Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement

被引:80
|
作者
Neumann, FJ
Desmet, W
Grube, E
Brachmann, J
Presbitero, P
Rubartelli, P
Mügge, A
Di Pede, F
Füllgraf, D
Aengevaeren, W
Spedicato, L
Popma, JJ
机构
[1] Herz Zentrum Bad Krozingen, D-79189 Bad Krozingen, Germany
[2] Katholieke Univ Leuven Hosp, Dept Cardiol, Louvain, Belgium
[3] Krankenhaus Siegburg GmbH, Herzzentrum, Siegburg, Germany
[4] Klinikum Coburg, Coburg, Germany
[5] Ist Clin Humanitas, Rozzano, Italy
[6] Osped San Martino Genova, Genoa, Italy
[7] Ruhr Univ Bochum, St Josef Hosp, D-4630 Bochum, Germany
[8] Osped Civile Mestre, Venice, Italy
[9] Klinikum Ludenscheid, Ludenscheid, Germany
[10] Univ Med Ctr St Radboud, Nijmegen, Netherlands
[11] Osped S Maria Misericordia, Udine, Italy
[12] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
restenosis; sirolimus; stents;
D O I
10.1161/01.CIR.0000162467.53001.6B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. Methods and Results - The study was designed as a prospective multicenter registry. We included 162 patients with in-stent restenosis of a native coronary artery who had a clinical indication for repeat intervention. Patients were scheduled for follow-up angiography at 6 months. The primary end point was in-lesion late loss. Follow-up angiography was performed in 155 patients. We obtained an in-lesion late loss of 0.08 +/- 0.49 mm and a binary restenosis rate of 9.7% (15/155), which prompted reintervention in 7.4% (12/162) at 9 months. The 9-month rate of death was 1.2% (2/162) and that of nonfatal myocardial infarction was 1.2% (2/162). Conclusions - Sirolimus-eluting stents were highly efficacious and safe in the treatment of in-stent restenosis. Our study provides rationale for the use of sirolimus-eluting stents in the treatment of in-stent restenosis.
引用
收藏
页码:2107 / 2111
页数:5
相关论文
共 50 条
  • [21] Sirolimus-Eluting Stent Versus Balloon Angioplasty for Sirolimus-Eluting Stent Restenosis: Insights From the j-Cypher Registry
    Abe, Mitsuru
    Kimura, Takeshi
    Morimoto, Takeshi
    Taniguchi, Takuya
    Yamanaka, Futoshi
    Nakao, Kazuhiro
    Yagi, Nobuhito
    Kokubu, Nobuaki
    Kasahara, Yoichiro
    Kataoka, Yu
    Otsuka, Yoritaka
    Kawamura, Atsushi
    Miyazaki, Shunichi
    Nakao, Koichi
    Horiuchi, Kenji
    Ito, Akira
    Hoshizaki, Hiroshi
    Kawaguchi, Ren
    Setoguchi, Manabu
    Inada, Tsukasa
    Kishi, Koichi
    Sakamoto, Hiroki
    Morioka, Nobuyuki
    Imai, Masao
    Shiomi, Hiroki
    Nonogi, Hiroshi
    Mitsudo, Kazuaki
    CIRCULATION, 2010, 122 (01) : 42 - U89
  • [22] Significant Association of Coronary Artery Calcification in Stent Delivery Route With Restenosis After Sirolimus-Eluting Stent Implantation
    Mori, Shumpei
    Yasuda, Satoshi
    Kataoka, Yu
    Morii, Isao
    Kawamura, Atsushi
    Miyazaki, Shunichi
    CIRCULATION JOURNAL, 2009, 73 (10) : 1856 - 1863
  • [23] Is there delayed restenosis in patients with coronary artery disease treated with sirolimus-eluting stent?
    Li, Jian-Jun
    Xu, Bo
    Yang, Yue-Jin
    Chen, Ji-Lin
    Qiao, Shu-Bing
    Ma, Wei-Hua
    Qin, Xue-Wen
    Yao, Min
    Liu, Hai-Bo
    Wu, Yong-Jian
    Yuan, Jin-Qing
    Chen, Jue
    You, Shi-Jie
    Dai, Jun
    Xia, Ran
    Gao, Run-Lin
    CORONARY ARTERY DISEASE, 2007, 18 (04) : 293 - 298
  • [24] Effectiveness and safety of the sirolimus-eluting stents coated with bioabsorbable polymer coating in human coronary arteries
    Ge, Junbo
    Qian, Juying
    Wang, Xiangfei
    Wang, Qibing
    Yan, Wei
    Yan, Yan
    Fan, Bing
    Ge, Lei
    Liu, Xuebo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (02) : 198 - 202
  • [25] Sirolimus-eluting stent for the treatment of in-stent restenosis - A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    Sousa, JE
    Costa, MA
    Abizaid, A
    Sousa, AGMR
    Feres, F
    Mattos, LA
    Centemero, M
    Maldonado, G
    Abizaid, AS
    Pinto, I
    Falotico, R
    Jaeger, J
    Popma, JJ
    Serruys, PW
    CIRCULATION, 2003, 107 (01) : 24 - 27
  • [26] Impact of Hinge Motion on In-Stent Restenosis after Sirolimus-Eluting Stent Implantation
    Ino, Yasushi
    Kubo, Takashi
    Shimamura, Kunihiro
    Satogami, Keiryou
    Kitabata, Hironori
    Kimura, Keizo
    Hirata, Kumiko
    Komukai, Kenichi
    Tanimoto, Takashi
    Ishibashi, Kohei
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    CIRCULATION, 2010, 122 (21)
  • [27] Sirolimus-eluting stent for in-stent restenosis of left main coronary artery in Takayasu arteritis
    Furukawa, Y
    Tamura, T
    Toma, M
    Abe, M
    Saito, N
    Ehara, N
    Taniguchi, R
    Nakagawa, Y
    Kita, T
    Kimura, T
    CIRCULATION JOURNAL, 2005, 69 (06) : 752 - 755
  • [28] Treatment of Paclitaxel-Eluting Stent Restenosis With Sirolimus-Eluting Stent Implantation - Angiographic and Clinical Outcomes
    Byrne, Robert
    Iijima, Raisuke
    Mehilli, Julinda
    Pache, Juergen
    Schulz, Stefanie
    Schoemig, Albert
    Kastrati, Adnan
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (11): : 1134 - 1139
  • [29] Five-year clinical follow-up after sirolimus-eluting stent implantation for the treatment of coronary in-stent restenosis
    Schiele, Thomas M.
    Leibig, Marcus
    Rieber, Johannes
    Koenig, Andreas
    Kroetz, Florian
    Sohn, Hae-Young
    Klauss, Volker
    CORONARY ARTERY DISEASE, 2011, 22 (03) : 188 - 193
  • [30] Clinical and angiographic follow-up study of sirolimus-eluting stent for treatment of in-stent restenosis
    Liu, YW
    Liu, Q
    Pan, CM
    Jin, GL
    Luo, JF
    Xia, ZQ
    Ai, SZ
    Wang, FS
    CHINESE MEDICAL JOURNAL, 2005, 118 (05) : 429 - 432