Influence of Diameter and Length of Implant on Early Dental Implant Failure

被引:115
作者
Olate, Sergio [2 ]
Negreiros Lyrio, Mariana Camilo
de Moraes, Marcio [3 ]
Mazzonetto, Renato [3 ]
Fernandes Moreira, Roger William [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral & Maxillofacial Surg, Piracicaba, SP, Brazil
[2] Univ La Frontera, Sch Med, Temuco, Chile
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Maxillofacial Surg, Piracicaba, SP, Brazil
关键词
MACHINED-SURFACE IMPLANTS; PROSPECTIVE MULTICENTER; CLINICAL-EVALUATION; TITANIUM IMPLANTS; PART I; BONE; RESTORATIONS; SURVIVAL; MAXILLA; DESIGN;
D O I
10.1016/j.joms.2009.10.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To relate diameter and length of implants with early implant failure. Patients and Methods: Implants with a cylindrical design and surface treatment by removal of titanium via acidification from 3 different manufacturers were used in this study. Two surgical procedures for submerged implants were evaluated the placement of the implants (first surgical phase) and the procedure for reopening (second surgical phase) before the installation of the prosthetic system. The length of the implants was classified as short (6-9 mm), medium (10-12 mm), or long (13-18 mm), and the diameter was classified as narrow, regular, or wide. The statistics were computed with SAS statistical software (SAS Institute, Cary, NC). Step-wise and chi(2) analyses were used, in addition to univariate and multivariate logistic regression. Results: In this retrospective study, 1,649 implants (807 maxillary and 821 mandibular) were placed in 650 patients (mean age, 42.7 years) in different areas: anterior maxilla (458), posterior maxilla (349), anterior mandible (270), and posterior mandible (551). The early survival rate for all 1,649 implants was 96.2%. Regarding diameter, the largest loss was observed in narrow implants (5.1%), followed by regular (3.8%) and wide (2.7%) implants. Regarding length, the largest loss was observed in short implants (9.9%), followed by long (3.4%) and medium (3.0%) implants. Early loss occurred in 50 implants, 31 (4.3%) of which were installed in anterior areas and 19 (2.8%) in posterior areas. According to step-wise analyses and the chi(2) test, short implant (P = .0018) and anterior installation of implant (P = .0013) showed associations with early loss. Conclusion: A significant relationship of early implant loss was observed with short implants. No relationships between early loss of implants and the osseous quality or diameter of implants were observed. These findings may be attributed to the operator's experience with different implant designs, learning curves, or changes in technique and indications for the use of short implants from 1996 to 2004. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:414-419, 2010
引用
收藏
页码:414 / 419
页数:6
相关论文
共 50 条
  • [21] Impact of Different Surgeons on Dental Implant Failure
    Chrcanovic, Bruno Ramos
    Kisch, Jeno
    Albrektsson, Tomas
    Wennerberg, Ann
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (05) : 445 - 454
  • [22] Minimization of dental implant diameter and length according to bone quality determined by finite element analysis and optimized calculation
    Ueda, Nana
    Takayama, Yoshiyuki
    Yokoyama, Atsuro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (03) : 324 - 332
  • [23] Survival of dental implants at sites after implant failure: A systematic review
    Oh, Se-Lim
    Shiau, Harlan J.
    Reynolds, Mark A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) : 54 - 60
  • [24] Dental Implant Design and Optimal Treatment Outcomes
    Deporter, Douglas
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2009, 29 (06) : 625 - 633
  • [25] The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
    Robau-Porrua, Amanda
    Perez-Rodriguez, Yoan
    Soris-Rodriguez, Laura M.
    Perez-Acosta, Osmel
    Gonzalez, Jesus E.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 541 - 558
  • [26] Application of a narrow-diameter implant in a limited space
    Tsai, Chia-Yun
    Tsai, Ching-Fang
    Tseng, Yu-Chuan
    Kung, Jung-Chang
    Wu, Yi-Min
    JOURNAL OF DENTAL SCIENCES, 2010, 5 (02) : 114 - 120
  • [27] Cluster behavior in dental implant failure - A scoping review
    Bidra, Avinash S.
    Volp Junior, Luiz Carlos
    Iverson, Marissa
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 9 - 14
  • [28] The relationship between dental implant papilla and dental implant mucosa around single-tooth implant in the esthetic area: A retrospective study
    Garabetyan, Julia
    Malet, Jacques
    Kerner, Stephane
    Detzen, Laurent
    Carra, Maria Clotilde
    Bouchard, Philippe
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) : 1229 - 1237
  • [29] Single implant retained overdentures: Evaluation of effect of implant length and diameter on stress distribution by finite element analysis
    Eraslan, Ravza
    Yagci, Filiz
    Esim, Emir
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (04): : 348 - 357
  • [30] Effects of implant length and 3D bone-to-implant contact on initial stabilities of dental implant: a microcomputed tomography study
    Hsu, Jui-Ting
    Wu, Aaron Yu-Jen
    Fuh, Lih-Jyh
    Huang, Heng-Li
    BMC ORAL HEALTH, 2017, 17