Carbon dioxide (CO2) capture: Absorption-desorption capabilities of 2-amino-2-methyl-1-propanol (AMP), piperazine (PZ) and monoethanolamine (MEA) tri-solvent blends

被引:127
作者
Nwaoha, Chikezie [1 ,2 ]
Saiwan, Chintana [1 ,2 ]
Tontiwachwuthikul, Paitoon [1 ,2 ,3 ]
Supap, Teeradet [2 ]
Rongwong, Wichitpan [2 ,3 ]
Idem, Raphael [1 ,2 ,3 ]
AL-Marri, Mohammed J. [3 ]
Benamor, Abdelbaki
机构
[1] Chulalongkorn Univ, Petr & Petrochem Coll, Bangkok 10330, Thailand
[2] Univ Regina, Fac Engn & Appl Sci, CETRI, Regina, SK S4S 0A2, Canada
[3] Qatar Univ, Gas Proc Ctr, Doha, Qatar
关键词
Carbon dioxide (CO2) capture; 2-Amino-2-methyl-l-propanol (AMP); Piperazine (PZ); Monoethanolamine (MEA); Cyclic capacity; Initial desorption rate; Heat duty; Initial absorption rate; Absorption capacity; AQUEOUS PIPERAZINE; PILOT-PLANT; FLUE-GAS; PERFORMANCE; SOLUBILITY; KINETICS; EQUILIBRIUM; MIXTURES;
D O I
10.1016/j.jngse.2016.06.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, highly concentrated tri-solvent blends containing 2-amino-2-methyl-1-propanol (AMP), piperazine (PZ) and monoethanolamine (MEA) were experimentally investigated for their potential capabilities in carbon dioxide (CO2) capture. The concentration of both AMP and PZ were varied but their combined concentration (AMP PZ) was kept at 3 kmol/m(3) to limit the possibility of precipitation, the maximum PZ concentration (1.5 kmol/m(3)), and the total aqueous amine solution concentration (6 kmol/m(3)). At atmospheric pressure condition, the absorption process was carried out at 313 K and 15.1%v/v CO2 while 363 K was used for the desorption analysis. Experimental results indicated that all the AMP PZ MEA tri-solvent blends possessed higher cyclic capacities, initial desorption rates, and lower heat duties (50-54.5%) compared to the standard 5 kmol/m(3) MEA. For the initial absorption rates, only the tri-solvent blends with AMP/PZ molar ratios of 1 and 2 were higher than 5 kmol/m(3) MEA. These findings, most especially the significant reduction in heat duty by halve reveal the prospects of AMP PZ MEA tri-solvent blends for CO2 capture applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 41 条
[1]   Separation of CO2 from flue gas:: A review [J].
Aaron, D ;
Tsouris, C .
SEPARATION SCIENCE AND TECHNOLOGY, 2005, 40 (1-3) :321-348
[2]   CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Schneiders, Leon H. J. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) :37-46
[3]  
Adeosun A., 2013, RES INVENTY INT J EN, V3, P12
[4]  
[Anonymous], 2014, CO2 Emissions from Fuel Combustion
[5]  
[Anonymous], THESIS
[6]   CO2 capture solvent selection by combined absorption-desorption analysis [J].
Aronu, Ugochukwu E. ;
Hoff, Karl A. ;
Svendsen, Hallvara F. .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (8A) :1197-1203
[7]   Solubility of CO2 in an Aqueous Blend of Diethanolamine and Trisodium Phosphate [J].
Balsora, Hemant K. ;
Mondal, Monoj K. .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2011, 56 (12) :4691-4695
[8]   Absorption of carbon dioxide into aqueous piperazine: reaction kinetics, mass transfer and solubility [J].
Bishnoi, S ;
Rochelle, GT .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (22) :5531-5543
[9]  
Bishnoi S., 2000, ENERGY OUTLOOK 2035
[10]   CO2 capture into aqueous solutions of piperazine activated 2-amino-2-methyl-1-propanol [J].
Bruder, Peter ;
Grimstvedt, Andreas ;
Mejdell, Thor ;
Svendsen, Hallvard F. .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (23) :6193-6198