The "Subtle" connection between development of cardiac implantable electrical device infection and survival after complete system removal: An observational prospective multicenter study

被引:32
作者
Diemberger, Igor [1 ]
Migliore, Federico [2 ]
Biffi, Mauro [1 ]
Cipriani, Alberto [2 ]
Bertaglia, Emanuele [2 ]
Lorenzetti, Stefano [1 ]
Massaro, Giulia [1 ]
Tanzarella, Gaia [1 ]
Boriani, Giuseppe [1 ,3 ]
机构
[1] Univ Bologna, Policlin S Orsola Malpighi, Dept Expt Diagnost & Specialty Med, Inst Cardiol, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Padua, Italy
[3] Univ Modena & Reggio Emilia, Policlin Modena, Dept Diagnost Clin & Publ Hlth Med, Cardiol Div, Modena, Italy
关键词
Pacemaker; Defibrillator; Lead extraction; Endocarditis; Infection; Vegetation; TRANSVENOUS LEAD EXTRACTION; ELECTRONIC DEVICES; MANAGEMENT; PREVENTION; MORTALITY; ENVELOPE;
D O I
10.1016/j.ijcard.2017.07.061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite the improvements in transvenous lead extraction (TLE), patients with cardiac implantable device related infection (CIEDI) have a poor prognosis at long term. We explored the possible role of factors associated with development of CIEDI as predictors of post-TLE survival. Methods: We performed a multi-center prospective observational study in a population of consecutive patients referred for TLE for CIEDI. We adopted a previously developed 10-point scale for CIEDI risk stratification and assessed its performance in predicting post-TLE survival. Results: We enrolled 169 consecutive patients with CIEDI (systemic infection in 48.5% and vegetations in 24.5%). A Shariff score (=>=) 3 was present in 102/169 (60.4%) of the enrolled patients. Complete radiological success of TLE was obtained in 163 patients. Twenty-seven patients (15.9%) died after a mean follow-up of 20.8 +/- 12.0 months. Two factors were independently associated with post-TLE death: a Shariff score >= 3 (HR 10.833, 95% CI 2.544-46.129; p = 0.001) and the presence of vegetations at transesophageal echocardiography (HR 3.324, 95% CI 1.530-7.221; p = 0.002). Conclusions: Risk factors for development of CIEDI are also predictive of post TLE mortality, together with the presence of vegetations. Improvement of our preventive strategies for CIEDI is crucial for enhancing the outcomes of CIED patients overall. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 20 条
[1]   The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes [J].
Bongiorni, Maria Grazia ;
Kennergren, Charles ;
Butter, Christian ;
Deharo, Jean Claude ;
Kutarski, Andrzej ;
Rinaldi, Christopher A. ;
Romano, Simone L. ;
Maggioni, Aldo P. ;
Andarala, Maryna ;
Auricchio, Angelo ;
Kuck, Karl-Heinz ;
Blomstrom-Lundqvist, Carina .
EUROPEAN HEART JOURNAL, 2017, 38 (40) :2995-3005
[2]   Where is the future of cardiac lead extraction heading? [J].
Bongiorni, Maria Grazia ;
Di Cori, Andrea ;
Segreti, Luca ;
Zucchelli, Giulio ;
Viani, Stefano ;
Paperini, Luca ;
Menichetti, Francesca ;
Coluccia, Giovanni ;
Soldati, Ezio .
EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2016, 14 (10) :1197-1203
[3]   ELECTRa (European Lead Extraction ConTRolled) Registry-Shedding light on transvenous lead extraction real-world practice in Europe [J].
Bongiorni M.G. ;
Romano S.L. ;
Kennergren C. ;
Butter C. ;
Deharo J.C. ;
Kutarsky A. ;
Rinaldi C.A. ;
Maggioni A.P. ;
Blomström-Lundqvist C. ;
Auricchio A. .
Herzschrittmachertherapie + Elektrophysiologie, 2013, 24 (3) :171-175
[4]   Subcutaneous implantable cardioverter defibrillators in children, young adults and patients with congenital heart disease [J].
Bordachar, Pierre ;
Marquie, Christelle ;
Pospiech, Thomas ;
Pasquie, Jean-Luc ;
Jalal, Zakaria ;
Haissaguerre, Michel ;
Thambo, Jean-Benoit .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 203 :251-258
[5]   Surgical management of infected cardiac implantable electronic devices [J].
Chaudhry, Umar A. R. ;
Harling, Leanne ;
Ashrafian, Hutan ;
Athanasiou, Christina ;
Tsipas, Pantelis ;
Kokotsakis, John ;
Athanasiou, Thanos .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 203 :714-721
[6]   Transcatheter leadless cardiac pacing The new alternative solution [J].
Da Costa, Antoine ;
Axiotis, Amandine ;
Romeyer-Bouchard, Cecile ;
Abdellaoui, Loucif ;
Afif, Zahi ;
Guichard, Jean Baptiste ;
Gerbay, Antoine ;
Isaaz, Karl .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 227 :122-126
[7]   Prevention of infections in cardiovascular implantable electronic devices beyond the antibiotic agent [J].
De Maria, Elia ;
Diemberger, Igor ;
Vassallo, Pier L. ;
Pastore, Monica ;
Giannotti, Federica ;
Ronconi, Cinzia ;
Romandini, Andrea ;
Biffi, Mauro ;
Martignani, Cristian ;
Ziacchi, Matteo ;
Bonfatti, Federica ;
Tumietto, Fabio ;
Viale, Pierluigi ;
Boriani, Giuseppe .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (07) :554-564
[8]   Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper [J].
Deharo, J. C. ;
Bongiorni, M. G. ;
Rozkovec, A. ;
Bracke, F. ;
Defaye, P. ;
Fernandez-Lozano, I. ;
Golzio, P. G. ;
Hansky, B. ;
Kennergren, C. ;
Manolis, A. S. ;
Mitkowski, P. ;
Platou, E. S. ;
Love, C. ;
Wilkoff, B. .
EUROPACE, 2012, 14 (01) :124-134
[9]   Long-term outcomes following infection of cardiac implantable electronic devices: a prospective matched cohort study [J].
Deharo, Jean-Claude ;
Quatre, Amandine ;
Mancini, Julien ;
Khairy, Paul ;
Le Dolley, Yvan ;
Casalta, Jean-Paul ;
Peyrouse, Eric ;
Prevot, Sebastien ;
Thuny, Franck ;
Collart, Frederic ;
Raoult, Didier ;
Habib, Gilbert ;
Franceschi, Frederic .
HEART, 2012, 98 (09) :724-731
[10]   From lead management to implanted patient management: systematic review and meta-analysis of the last 15 years of experience in lead extraction [J].
Diemberger, Igor ;
Mazzotti, Andrea ;
Biffi, Mauro ;
Massaro, Giulia ;
Martignani, Cristian ;
Ziacchi, Matteo ;
Reggiani, Maria Letizia Bacchi ;
Battistini, Paola ;
Boriani, Giuseppe .
EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (04) :551-573