Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: Feasibility and implications

被引:55
作者
Sodickson, DK
Hardy, CJ
Zhu, YD
Giaquinto, RO
Gross, P
Kenwood, G
Niendorf, T
Lejay, H
McKenzie, CA
Ohliger, MA
Grant, AK
Rofsky, NM
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Med, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02215 USA
[4] Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[5] Gen Elect Global Res Ctr, Niskayuna, NY USA
[6] Gen Elect Healthcare Technol, Waukesha, WI USA
关键词
rapid MRI; parallel MRI; volumetric imaging;
D O I
10.1016/j.acra.2005.01.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. Materials and Methods. Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. Results. As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. Conclusion. The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT. (c) AUR, 2005.
引用
收藏
页码:626 / 635
页数:10
相关论文
共 32 条
  • [21] 2-S
  • [22] FAST IMAGING USING SUBENCODING DATA SETS FROM MULTIPLE DETECTORS
    RA, JB
    RIM, CY
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 142 - 145
  • [23] Sodickson DK, 1999, MAGN RESON MED, V41, P1009, DOI 10.1002/(SICI)1522-2594(199905)41:5<1009::AID-MRM21>3.0.CO
  • [24] 2-4
  • [25] Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    Sodickson, DK
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) : 591 - 603
  • [26] A generalized approach to parallel magnetic resonance imaging
    Sodickson, DK
    McKenzie, CA
    [J]. MEDICAL PHYSICS, 2001, 28 (08) : 1629 - 1643
  • [27] SODICKSON DK, 2003, 11 SCI M INT SOC MAG, P469
  • [28] Hyperpolarized 13C MR angiography using TrueFISP
    Svensson, J
    Månsson, S
    Johansson, E
    Petersson, JS
    Olsson, LE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 256 - 262
  • [29] WANG JM, 1995, IEEE T BIO-MED ENG, V42, P908
  • [30] 2D SENSE for faster 3D MRI
    Weiger, M
    Pruessmann, KP
    Boesiger, P
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 14 (01): : 10 - 19