Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement

被引:80
|
作者
Neumann, FJ
Desmet, W
Grube, E
Brachmann, J
Presbitero, P
Rubartelli, P
Mügge, A
Di Pede, F
Füllgraf, D
Aengevaeren, W
Spedicato, L
Popma, JJ
机构
[1] Herz Zentrum Bad Krozingen, D-79189 Bad Krozingen, Germany
[2] Katholieke Univ Leuven Hosp, Dept Cardiol, Louvain, Belgium
[3] Krankenhaus Siegburg GmbH, Herzzentrum, Siegburg, Germany
[4] Klinikum Coburg, Coburg, Germany
[5] Ist Clin Humanitas, Rozzano, Italy
[6] Osped San Martino Genova, Genoa, Italy
[7] Ruhr Univ Bochum, St Josef Hosp, D-4630 Bochum, Germany
[8] Osped Civile Mestre, Venice, Italy
[9] Klinikum Ludenscheid, Ludenscheid, Germany
[10] Univ Med Ctr St Radboud, Nijmegen, Netherlands
[11] Osped S Maria Misericordia, Udine, Italy
[12] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
restenosis; sirolimus; stents;
D O I
10.1161/01.CIR.0000162467.53001.6B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. Methods and Results - The study was designed as a prospective multicenter registry. We included 162 patients with in-stent restenosis of a native coronary artery who had a clinical indication for repeat intervention. Patients were scheduled for follow-up angiography at 6 months. The primary end point was in-lesion late loss. Follow-up angiography was performed in 155 patients. We obtained an in-lesion late loss of 0.08 +/- 0.49 mm and a binary restenosis rate of 9.7% (15/155), which prompted reintervention in 7.4% (12/162) at 9 months. The 9-month rate of death was 1.2% (2/162) and that of nonfatal myocardial infarction was 1.2% (2/162). Conclusions - Sirolimus-eluting stents were highly efficacious and safe in the treatment of in-stent restenosis. Our study provides rationale for the use of sirolimus-eluting stents in the treatment of in-stent restenosis.
引用
收藏
页码:2107 / 2111
页数:5
相关论文
共 50 条
  • [1] Everolimus versus sirolimus-eluting stents for the treatment of sirolimus-eluting stent restenosis
    Yan, Rong-Qiang
    Gao, Li-Jian
    Chen, Ji-Lin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 165 (03) : 568 - 569
  • [2] Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents
    Kim, Jung-Sun
    Lee, Seung-Yul
    Lee, Jung Myung
    Yoon, Young Won
    Ahn, Chul-Min
    Kim, Myung-Hyun
    Min, Pil-Ki
    Ko, Young-Guk
    Hong, Bum-Kee
    Choi, Donghoon
    Kwon, Hyuck Moon
    Jang, Yangsoo
    Shim, Won-Heum
    CORONARY ARTERY DISEASE, 2009, 20 (01) : 59 - 63
  • [3] Treatment of renal artery in-stent restenosis with sirolimus-eluting stents
    Kiernan, Thomas J.
    Yan, Bryan P.
    Eisenberg, Jonathan D.
    Ruggiero, Nicholas J.
    Gupta, Vishal
    Drachman, Douglas
    Schainfeld, Robert M.
    Jaff, Michael R.
    Rosenfield, Kenneth
    Garasic, Joseph
    VASCULAR MEDICINE, 2010, 15 (01) : 3 - 7
  • [4] Sirolimus-eluting coronary stent
    Vishnevetsky, D
    Patel, P
    Tijerino, H
    Gandhi, PJ
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (05) : 449 - 456
  • [5] Stent fracture: An unusual cause of late restenosis after sirolimus-eluting stent placement
    Mehrle, Anderson
    Skelton, Thomas
    Almonacid, Alexandra
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (07) : 989 - 992
  • [6] Sirolimus-eluting stents for treatment of in-stent restenosis -: Immediate and late results
    Medina, A
    de Lezo, JS
    Pan, M
    Delgado, A
    Segura, J
    Pavlovic, D
    Melián, F
    Romero, M
    Segura, F
    Hernández, E
    Ureña, I
    Herrador, J
    TEXAS HEART INSTITUTE JOURNAL, 2005, 32 (01): : 11 - 15
  • [7] Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries
    Popma, JJ
    Leon, MB
    Moses, JW
    Holmes, DR
    Cox, N
    Fitzpatrick, M
    Douglas, J
    Lambert, C
    Mooney, M
    Yakubov, S
    Kuntz, RE
    CIRCULATION, 2004, 110 (25) : 3773 - 3780
  • [8] Angiographic Patterns of Restenosis After Sirolimus-Eluting Stent Implantation
    Kitahara, Hideki
    Kobayashi, Yoshio
    Takebayashi, Hideo
    Nakamura, Yoshitake
    Kuroda, Nakabumi
    Miyazaki, Akira
    Haruta, Seiichi
    Komuro, Issei
    CIRCULATION JOURNAL, 2009, 73 (03) : 508 - 511
  • [9] Predictive factors of cardiac events after implantation of sirolimus-eluting stents for treatment of in-stent restenosis
    Le Feuvre, C
    Montalescot, G
    Rosey, G
    Collet, JP
    Beygui, F
    Choussat, R
    Gelft, G
    Monségu, J
    Ohanessian, A
    Spaulding, C
    Drobinski, G
    Metzger, JP
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (02) : 207 - 212
  • [10] Cost-effectiveness of sirolimus-eluting stents for treatment of complex coronary stenoses - Results from the sirolimus-eluting balloon expandable stent in the treatment of patients with de novo native coronary artery lesions (SIRIUS) trial
    Cohen, DJ
    Bakhai, A
    Shi, CX
    Githiora, L
    Lavelle, T
    Berezin, RH
    Leon, MB
    Moses, JW
    Carrozza, JP
    Zidar, JP
    Kuntz, RE
    CIRCULATION, 2004, 110 (05) : 508 - 514