Model for Predicting DC Flashover Voltage of Pre-Contaminated and Ice-Covered Long Insulator Strings under Low Air Pressure

被引:11
作者
Hu, Jianlin [1 ]
Sun, Caixin [1 ]
Jiang, Xingliang [1 ]
Yang, Qing [1 ]
Zhang, Zhijin [1 ]
Shu, Lichun [1 ]
机构
[1] Chongqing Univ, Coll Elect Engn, State Key Lab Power Transmiss Equipments & Syst S, Chongqing 400044, Peoples R China
关键词
ice-covered insulator string; flashover; mathematical model; DC; low air pressure; pre-contamination; ARC-DISCHARGE; AC; PERFORMANCE; PROPAGATION; SNOW;
D O I
10.3390/en4040628
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the current study, a multi-arc predicting model for DC critical flashover voltage of iced and pre-contaminated long insulator strings under low atmospheric pressure is developed. The model is composed of a series of different polarity surface arcs, icicle-icicle air gap arcs, and residual layer resistance. The calculation method of the residual resistance of the ice layer under DC multi-arc condition is established. To validate the model, 7-unit and 15-unit insulator strings were tested in a multi-function artificial climate chamber under the coexistent conditions of low air pressure, pollution, and icing. The test results showed that the values calculated by the model satisfactorily agreed with those experimentally measured, with the errors within the range of 10%, validating the rationality of the model.
引用
收藏
页码:628 / 643
页数:16
相关论文
共 32 条
[1]  
[Anonymous], 1991, International Standard IEC, V507
[2]   FLASHOVER PERFORMANCE OF ARTIFICIALLY CONTAMINATED AND ICED LONG-ROD TRANSMISSION-LINE INSULATORS [J].
CHERNEY, EA .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (01) :46-52
[3]   DC characteristics of local arc on ice surfaces [J].
Farzaneh, M ;
Zhang, J ;
Chen, X .
ATMOSPHERIC RESEARCH, 1998, 46 (1-2) :49-56
[4]   AC FLASHOVER PERFORMANCE OF INSULATORS COVERED WITH ARTIFICIAL ICE [J].
FARZANEH, M ;
DRAPEAU, JF .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) :1038-1051
[5]   Insulator icing test methods and procedures a position paper prepared by the IEEE task force on insulator icing test methods [J].
Farzaneh, M ;
Baker, T ;
Bernstorf, A ;
Brown, K ;
Chisholm, WA ;
de Tourreil, C ;
Drapeau, JF ;
Fikke, S ;
George, JM ;
Gnandt, E ;
Grisham, T ;
Gutman, I ;
Hartings, R ;
Kremer, R ;
Powell, G ;
Rolfseng, L ;
Rozek, T ;
Ruff, DL ;
Shaffner, D ;
Sklenicka, V ;
Sundararajan, R ;
Yu, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) :1503-1515
[6]   Modeling of the ac arc discharge on ice surfaces [J].
Farzaneh, M ;
Zhang, J ;
Chen, X .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :325-338
[7]   A multi-arc model for predicting AC critical flashover voltage of lee-covered insulators [J].
Farzaneh, M. ;
Zhang, J. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1401-1409
[8]   Effects of low air pressure on ac and dc arc propagation on ice surface [J].
Farzaneh, M ;
Zhang, J ;
Li, Y .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (01) :60-71
[9]   FLASHOVER PROBLEMS CAUSED BY ICE BUILDUP ON INSULATORS [J].
FARZANEH, M ;
KIERNICKI, J .
IEEE ELECTRICAL INSULATION MAGAZINE, 1995, 11 (02) :5-17
[10]   Flashover performance of IEEE standard insulators under ice conditions [J].
Farzaneh, M ;
Kiernicki, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) :1602-1613