Ultrahigh-resolution CT scan of the temporal bone

被引:43
作者
Yamashita, Koji [1 ]
Hiwatashi, Akio [2 ]
Togao, Osamu [1 ]
Kikuchi, Kazufumi [1 ]
Matsumoto, Nozomu [3 ]
Momosaka, Daichi [1 ]
Nakatake, Hiroshi [1 ]
Sakai, Yuki [4 ]
Honda, Hiroshi [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[2] Kyushu Univ, Grad Sch Med Sci, Dept Mol Imaging & Diag, Fukuoka, Fukuoka, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Otorhinolaryngol, Fukuoka, Fukuoka, Japan
[4] Kyushu Univ Hosp, Div Radiol, Dept Med Technol, Fukuoka, Fukuoka, Japan
关键词
Computed tomography; Temporal bone; Anatomy; COMPUTED-TOMOGRAPHY; STAPEDIUS TENDON; MIDDLE-EAR; ROW CT; ANATOMY; DIAGNOSIS; UTILITY;
D O I
10.1007/s00405-018-5101-6
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectiveUltrahigh-resolution CT (U-HRCT) provides better spatial resolution than conventional multi-detector row CT (ConvCT) and could be expected to identify microstructures with its 0.25-mm collimation, 1792 channels and 160 detector rows, 0.4x0.5mm focus size, and a 1024 matrix. The aim of the study was to evaluate key anatomic structures in temporal bone using U-HRCT comparing it to ConvCT.Materials and methodsA total of 30 patients (14 males and 16 females; age range, 8-82 years; median 49years) underwent both U-HRCT and ConvCT. All CT images were obtained with 0.5mm section thickness and a 512x512 matrix, and field of view of 80mm. Transverse scans were acquired in a plane parallel to the orbitomeatal plane in the helical mode with 120kV. Images of the 30 temporal bones of unaffected side were reviewed by two independent neuroradiologists who rated the visibility of key anatomic structures for both U-HRCT and ConvCT. The ratings between U-HRCT and ConvCT were compared using Wilcoxon matched-pairs signed rank test. The interobserver agreement on the rating of stapedius tendon was evaluated using weighted statistics.ResultsExcellent interobserver agreement was shown for U-HRCT (=0.920), whereas good agreement was obtained for ConvCT (=0.733). According to both observers, stapedius tendon was more clearly visualized using U-HRCT than ConvCT (p<0.0001). All other anatomic structures were well visualized using both CT scanners.ConclusionThe anatomy of temporal bone is more conspicuous on U-HRCT than on ConvCT because of its ultra-high-resolution detector. U-HRCT may provide beneficial information for determining surgical indication or procedures.
引用
收藏
页码:2797 / 2803
页数:7
相关论文
共 23 条
[1]   High-resolution flat-panel volume-CT of temporal bone - Part 1 - Axial preoperative anatomy [J].
Bartling, SH ;
Shukla, V ;
Becker, H ;
Brady, TJ ;
Hayman, A ;
Gupta, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (03) :420-423
[2]   Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses [J].
Bozzato, Alessandro ;
Struffert, Tobias ;
Hertel, Victoria ;
Iro, Heinrich ;
Hornung, Joachim .
EUROPEAN RADIOLOGY, 2010, 20 (03) :566-571
[3]   High-resolution computed tomography of isolated congenital anomalies of the stapes: A pictural review using oblique multiplanar reformation in the "axial stapes" plane [J].
Gentric, Jean-Christophe ;
Rousset, Jean ;
Garetier, Marc ;
Ben Salem, Douraied ;
Meriot, Philippe .
JOURNAL OF NEURORADIOLOGY, 2012, 39 (01) :57-63
[4]   High resolution computed tomography and magnetic resonance imaging in the pre-operative assessment of cochlear implant patients [J].
Gleeson, TG ;
Lacy, PD ;
Bresnihan, M ;
Gaffney, R ;
Brennan, P ;
Viani, L .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2003, 117 (09) :692-695
[5]   Assessing Stapes Piston Position Using Computed Tomography: A Cadaveric Study [J].
Hahn, Yoav ;
Diaz, Rodney ;
Hartman, Jonathan ;
Bobinski, Matthew ;
Brodie, Hilary .
OTOLOGY & NEUROTOLOGY, 2009, 30 (02) :223-230
[6]   METHOD FOR COMBINING OCCURRENCE AND NON-OCCURRENCE INTEROBSERVER AGREEMENT SCORES [J].
HARRIS, FC ;
LAHEY, BB .
JOURNAL OF APPLIED BEHAVIOR ANALYSIS, 1978, 11 (04) :523-527
[7]  
Henrot P, 2005, AM J NEURORADIOL, V26, P2128
[8]   CT of the normal temporal bone:: Comparison of multiand single-detector row CT [J].
Jäger, L ;
Bonell, H ;
Liebl, M ;
Srivastav, S ;
Arbusow, V ;
Hempel, M ;
Reiser, M .
RADIOLOGY, 2005, 235 (01) :133-141
[9]  
Kahn JB, 2000, AM J OTOL, V21, P743
[10]   Vascular anomalies, sutures and small canals of the temporal bone on axial CT [J].
Koesling, S ;
Kunkel, P ;
Schul, T .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) :335-343