Quantification of Minimum Detectable Difference in Radiomics Features Across Lesions and CT Imaging Conditions

被引:4
作者
Hoye, Jocelyn [1 ]
Solomon, Justin B. [2 ]
Sauer, Thomas J. [1 ]
Samei, Ehsan [3 ,4 ,5 ,6 ]
机构
[1] Duke Univ, Med Phys Grad Program, Carl E Ravin Adv Imaging Labs, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[2] Carl E Ravin Adv Imaging Labs, Clin Imaging Phys Grp, Med Phys Grad Program, Durham, NC USA
[3] Carl E Ravin Adv Imaging Labs, Clin Imaging Phys Grp, Med Phys Grad Program, Dept Radiol, Durham, NC USA
[4] Carl E Ravin Adv Imaging Labs, Clin Imaging Phys Grp, Med Phys Grad Program, Dept Phys, Durham, NC USA
[5] Carl E Ravin Adv Imaging Labs, Clin Imaging Phys Grp, Med Phys Grad Program, Dept Biomed Engn, Durham, NC USA
[6] Carl E Ravin Adv Imaging Labs, Clin Imaging Phys Grp, Med Phys Grad Program, Dept Elect & Comp, Durham, NC USA
关键词
Radiomics; CT-based Quantification; Morphology; Lung Nodules; Detectable Change; LUNG; VOLUME;
D O I
10.1016/j.acra.2020.07.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The 3-fold purpose of this study was to (1) develop a method to relate measured differences in radiomics features in different computed tomography (CT) scans to one another and to true feature differences; (2) quantify minimum detectable change in radiomics features based on measured radiomics features from pairs of synthesized CT images acquired under variable CT scan settings, and (3) ascertain and inform the recommendations of the Quantitative Imaging Biomarkers Alliance (QIBA) for nodule volumetry. Materials and Methods: Images of anthropomorphic lung nodule models were simulated using resolution and noise properties for 297 unique imaging conditions. Nineteen morphology features were calculated from both the segmentation masks derived from the imaged nodules and from ground truth nodules. Analysis was performed to calculate minimum detectable difference of radiomics features as a function of imaging protocols in comparison to QIBA guidelines. Results: The minimum detectable differences ranged from 1% to 175% depending on the specific feature and set of imaging protocols. The results showed that QIBA protocol recommendations result in improved minimum detectable difference as compared to the range of possible protocols. The results showed that the minimum detectable differences may be improved from QIBA's current recommendation by further restricting the slice thickness requirement to be between 0.5 mm and 1 mm. Conclusion: Minimum detectable differences of radiomics features were quantified for lung nodules across a wide range of possible protocols. The results can be used prospectively to inform decision-making about imaging protocols to provide superior quantification of radiomics features.
引用
收藏
页码:1570 / 1581
页数:12
相关论文
共 23 条
[1]  
[Anonymous], 2018, CT TUM VOL CHANG PRO
[2]   Test-Retest Reproducibility Analysis of Lung CT Image Features [J].
Balagurunathan, Yoganand ;
Kumar, Virendra ;
Gu, Yuhua ;
Kim, Jongphil ;
Wang, Hua ;
Liu, Ying ;
Goldgof, Dmitry B. ;
Hall, Lawrence O. ;
Korn, Rene ;
Zhao, Binsheng ;
Schwartz, Lawrence H. ;
Basu, Satrajit ;
Eschrich, Steven ;
Gatenby, Robert A. ;
Gillies, Robert J. .
JOURNAL OF DIGITAL IMAGING, 2014, 27 (06) :805-823
[3]   Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR) [J].
Chen, Baiyu ;
Barnhart, Huiman ;
Richard, Samuel ;
Robins, Marthony ;
Colsher, James ;
Samei, Ehsan .
MEDICAL PHYSICS, 2013, 40 (11)
[4]   Quantitative CT: technique dependence of volume estimation on pulmonary nodules [J].
Chen, Baiyu ;
Barnhart, Huiman ;
Richard, Samuel ;
Colsher, James ;
Amurao, Maxwell ;
Samei, Ehsan .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1335-1348
[5]   A computational model to generate simulated three-dimensional breast masses [J].
de Sisternes, Luis ;
Brankov, Jovan G. ;
Zysk, Adam M. ;
Schmidt, Robert A. ;
Nishikawa, Robert M. ;
Wernick, Miles N. .
MEDICAL PHYSICS, 2015, 42 (02) :1098-1118
[6]   How accurate and precise are CT based measurements of iodine concentration? A comparison of the minimum detectable concentration difference among single source and dual source dual energy CT in a phantom study [J].
Euler, Andre ;
Solomon, Justin ;
Mazurowski, Maciej A. ;
Samei, Ehsan ;
Nelson, Rendon C. .
EUROPEAN RADIOLOGY, 2019, 29 (04) :2069-2078
[7]   Delta-radiomics features for the prediction of patient outcomes in non-small cell lung cancer [J].
Fave, Xenia ;
Zhang, Lifei ;
Yang, Jinzhong ;
Mackin, Dennis ;
Balter, Peter ;
Gomez, Daniel ;
Followill, David ;
Jones, Aaron Kyle ;
Stingo, Francesco ;
Liao, Zhongxing ;
Mohan, Radhe ;
Court, Laurence .
SCIENTIFIC REPORTS, 2017, 7
[8]   Minimum Detectable Change in Lung Nodule Volume in a Phantom CT Study [J].
Gavrielides, Marios A. ;
Li, Qin ;
Zeng, Rongping ;
Myers, Kyle J. ;
Sahiner, Berkman ;
Petrick, Nicholas .
ACADEMIC RADIOLOGY, 2013, 20 (11) :1364-1370
[9]   Comprehensive Investigation on Controlling for CT Imaging Variabilities in Radiomics Studies [J].
Ger, Rachel B. ;
Zhou, Shouhao ;
Chi, Pai-Chun Melinda ;
Lee, Hannah J. ;
Layman, Rick R. ;
Jones, A. Kyle ;
Goff, David L. ;
Fuller, Clifton D. ;
Howell, Rebecca M. ;
Li, Heng ;
Stafford, Jason ;
Court, Laurence E. ;
Mackin, Dennis S. .
SCIENTIFIC REPORTS, 2018, 8
[10]   Quantifying Truth-based change in Radiomics Features between CT Imaging Conditions [J].
Hoye, Jocelyn ;
Solomon, Justin B. ;
Samei, Ehsan .
MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948