Confidence limit variation for a single IMRT system following the TG119 protocol

被引:13
作者
Gordon, J. D. [1 ]
Krafft, S. P. [1 ]
Jang, S. [1 ]
Smith-Raymond, L. [1 ]
Stevie, M. Y. [1 ]
Hamilton, R. J. [1 ]
机构
[1] Univ Arizona, Dept Radiat Oncol, Tucson, AZ 85724 USA
关键词
IMRT; commissioning; quality assurance; DOCUMENT;
D O I
10.1118/1.3555298
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the robustness of TG119-based quality assurance metrics for an IMRT system. Methods: Four planners constructed treatment plans for the five IMRT test cases described in TG119. All plans were delivered to a 30 cm X 30 cm X 15 cm solid water phantom in one treatment session in order to minimize session-dependent variation from phantom setup, film quality, machine performance, etc. Composite measurements utilized film and an ionization chamber. Per-field measurements were collected using a diode array device at an effective depth of 5 cm. All data collected were analyzed using the TG119 specifications to determine the confidence limit values for each planner separately and then compared. Results: The mean variance of ion chamber measurements for each planner was within 1.7% of the planned dose. The resulting confidence limits were 3.13%, 1.98%, 3.65%, and 4.39%. Confidence limit values determined by composite film analysis were 8.06%, 13.4%, 9.30%, and 16.5%. Confidence limits from per-field measurements were 1.55%, 0.00%, 0.00%, and 2.89%. Conclusions: For a single IMRT system, the accuracy assessment provided by TG119-based quality assurance metrics showed significant variations in the confidence limits between planners across all composite and per-field evaluations. This observed variation is likely due to the different levels of modulation between each planner's set of plans. Performing the TG119 evaluation using plans produced by a single planner may not provide an adequate estimation of IMRT system accuracy. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3555298]
引用
收藏
页码:1641 / 1648
页数:8
相关论文
共 6 条
[1]   Intensity-modulated radiotherapy: Current status and issues of interest [J].
Boyer, AL ;
Butler, EB ;
DiPetrillo, TA ;
Engler, MJ ;
Fraass, B ;
Grant, W ;
Ling, CC ;
Low, DA ;
Mackie, TR ;
Mohan, R ;
Purdy, JA ;
Roach, M ;
Rosenman, JG ;
Verhey, LJ ;
Wong, JW ;
Cumberlin, RL ;
Stone, H ;
Palta, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :880-914
[2]   Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115
[3]   IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 [J].
Ezzell, Gary A. ;
Burmeister, Jay W. ;
Dogan, Nesrin ;
LoSasso, Thomas J. ;
Mechalakos, James G. ;
Mihailidis, Dimitris ;
Molineu, Andrea ;
Palta, Jatinder R. ;
Ramsey, Chester R. ;
Salter, Bill J. ;
Shi, Jie ;
Xia, Ping ;
Yue, Ning J. ;
Xiao, Ying .
MEDICAL PHYSICS, 2009, 36 (11) :5359-5373
[4]   Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine [J].
Galvin, JM ;
Ezzell, G ;
Eisbrauch, A ;
Yu, C ;
Butler, B ;
Xiao, Y ;
Rosen, I ;
Rosenman, J ;
Sharpe, M ;
Xing, L ;
Xia, P ;
Lomax, T ;
Low, DA ;
Palta, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1616-1634
[5]   Challenges in Credentialing Institutions and Participants in Advanced Technology Multi-institutional Clinical Trials [J].
Radiological Physics Center, The University of Texas M. D. Anderson Cancer Center, Houston, TX, United States .
Int. J. Radiat. Oncol. Biol. Phys., 2008, 1 SUPPL. (S71-S75) :S71-S75
[6]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661