An experimental study on time-based start defrosting control strategy optimization for an air source heat pump unit with frost evenly distributed and melted frost locally drained

被引:45
作者
Song, Mengjie [1 ,2 ]
Fan, Cheng [3 ]
Mao, Ning [4 ]
Xu, Yingjie [5 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Dept Human & Engineered Environm Studies, Tokyo, Japan
[2] Tianjin Univ, Minist Educ China, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300072, Peoples R China
[3] Shenzhen Univ, Dept Construct Management & Real Estate, Shenzhen, Peoples R China
[4] China Univ Petr East China, Coll Pipeline & Civil Engn, Dept Gas Engn, Qingdao, Peoples R China
[5] Zhejiang Univ Technol, Inst Proc Equipment & Control Engn, Hangzhou 310014, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Air source heat pump; Defrosting control strategy; Frost distribution; Melted frost; Defrosting efficiency; 3-CIRCUIT OUTDOOR COIL; EVENNESS VALUES; PERFORMANCE; SYSTEM; REFRIGERANT; ACCUMULATION; EVAPORATOR; EXCHANGER;
D O I
10.1016/j.enbuild.2018.08.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Defrosting operation of an air source heat pump unit is always started with a pre-set time, corresponding to a fixed mass of frost accumulation. The exact defrosting initiation time is hard to be quantitatively given due to dynamic and uneven frosting conditions, and thus resulting in series of mal-defrosting phenomena. For an air source heat pump unit with a multi-circuit outdoor coil, when the melted frost locally drained during defrosting was considered, the optimization of start defrosting control strategy becomes more complicated. Here, this fundamental problem was experimentally investigated, with frost nearly evenly distributed on the surface of the outdoor coil at the start of defrosting. Defrosting performance of the experimental air source heat pump unit at different frost accumulations with the melted frost local drainage were then comparatively analyzed. These measured and calculated physical parameters include the temperature of tube surface and melted frost, compressor suction and discharge pressures and their difference, thermal energy taken from indoor air and electricity inputs on compressor and fans during defrosting, etc. Results showed that, the defrosting efficiency reached its peak at 51.80% when frost accumulation was at 933 g. Thus, the time-based start defrosting control strategy was demonstrated to be optimized with this method. Contributions of this study could be used for adjusting the control strategy of air source heat pump units, which are also benefit for energy saving in their industry and residential applications. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 37
页数:12
相关论文
共 32 条
[1]   Two-stage air-source heat pump for residential heating and cooling applications in northern US climates [J].
Bertsch, Stefan S. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1282-1292
[2]   ICE DETECTION IN HEAT PUMPS AND COOLERS [J].
BUICK, TR ;
MCMULLAN, JT ;
MORGAN, R ;
MURRAY, RB .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1978, 2 (01) :85-98
[3]   First-principles modeling of frost accumulation on fan-supplied tube-fin evaporators [J].
da Silva, Diogo L. ;
Hermes, Christian J. L. ;
Melo, Claudio .
APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) :2616-2621
[4]   Experimental study of frost accumulation on fan-supplied tube-fin evaporators [J].
da Silva, Diogo L. ;
Hermes, Christian J. L. ;
Melo, Claudio .
APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) :1013-1020
[5]  
Hao Y. L., 2002, P 2002 ASME INT MECH
[6]   Frost temperature relations for defrosting sensing system [J].
Iragorry, J ;
Tao, YX .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2005, 127 (03) :344-351
[7]   Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger [J].
Jhee, S ;
Lee, KS ;
Kim, WS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (08) :1047-1053
[8]   A novel defrosting control method based on the degree of refrigerant superheat for air source heat pumps [J].
Jiang, Yiqiang ;
Dong, Jiankai ;
Qu, Minglu ;
Deng, Shiming ;
Yao, Yang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08) :2278-2288
[9]   Determination method of defrosting start-time based on temperature measurements [J].
Kim, Min-Hwan ;
Lee, Kwan-Soo .
APPLIED ENERGY, 2015, 146 :263-269
[10]   A study on the performance enhancement of heat pump using electric heater under the frosting condition: Heat pump under frosting condition [J].
Kwak, Kyungmin ;
Bai, Cheolho .
APPLIED THERMAL ENGINEERING, 2010, 30 (6-7) :539-543