
[2]   Evaluation of a field-test kit for triazine herbicides (Se nsioScreen® TR500) as a fast assay to detect pesticide contamination in water samples [J].
Ballesteros, B ;
Barceló, D ;
Dankwardt, A ;
Schneider, P ;
Marco, MP .
ANALYTICA CHIMICA ACTA, 2003, 475 (1-2) :105-115
[3]   Influence of the hapten design on the development of a competitive ELISA for the determination of the antifouling agent Irgarol 1051 at trace levels [J].
Ballesteros, B ;
Barceló, D ;
Sanchez-Baeza, F ;
Camps, F ;
Marco, MP .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4004-4014
[4]  
BARD AJ, 2001, ELECTROCHEMICAL METH, P376
[5]   Oral valdecoxib and injected parecoxib for acute postoperative pain: A quantitative systematic review [J].
Jodie Barden ;
Jayne E Edwards ;
Henry J McQuay ;
R Andrew Moore .
BMC Anesthesiology, 3 (1)
[6]  
Barsoukov E, 2005, IMPEDANCE SPECTROSCOPY: THEORY, EXPERIMENT, AND APPLICATIONS, 2ND EDITION, pXII
[7]   On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy [J].
Bart, M ;
Stigter, ECA ;
Stapert, HR ;
de Jong, GJ ;
van Bennekom, WP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :49-59
[8]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[9]   Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine [J].
Biagini, RE ;
Smith, JP ;
Sammons, DL ;
MacKenzie, BA ;
Striley, CAF ;
Robertson, SK ;
Snawder, JE .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) :368-374
[10]   REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION [J].
BIER, FF ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (02) :125-130