The "Subtle" connection between development of cardiac implantable electrical device infection and survival after complete system removal: An observational prospective multicenter study

被引:32
作者
Diemberger, Igor [1 ]
Migliore, Federico [2 ]
Biffi, Mauro [1 ]
Cipriani, Alberto [2 ]
Bertaglia, Emanuele [2 ]
Lorenzetti, Stefano [1 ]
Massaro, Giulia [1 ]
Tanzarella, Gaia [1 ]
Boriani, Giuseppe [1 ,3 ]
机构
[1] Univ Bologna, Policlin S Orsola Malpighi, Dept Expt Diagnost & Specialty Med, Inst Cardiol, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[3] Univ Modena & Reggio Emilia, Policlin Modena, Dept Diagnost Clin & Publ Hlth Med, Cardiol Div, Modena, Italy
关键词
Pacemaker; Defibrillator; Lead extraction; Endocarditis; Infection; Vegetation; TRANSVENOUS LEAD EXTRACTION; ELECTRONIC DEVICES; MANAGEMENT; PREVENTION; MORTALITY; ENVELOPE;
D O I
10.1016/j.ijcard.2017.07.061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite the improvements in transvenous lead extraction (TLE), patients with cardiac implantable device related infection (CIEDI) have a poor prognosis at long term. We explored the possible role of factors associated with development of CIEDI as predictors of post-TLE survival. Methods: We performed a multi-center prospective observational study in a population of consecutive patients referred for TLE for CIEDI. We adopted a previously developed 10-point scale for CIEDI risk stratification and assessed its performance in predicting post-TLE survival. Results: We enrolled 169 consecutive patients with CIEDI (systemic infection in 48.5% and vegetations in 24.5%). A Shariff score (=>=) 3 was present in 102/169 (60.4%) of the enrolled patients. Complete radiological success of TLE was obtained in 163 patients. Twenty-seven patients (15.9%) died after a mean follow-up of 20.8 +/- 12.0 months. Two factors were independently associated with post-TLE death: a Shariff score >= 3 (HR 10.833, 95% CI 2.544-46.129; p = 0.001) and the presence of vegetations at transesophageal echocardiography (HR 3.324, 95% CI 1.530-7.221; p = 0.002). Conclusions: Risk factors for development of CIEDI are also predictive of post TLE mortality, together with the presence of vegetations. Improvement of our preventive strategies for CIEDI is crucial for enhancing the outcomes of CIED patients overall. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 20 条
[11]   From lead management to implanted patient management: indications to lead extraction in pacemaker and cardioverter-defibrillator systems [J].
Diemberger, Igor ;
Biffi, Mauro ;
Martignani, Cristian ;
Boriani, Giuseppe .
EXPERT REVIEW OF MEDICAL DEVICES, 2011, 8 (02) :235-255
[12]  
Habib G, 2015, EUR HEART J, V36, P3075, DOI [10.1093/eurheartj/ehv319, 10.5603/KP.2015.0227]
[13]   Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis [J].
Li, JS ;
Sexton, DJ ;
Mick, N ;
Nettles, R ;
Fowler, VG ;
Ryan, T ;
Bashore, T ;
Corey, GR .
CLINICAL INFECTIOUS DISEASES, 2000, 30 (04) :633-638
[14]  
Mazzone P, 2017, EUROPACE
[15]   Lead-related infective endocarditis: Factors influencing early and long-term survival in patients undergoing transvenous lead extraction [J].
Polewczyk, Anna ;
Jachec, Wojciech ;
Tomaszewski, Andrzej ;
Brzozowski, Wojciech ;
Czajkowski, Marek ;
Opolski, Grzegorz ;
Grabowski, Marcin ;
Janion, Marianna ;
Kutarski, Andrzej .
HEART RHYTHM, 2017, 14 (01) :43-49
[16]   Health and Economic Outcomes Associated with Use of an Antimicrobial Envelope as a Standard of Care for Cardiac Implantable Electronic Device Implantation [J].
Shariff, Nasir ;
Eby, Elizabeth ;
Adelstein, Evan ;
Jain, Sandeep ;
Shalaby, Alaa ;
Saba, Samir ;
Wang, Norman C. ;
Schwartzman, David .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (07) :783-789
[17]   A statement on ethical standards in publishing scientific articles in the International Journal of Cardiology family of journals [J].
Shewan, Louise G. ;
Rosano, Giuseppe ;
Henein, Michael ;
Coats, Andrew J. S. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 170 (03) :253-254
[18]   Mortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections [J].
Sohail, Muhammad R. ;
Henrikson, Charles A. ;
Braid-Forbes, Mary Jo ;
Forbes, Kevin F. ;
Lerner, Daniel J. .
ARCHIVES OF INTERNAL MEDICINE, 2011, 171 (20) :1821-1828
[19]   Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial (WRAP-IT) [J].
Tarakji, Khaldoun G. ;
Mittal, Suneet ;
Kennergren, Charles ;
Corey, Ralph ;
Poole, Jeanne ;
Stromberg, Kurt ;
Lexcen, Daniel R. ;
Wilkoff, Bruce L. .
AMERICAN HEART JOURNAL, 2016, 180 :12-21
[20]   Risk factors for 1-year mortality among patients with cardiac implantable electronic device infection undergoing transvenous lead extraction: the impact of the infection type and the presence of vegetation on survival [J].
Tarakji, Khaldoun G. ;
Wazni, Oussama M. ;
Harb, Serge ;
Hsu, Amy ;
Saliba, Walid ;
Wilkoff, Bruce L. .
EUROPACE, 2014, 16 (10) :1490-1495