Evaluation of ultrasound-based prostate localization for image-guided radiotherapy

被引:192
作者
Langen, KM
Pouliot, J
Anezinos, C
Aubin, M
Gottschalk, AR
Hsu, IC
Lowther, D
Liu, YM
Shinohara, K
Verhey, LJ
Weinberg, V
Roach, M
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Sch Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Urol, Sch Med, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 03期
关键词
prostate cancer; organ motion; daily prostate localization;
D O I
10.1016/S0360-3016(03)00633-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the use of the ultrasound-based BAT system for daily prostate alignment. Materials and Methods: Prostate alignments using the BAT system were compared with alignments using radiographic images of implanted radiopaque markers. The latter alignments were used as a reference. The difference between the BAT and marker alignments represents the displacements that would remain if the alignments were done using ultrasonography. The inter-user variability of the contour alignment process was assessed. Results: On the basis of the marker alignments, the initial displacement of the prostate in the AP, superoinferior, and lateral direction was -0.9 +/- 3.9, 0.1 +/- 3.9, and 0.2 +/- 3.4 mm respectively. The directed differences between the BAT and marker alignments in the respective directions were 0.2 +/- 3.7, 2.7 +/- 3.9, and 1.6 +/- 3.1 mm. The occurrence of displacements 2:5 mm was reduced by a factor of two in the AP direction after the BAT system was used. Among eight users, the average range of couch shifts due to contour alignment variability was 7, 7, and 5 mm in the antero-posterior (AP), superoinferior, and lateral direction, respectively. Conclusion: In our study, the BAT alignments were systematically different from the marker alignments in the superoinferior, and lateral directions. The remaining random variability of the prostate position after the ultrasound-based alignment was similar to the initial variability. However, the occurrence of displacements 2:5 mm was reduced in the AP direction. The inter-user variation of the contour alignment process was significant. (C) 2003 Elsevier Inc.
引用
收藏
页码:635 / 644
页数:10
相关论文
共 16 条
[1]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[2]   Managing geometric uncertainty in conformal intensity-modulated radiation therapy [J].
Jaffray, DA ;
Yan, D ;
Wong, JW .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :4-19
[3]   A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer [J].
Lattanzi, J ;
McNeeley, S ;
Pinover, W ;
Horwitz, E ;
Das, I ;
Schultheiss, TE ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :719-725
[4]   Daily CT localization for correcting portal errors in the treatment of prostate cancer [J].
Lattanzi, J ;
McNeely, S ;
Hanlon, A ;
Das, I ;
Schultheiss, TE ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05) :1079-1086
[5]   Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer [J].
Lattanzi, J ;
McNeeley, S ;
Hanlon, A ;
Schultheiss, TE ;
Hanks, GE .
UROLOGY, 2000, 55 (01) :73-78
[6]   Impact of differences in ultrasound and computed tomography volumes on treatment planning of permanent prostate implants [J].
Narayana, V ;
Roberson, PL ;
Pu, AT ;
Sandler, H ;
Winfield, RH ;
McLaughlin, PW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05) :1181-1185
[7]   THE VALUE OF NONUNIFORM MARGINS FOR 6-FIELD CONFORMAL IRRADIATION OF LOCALIZED PROSTATE-CANCER [J].
PICKETT, B ;
ROACH, M ;
VERHEY, L ;
HORINE, P ;
MALFATTI, C ;
AKAZAWA, C ;
DEA, D ;
VARAD, B ;
RATHBUN, C ;
PHILLIPS, TL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (01) :211-218
[8]   (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device [J].
Pouliot, J ;
Aubin, M ;
Langen, KM ;
Liu, YM ;
Pickett, B ;
Shinohara, K ;
Roach, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03) :862-866
[9]  
Roach M 3rd, 1997, Radiat Oncol Investig, V5, P187, DOI 10.1002/(SICI)1520-6823(1997)5:4<187::AID-ROI4>3.0.CO
[10]  
2-U