Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement

被引:80
|
作者
Neumann, FJ
Desmet, W
Grube, E
Brachmann, J
Presbitero, P
Rubartelli, P
Mügge, A
Di Pede, F
Füllgraf, D
Aengevaeren, W
Spedicato, L
Popma, JJ
机构
[1] Herz Zentrum Bad Krozingen, D-79189 Bad Krozingen, Germany
[2] Katholieke Univ Leuven Hosp, Dept Cardiol, Louvain, Belgium
[3] Krankenhaus Siegburg GmbH, Herzzentrum, Siegburg, Germany
[4] Klinikum Coburg, Coburg, Germany
[5] Ist Clin Humanitas, Rozzano, Italy
[6] Osped San Martino Genova, Genoa, Italy
[7] Ruhr Univ Bochum, St Josef Hosp, D-4630 Bochum, Germany
[8] Osped Civile Mestre, Venice, Italy
[9] Klinikum Ludenscheid, Ludenscheid, Germany
[10] Univ Med Ctr St Radboud, Nijmegen, Netherlands
[11] Osped S Maria Misericordia, Udine, Italy
[12] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
restenosis; sirolimus; stents;
D O I
10.1161/01.CIR.0000162467.53001.6B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. Methods and Results - The study was designed as a prospective multicenter registry. We included 162 patients with in-stent restenosis of a native coronary artery who had a clinical indication for repeat intervention. Patients were scheduled for follow-up angiography at 6 months. The primary end point was in-lesion late loss. Follow-up angiography was performed in 155 patients. We obtained an in-lesion late loss of 0.08 +/- 0.49 mm and a binary restenosis rate of 9.7% (15/155), which prompted reintervention in 7.4% (12/162) at 9 months. The 9-month rate of death was 1.2% (2/162) and that of nonfatal myocardial infarction was 1.2% (2/162). Conclusions - Sirolimus-eluting stents were highly efficacious and safe in the treatment of in-stent restenosis. Our study provides rationale for the use of sirolimus-eluting stents in the treatment of in-stent restenosis.
引用
收藏
页码:2107 / 2111
页数:5
相关论文
共 50 条
  • [41] Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) - Sirolimus-eluting stents inhibit restenosis irrespective of the vessel size
    Regar, E
    Serruys, PW
    Bode, C
    Holubarsch, C
    Guermonprez, JL
    Wijns, W
    Bartorelli, A
    Constantini, C
    Degertekin, M
    Tanabe, K
    Disco, C
    Wuelfert, E
    Morice, MC
    CIRCULATION, 2002, 106 (15) : 1949 - 1956
  • [42] Randomized comparison of sirolimus-eluting stent versus standard stent for percutaneous coronary revascularization in diabetic patients -: The diabetes and sirolimus-eluting stent (DIABETES) trial
    Sabaté, M
    Jiménez-Quevedo, P
    Angiolillo, DJ
    Gómez-Hospital, JA
    Alfonso, F
    Hernández-Antolín, R
    Goicolea, J
    Bañuelos, C
    Escaned, J
    Moreno, RL
    Fernández, C
    Fernández-Avilés, F
    Macaya, C
    CIRCULATION, 2005, 112 (14) : 2175 - 2183
  • [43] Revascularization of malignant coronary instent restenosis resulting from Takayasu's arteritis using sirolimus-eluting stents
    Sakai, Hidetsugu
    Oyama, Naotsugu
    Kishimoto, Noriaki
    Takahashi, Masashige
    Urasawa, Kazushi
    Tsutsui, Hiroyuki
    INTERNATIONAL HEART JOURNAL, 2006, 47 (05) : 795 - 801
  • [44] Intraprocedural stent thrombosis during implantation of sirolimus-eluting stents
    Chieffo, A
    Bonizzoni, E
    Orlic, D
    Stankovic, G
    Rogacka, R
    Airoldi, F
    Mikhail, GW
    Montorfano, M
    Michev, I
    Carlino, M
    Colombo, A
    CIRCULATION, 2004, 109 (22) : 2732 - 2736
  • [45] Clinical characteristics of stent fracture after sirolimus-eluting stent implantation
    Yang, Tae-Hyun
    Kim, Doo-Il
    Park, Seong-Gill
    Seo, Jeong-Sook
    Cho, Hwan-Jin
    Seol, Sang-Hoon
    Kim, Seong-Man
    Kim, Dae-Kyeong
    Kim, Dong-Soo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 131 (02) : 212 - 216
  • [46] Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    Aoki, Jiro
    Nakazawa, Gaku
    Tanabe, Kengo
    Hoye, Angela
    Yamamoto, Hirosada
    Nakayama, Tomohiro
    Onuma, Yoshinobu
    Higashikuni, Yasutomi
    Otsuki, Syuji
    Yagishita, Atsuhiko
    Yachi, Sen
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) : 380 - 386
  • [47] Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents
    Kastrati, A
    Dibra, A
    Mehilli, J
    Mayer, S
    Pinieck, S
    Pache, J
    Dirschinger, J
    Schöming, A
    CIRCULATION, 2006, 113 (19) : 2293 - 2300
  • [48] Safety and Efficacy of Everolimus-Eluting Stents Versus Sirolimus-Eluting Stents in Women
    Badr, Salem
    Barbash, Israel M.
    Pvir, Danny
    Torguson, Rebecca
    Xue, Zhenyi
    Kitabata, Hironori
    Sardi, Gabriel
    Loh, Joshua P.
    Pichard, Augusto D.
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (01) : 21 - 25
  • [49] Effects of sirolimus-eluting stent on calcified coronary lesions
    Jian-Jun, Li
    Bo, Xu
    Yue-Jin, Yang
    Ji-Lin, Chen
    Shu-Bing, Qiao
    Wei-Hua, Ma
    Xue-Wen, Qin
    Min, Yao
    Hai-Bo, Liu
    Yong-Jian, Wu
    Jin-Qing, Yuan
    Jue, Chen
    Shi-Jie, You
    Jun, Dai
    Ran, Xia
    Run-Lin, Gao
    CHINESE MEDICAL JOURNAL, 2008, 121 (01) : 6 - 11
  • [50] Long-term clinical outcomes after sirolimus-eluting Stent implantation for treatment of restenosis within bare-metal versus drug-eluting stents
    Lee, Cheol Whan
    Kim, Sang-Hyun
    Suh, Jon
    Park, Duk-Woo
    Lee, Seung-Hwan
    Kim, Young-Hak
    Hong, Myeong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (05) : 594 - 598