Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner

被引:116
作者
Devotta, S [1 ]
Padalkar, AS
Sane, NK
机构
[1] Natl Environm Engn Res Inst, Nagpur 44020, Maharashtra, India
[2] Natl Chem Lab, Proc Dev Div, Pune 411008, Maharashtra, India
[3] Walchand Coll Engn, Dept Mech Engn, Sangli 416415, India
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2005年 / 28卷 / 04期
关键词
air conditioner; window; experiment; propane; R-22; performance; COP; simulation; evaporator;
D O I
10.1016/j.ijrefrig.2004.09.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
As per the Montreal Protocol, CFCs and HCFCs are being phased out. HCFC-22 is used in window air conditioners. This paper presents the experimental performance study of a window air conditioner with propane (HC-290), a natural refrigerant, as a drop-in substitute to HCFC-22. Experimental results showed that HC-290 had 6.6% lower cooling capacity for the lower operating conditions and 9.7% lower for the higher operating conditions with respect to HCFC-22. The coefficient of performance for HC290 was 7.9% higher for the lower operating conditions and 2.8% higher for the higher operating conditions. The energy consumption of the unit with HC-290 was lower in the range 12.4-13.5% than HCFC-22. The discharge pressures for HC-290 were lower in the range 13.7-18.2% than HCFC-22. For HC-290, the pressure drop was lower than HCFC-22 in both heat exchangers. This paper also presents simulation results for the heat exchangers of an HCFC-22 window air conditioner with HC-290 as a drop-in substitute. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by NIST [National Institute of Standards and Technology. EVAP-COND: simulation models for finned-tube heat exchangers, Maryland, USA (2003). http://www2.bfrl.nist.gov/software/evap-cond/ [18]]. The simulated evaporator capacities are within +/- 4% of the experimentally measured cooling capacities for both refrigerants. Simulation results for HC-290 and HCFC-22 are compared. The exit temperatures of HC-290 are lower by 0.3-1.2 degrees C in the condenser and are higher by 2.1-2.4 degrees C in the evaporator than HCFC-22. Evaporating pressures of HC-290 are lower by 2.1-3.3% as compared to HCFC-22. The pressure drops of HC-290 are lower in both the evaporator and the condenser as compared to HCFC-22. The outlet temperatures of air for HCFC-22 and HC-290 in both heat exchangers are nearly the same. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:594 / 604
页数:11
相关论文
共 22 条
[1]  
*AIR COND REFR I, 1997, SOFT OP SYST TESTS C
[2]  
Bureau of Indian Standards, 1992, IS1391 BUR IND STAND
[3]  
Calm J.M., 2001, Eng. Syst., V18, P74
[4]  
Colbourne D, 2002, P 16 INT COMPR ENG C
[5]   Alternatives to HCFC-22 for air conditioners [J].
Devotta, S ;
Waghmare, AV ;
Sawant, NN ;
Domkundwar, BM .
APPLIED THERMAL ENGINEERING, 2001, 21 (06) :703-715
[6]  
DEVOTTA S, 2003, 21 INT C REFR WASH D
[7]  
Devotta S, 2000, P 4 IIR GUST LOR C N, P17
[8]   Hydrocarbons as refrigerants - an overview [J].
Granryd, E .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (01) :15-24
[9]  
Grob DP, 1998, STATUS SAFETY REQUIR
[10]  
Hammand M., 2000, P 4 IIR GUST LOR C N, P167