A Cloud-Connected Multi-Lead Electrocardiogram (ECG) Sensor Ring

被引:11
作者
Dong, Quan [1 ]
Downen, R. Scott [1 ]
Li, Baichen [1 ]
Tran, Nam [1 ]
Li, Zhenyu [1 ]
机构
[1] George Washington Univ, Dept Biomed Engn, Washington, DC 20052 USA
关键词
Wearable ECG; 12 lead ECGs; wearable sensors; medical IoT; Bluetooth Low Energy; cloud informatics system; telemedicine; point-of-care; ARTIFICIAL-INTELLIGENCE; UNIVERSAL DEFINITION; SCIENTIFIC STATEMENT; HEART; COUNCIL; NOISE; DELAY;
D O I
10.1109/JSEN.2021.3075992
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability to acquire multi-lead electrocardiograms (ECGs) in a timely manner is critical to patient survival and better clinical outcomes after acute cardiac events, including myocardial infarctions (MI). However, current wearable ECG devices do not provide the traditional 12-lead information needed for clinical MI diagnosis. Here, we report, to our knowledge, the first finger-ring-shaped ECG sensor that can provide asynchronously derived 12-lead ECGs by sequentially placing the ring on eight defined locations on the body. We demonstrate that the sensor performance is comparable to that of a clinical 12-lead ECG machine in a human subject study. The ring ECG sensor has an input-referred electronics noise floor of less than 10uV (peak-to-peak) with a 480X gain and a bandwidth of 0.16 similar to 156 Hz. The battery lasts similar to 5 days under normal usage. The ring sensor can also wirelessly upload data to a cloud-based medical IoT informatics system via a smartphone gateway. Combined with advancements in cloud computing, telemedicine, and artificial intelligence, this on-demand IoT ECG sensor can potentially help high-risk cardiac patients reduce prehospital delays and seek timely life-saving interventions.
引用
收藏
页码:16340 / 16349
页数:10
相关论文
共 38 条
  • [1] [Anonymous], 2011, WHO I Global atlas on cardiovascular disease prevention and control
  • [2] Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram
    Attia, Zachi I.
    Kapa, Suraj
    Lopez-Jimenez, Francisco
    McKie, Paul M.
    Ladewig, Dorothy J.
    Satam, Gaurav
    Pellikka, Patricia A.
    Enriquez-Sarano, Maurice
    Noseworthy, Peter A.
    Munger, Thomas M.
    Asirvatham, Samuel J.
    Scott, Christopher G.
    Carter, Rickey E.
    Friedman, Paul A.
    [J]. NATURE MEDICINE, 2019, 25 (01) : 70 - +
  • [3] Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring
    Barrett, Paddy M.
    Komatireddy, Ravi
    Haaser, Sharon
    Topol, Sarah
    Sheard, Judith
    Encinas, Jackie
    Fought, Angela J.
    Topol, Eric J.
    [J]. AMERICAN JOURNAL OF MEDICINE, 2014, 127 (01) : 95.e11 - 95.e17
  • [4] Benjamin E. J., 2018, CIRCULATION, V137, P67, DOI [DOI 10.1161/CIR.0000000000000573, 10.1161/CIR.0000000000000558]
  • [5] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [6] What Happened in my Home?: An End-User Development Approach for Smart Home Data Visualization
    Castelli, Nico
    Ogonowski, Corinna
    Jakobi, Timo
    Stein, Martin
    Stevens, Gunnar
    Wulf, Volker
    [J]. PROCEEDINGS OF THE 2017 ACM SIGCHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI'17), 2017, : 853 - 866
  • [7] Time-to-treatment significantly affects the extent of ST-segment resolution and myocardial blush in patients with acute myocardial infarction treated by primary angioplasty
    De Luca, G
    van't Hof, AWJ
    de Boer, MJ
    Ottervanger, JP
    Hoorntje, JCA
    Gosselink, ATM
    Dambrink, JHE
    Zijlstra, F
    Suryapranata, H
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 (12) : 1009 - 1013
  • [8] Dong Q, 2020, IEEE SENS J, V20, P15143, DOI [10.1109/JSEN.2020.3009911, 10.1109/jsen.2020.3009911]
  • [9] DERIVING THE 12-LEAD ELECTROCARDIOGRAM FROM 4 (EASI) ELECTRODES
    DOWER, GE
    YAKUSH, A
    NAZZAL, SB
    JUTZY, RV
    RUIZ, CE
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 : S182 - S187
  • [10] Fielding R., 2000, ARCHITECTURAL STYLES, P76