Time-domain optical coherence tomography with digital holographic microscopy

被引:80
作者
Massatsch, P
Charrière, F
Cuche, E
Marquet, P
Depeursinge, CD
机构
[1] Ecole Polytech Fed Lausanne, Imaging & Appl Opt Inst, CH-1015 Lausanne, Switzerland
[2] Inst Physiol, CH-1005 Lausanne, Switzerland
关键词
D O I
10.1364/AO.44.001806
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We show that digital holography can be combined easily with optical coherence tomography approach. Varying the reference path length is the means used to acquire a series of holograms at different depths, providing after reconstruction images of slices at different depths in the specimen thanks to the short-coherence length of light source. A metallic object, covered by a 150-mu m-thick onion cell, is imaged with high resolution. Applications in ophthalmology are shown: structures of the anterior eye, the cornea, and the iris, are studied on enucleated porcine eyes. Tomographic images of the iris border close to the pupil were obtained 165 mu m underneath the eye surface. (c) 2005 Optical Society of America.
引用
收藏
页码:1806 / 1812
页数:7
相关论文
共 21 条
[1]   Video-rate optical low-coherence reflectometry based on a linear smart detector array [J].
Bourquin, S ;
Monterosso, V ;
Seitz, P ;
Salathé, RP .
OPTICS LETTERS, 2000, 25 (02) :102-104
[2]  
CAMBER O, 1987, ACTA VET SCAND, V28, P127
[3]   Simultaneous amplitude-contrast and quantitative phase-contrast microscopy by numerical reconstruction of Fresnel off-axis holograms [J].
Cuche, E ;
Marquet, P ;
Depeursinge, C .
APPLIED OPTICS, 1999, 38 (34) :6994-7001
[4]   Optical tomography by means of a numerical low-coherence holographic technique [J].
Cuche, E ;
Poscio, P ;
Depeursinge, C .
JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1997, 28 (06) :260-264
[5]   Digital holography for quantitative phase-contrast imaging [J].
Cuche, E ;
Bevilacqua, F ;
Depeursinge, C .
OPTICS LETTERS, 1999, 24 (05) :291-293
[6]   Aperture apodization using cubic spline interpolation: application in digital holographic microscopy [J].
Cuche, E ;
Marquet, P ;
Depeursinge, C .
OPTICS COMMUNICATIONS, 2000, 182 (1-3) :59-69
[7]   Spatial filtering for zero-order and twin-image elimination in digital off-axis holography [J].
Cuche, E ;
Marquet, P ;
Depeursinge, C .
APPLIED OPTICS, 2000, 39 (23) :4070-4075
[8]   Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[9]   Ultrahigh-resolution full-field optical coherence tomography [J].
Dubois, A ;
Grieve, K ;
Moneron, G ;
Lecaque, R ;
Vabre, L ;
Boccara, C .
APPLIED OPTICS, 2004, 43 (14) :2874-2883
[10]   High-resolution full-field optical coherence tomography with a Linnik microscope [J].
Dubois, A ;
Vabre, L ;
Boccara, AC ;
Beaurepaire, E .
APPLIED OPTICS, 2002, 41 (04) :805-812