General Strategy for Performing Temperature Programming in High Performance Liquid Chromatography: Prediction of Linear Temperature Gradients

被引:17
作者
Wiese, Steffen [1 ,2 ]
Teutenberg, Thorsten [1 ]
Schmidt, Torsten C. [2 ]
机构
[1] Inst Energie & Umwelttech eV, D-47229 Duisburg, Germany
[2] Univ Duisburg Gesamthsch, D-45141 Essen, Germany
关键词
REVERSED-PHASE SYSTEMS; COMPUTER-SIMULATION; GAS-CHROMATOGRAPHY; MOBILE-PHASE; MASS-SPECTROMETRY; PH-STABILITY; SEPARATION; ELUTION; COLUMN; HPLC;
D O I
10.1021/ac103113m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes how an empirical retention model is transferred from temperature-programmed gas chromatography (GC) to high temperature liquid chromatography (HT-HPLC). In order to evaluate the retention prediction, a temperature range from 50 to 180 degrees C was investigated using two test mixtures consisting of steroids and polycyclic aromatic hydrocarbons. In this temperature range, heating rates from 1.5 degrees C min(-1) up to 30 degrees C min(-1) were applied using four different high temperature stable HPLC columns with inner diameters of 1.0, 2.1, 3.0, and 4.6 mm. Temperature lag phenomena in the HPLC column as well as in the column oven are discussed, and it is shown that the linear elution strength (LES) model can be applied without any mathematical extension in order to take a temperature-dependent delay time into account. On the basis of this approximation, it is possible to perform a systematic method development using linear temperature gradients in liquid chromatography. Furthermore, it is shown that only two initial temperature gradient runs are necessary to predict the retention times of the analytes with a maximal relative error of less than 2%.
引用
收藏
页码:2227 / 2233
页数:7
相关论文
共 43 条
  • [1] COMPUTER-SIMULATION (BASED ON A LINEAR-ELUTION-STRENGTH APPROXIMATION) AS AN AID FOR OPTIMIZING SEPARATIONS BY PROGRAMMED-TEMPERATURE GAS-CHROMATOGRAPHY
    BAUTZ, DE
    DOLAN, JW
    RADDATZ, WD
    SNYDER, LR
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (15) : 1560 - 1567
  • [2] COMPUTER-SIMULATION AS AN AID IN METHOD DEVELOPMENT FOR GAS-CHROMATOGRAPHY .1. THE ACCURATE PREDICTION OF SEPARATION AS A FUNCTION OF EXPERIMENTAL CONDITIONS
    BAUTZ, DE
    DOLAN, JW
    SNYDER, LR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2): : 1 - 19
  • [3] Towards a solution for viscous heating in ultra-high pressure liquid chromatography using intermediate cooling
    Broeckhoven, K.
    Billen, J.
    Verstraeten, M.
    Choikhet, K.
    Dittmann, M.
    Rozing, G.
    Desmet, G.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (13) : 2022 - 2031
  • [4] Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions
    Cabooter, Deirdre
    Lestremau, Francois
    de Villiers, Andre
    Broeckhoven, Ken
    Lynen, Frederic
    Sandra, Pat
    Desmet, Gert
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3895 - 3903
  • [5] High-temperature liquid chromatography coupled on-line to a continuous-flow biochemical screening assay with electrospray ionization mass spectrometric detection
    de Boer, AR
    Alcaide-Hidalgo, JM
    Krabbe, JG
    Kolkman, J
    Boas, CNV
    Niessen, WMA
    Lingeman, H
    Irth, H
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (24) : 7894 - 7900
  • [6] Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development - II. The use of further changes in conditions
    Dolan, JW
    Snyder, LR
    Saunders, DL
    Van Heukelem, L
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) : 33 - 50
  • [7] GRADIENT ELUTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. PRACTICAL APPLICATION TO REVERSED-PHASE SYSTEMS
    DOLAN, JW
    GANT, JR
    SNYDER, LR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 165 (01): : 31 - 58
  • [8] COMPUTER-SIMULATION AS A MEANS OF DEVELOPING AN OPTIMIZED REVERSED-PHASE GRADIENT-ELUTION SEPARATION
    DOLAN, JW
    SNYDER, LR
    QUARRY, MA
    [J]. CHROMATOGRAPHIA, 1987, 24 : 261 - 276
  • [9] Variability of column selectivity for reversed-phase high-performance liquid chromatography - Compensation by adjustment of separation conditions
    Dolan, JW
    Snyder, LR
    Jupille, TH
    Wilson, NS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) : 51 - 67
  • [10] COMPUTER-SIMULATION AS AN AID IN METHOD DEVELOPMENT FOR GAS-CHROMATOGRAPHY .2. CHANGES IN BAND SPACING AS A FUNCTION OF TEMPERATURE
    DOLAN, JW
    SNYDER, LR
    BAUTZ, DE
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2): : 21 - 34