Building Environmental Assessment Schemes for Rating of IAQ in Sustainable Buildings

被引:125
作者
Yu, Chuck W. F. [1 ]
Kim, Jeong Tai [2 ]
机构
[1] ISBE, Milton Keynes MK7 8HQ, Bucks, England
[2] Kyung Hee Univ, Dept Architectural Engn, Ctr Sustainable Healthy Bldg CSHeB, Yongin 446701, South Korea
关键词
Green buildings; Indoor environmental quality; Indoor air quality; Sustainable development; Building environmental assessment; Health and wellbeing; INDOOR AIR-QUALITY; THERMAL ENVIRONMENT; DISCOMFORT GLARE; SICK BUILDINGS; HUMAN HEALTH; COMFORT; VENTILATION; PERFORMANCE; ILLUMINANCE; PERCEPTION;
D O I
10.1177/1420326X10397780
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper provides a review of the building environmental schemes for rating of indoor air quality which could have an important impact on health and wellbeing of occupants in sustainable homes and buildings. The majority of the building environmental assessment schemes introduced in different countries of the world are based on the BREEAM and LEED model. BREEAM has a major emphasis on energy efficiency whereas ''Indoor Environmental Quality'' and ''Health and Wellbeing'' are the most central issues for LEED. The criteria included in BREEAM, LEED and HK BEAM rating systems for assessment of indoor air quality (IAQ) are illustrated. There should be an IAQ management plan for any housing or building development, which should include a certification of the IAQ of the living spaces prior to occupancy and that low emitting materials should be used in the new build. There should also be an ongoing maintenance of the ventilation and HVAC system for the building and this should be part of an IAQ management plan for the building operation and maintenance.
引用
收藏
页码:5 / 15
页数:11
相关论文
共 78 条
[1]   The HOPE project: The UK experience [J].
Aizlewood, C. ;
Dimitroulopoulou, C. .
INDOOR AND BUILT ENVIRONMENT, 2006, 15 (05) :393-409
[2]  
ANDERSON J, 2000, 390 BR
[3]  
[Anonymous], Green Building Basic Information
[4]   Associations between indoor CO2 concentrations and sick building syndrome symptoms in US office buildings:: An analysis of the 1994-1996 BASE study data [J].
Apte, MG ;
Fisk, WJ ;
Daisey, JM .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04) :246-257
[5]  
*ASTM INT, 2002, D624598 ASTM INT
[6]  
ATKINSON C, 2009, BR502
[7]   Actions to Reduce the Impact of Construction Products on Indoor Air: Outcomes of the European Project HealthyAir [J].
Bluyssen, Philomena M. ;
de Richemont, Sabine ;
Crump, Derrick ;
Maupetit, Francois ;
Witterseh, Thomas ;
Gajdos, Petr .
INDOOR AND BUILT ENVIRONMENT, 2010, 19 (03) :327-339
[8]   Management of the Indoor Environment: from a Component Related to an Interactive Top-down Approach [J].
Bluyssen, Philomena M. .
INDOOR AND BUILT ENVIRONMENT, 2008, 17 (06) :483-495
[9]  
BONES A, 2010, PERSPECTIVES PUBLIC
[10]   The Impact of Light in Buildings on Human Health [J].
Boyce, Peter R. .
INDOOR AND BUILT ENVIRONMENT, 2010, 19 (01) :8-20