A method based on liquid-liquid extraction (LLE) and automated large volume injection (LVI)GC-MS analysis was developed for the trace determination of phthalate di-esters in water samples at sub-mu g L-1 (ppb) levels. Strategies applied to reduce contamination include (i) careful selection of tools, glassware and solvents, (ii) systematic blank checks of the chromatographic system, glassware and solvents and (iii) frequent verifications of blanks during sequences. Background levels could be reduced to those present in the extraction solvent. For phthalates not present in the extraction solvent the limits of quantitation (LOQ) are 6 ng L-1 for di-methyl phthalate (DMP), 3 ng L-1 for benzylbutyl phthalate (BzBP) and 45 ng L-1 for the isomeric phthalate mixtures di-isononyl phthalate (DiNP) and di-isodecyl phthalate (DOP). For the other phthalates, the LOQ was set at twice the blank (extraction solvent) level and are 20 ng L-1 for di-ethyl phthalate (DEP), 60 ng L-1 for di-isobutyl phthalate (DiBP), 80 ng L-1 for di-n-butyl phthalate (DBP) and 30 ng L-1 for bis-(2-ethylhexyl) phthalate (DEHP).
引用
收藏
页码:365 / 370
页数:6
相关论文
共 20 条
[1]  
Bärwinkel D, 2000, DEUT LEBENSM-RUNDSCH, V96, P411
[2]   Determination of endocrine disruptors in environmental water samples by stir bar sorptive extraction-liquid desorption -: Large volume injection-gas chromatography [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
CHROMATOGRAPHIA, 2005, 61 (1-2) :61-65
[3]   Characterisation of organic pollutants in textile wastewaters and landfill leachate by using toxicity-based fractionation methods followed by liquid and gas chromatography coupled to mass spectrometric detection [J].
Castillo, M ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 2001, 426 (02) :253-264
[4]   High-throughput analysis of phthalate esters in human serum by direct immersion SPME followed by isotope dilution-fast GC/MS [J].
Colón, I ;
Dimandja, JMD .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (02) :275-283
[5]   PHTHALATES IN SURFACE-WATER - A METHOD FOR ROUTINE TRACE-LEVEL ANALYSIS [J].
FURTMANN, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (04) :291-296
[6]  
JONKER N, 1997, 703713007 RIVM
[8]   Determination of phthalate ester congeners and mixtures by LC/ESI-MS in sediments and biota of an urbanized marine inlet [J].
Lin, ZP ;
Ikonomou, MG ;
Jing, HW ;
Mackintosh, C ;
Gobas, FAPC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (10) :2100-2108
[9]  
LOPEZAVILA V, 1990, J ASSOC OFF ANA CHEM, V73, P709
[10]   Solid-phase microextraction of phthalates from water [J].
Luks-Betlej, K ;
Popp, P ;
Janoszka, B ;
Paschke, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :93-101