Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis

被引:29
作者
Kandemir, Utku [1 ]
Augat, Peter [2 ,3 ]
Konowalczyk, Stefanie [4 ]
Wipf, Felix [4 ]
von Oldenburg, Geert [5 ]
Schmidt, Ulf [6 ]
机构
[1] Univ Calif San Francisco, Dept Orthoped Surg, San Francisco, CA 94143 USA
[2] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
[3] Berufsgenossenschaftl Unfallklin, Inst Biomech, Murnau, Germany
[4] Stryker, Selzach, Switzerland
[5] Stryker, Kiel, Germany
[6] Krankenhaus Barmherzigen Schwestern Ried, Dept Trauma Orthopaed Surg, Schlossberg 1, A-4910 Ried Im Innkreis, Austria
关键词
implant; material; distal femur; biomechanics; osteosynthesis; ANGLED BLADE PLATE; LCP CONDYLAR PLATE; FEMORAL FRACTURES; OSTEOPOROTIC BONE; INTERNAL-FIXATION; LOCKING PLATES; INTRAMEDULLARY NAIL; EPIDEMIOLOGY; STABILITY; FORCES;
D O I
10.1097/BOT.0000000000000860
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. Methods: An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Results: Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Conclusions: Using the same plate design, the study showed that implant material, screw type, and position of the plate affect the construct stiffness and fatigue life of the fixation construct. With this knowledge, the surgeon can decide the optimal construct based on a given fracture pattern, bone strength, and reduction quality.
引用
收藏
页码:E241 / E246
页数:6
相关论文
共 44 条
[21]   Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation [J].
Lujan, Trevor J. ;
Henderson, Chris E. ;
Madey, Steven M. ;
Fitzpatrick, Dan C. ;
Marsh, J. Lawrence ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (03) :156-162
[22]   The epidemiology of fractures of the distal femur [J].
Martinet, O ;
Cordey, J ;
Harder, Y ;
Maier, A ;
Bühler, M ;
Barraud, GE .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 :62-63
[23]   Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail [J].
Meyer, RW ;
Plaxton, NA ;
Postak, PD ;
Gilmore, A ;
Froimson, MI ;
Greenwald, AS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) :398-404
[24]  
Mueller ME, 1990, COMPREHENSIVE CLASSI, P120
[25]   Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures [J].
Otto, Randall J. ;
Moed, Berton R. ;
Bledsoe, J. Gary .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) :645-652
[26]   Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures A CADAVER-BASED LABORATORY INVESTIGATION [J].
Pekmezci, M. ;
McDonald, E. ;
Buckley, J. ;
Kandemir, U. .
BONE & JOINT JOURNAL, 2014, 96B (01) :114-121
[27]   Evolution of the internal fixation of long bone fractures - The scientific basis of biological internal fixation: Choosing a new balance between stability and biology [J].
Perren, SM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08) :1093-1110
[28]   Risk Factors for Failure of Locked Plate Fixation of Distal Femur Fractures: An Analysis of 335 Cases [J].
Ricci, William M. ;
Streubel, Philipp N. ;
Morshed, Saam ;
Collinge, Cory A. ;
Nork, Sean E. ;
Gardner, Michael J. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (02) :83-89
[29]   Mechanical Construct Characteristics Predisposing to Non-union After Locked Lateral Plating of Distal Femur Fractures [J].
Rodriguez, Edward K. ;
Zurakowski, David ;
Herder, Lindsay ;
Hall, Amber ;
Walley, Kempland C. ;
Weaver, Mike J. ;
Appleton, Paul T. ;
Vrahas, Mark .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (08) :403-408
[30]   Predictive factors of distal femoral fracture nonunion after lateral locked plating: A retrospective multicenter case-control study of 283 fractures [J].
Rodriguez, Edward K. ;
Boulton, Christina ;
Weaver, Michael J. ;
Herder, Lindsay M. ;
Morgan, Jordan H. ;
Chacko, Aron T. ;
Appleton, Paul T. ;
Zurakowski, David ;
Vrahas, Mark S. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03) :554-559