In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator

被引:59
作者
d'Errico, F
Nath, R
Tana, L
Curzio, G
Alberts, WG
机构
[1] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[2] Osped S Chiara, Unita Operat Fis Sanitaria, I-56126 Pisa, Italy
[3] Univ Pisa, Dipartimento Costruz Meccaniche & Nucl, I-56126 Pisa, Italy
[4] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
high-energy medical accelerators; photoneutrons; dosimetry; spectrometry; superheated emulsions; nuclear track detectors;
D O I
10.1118/1.598352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A combination of three superheated drop detectors with different neutron energy responses was developed to evaluate dose-equivalent and energy distributions of photoneutrons in a phantom irradiated by radiotherapy high-energy x-ray beams. One of the three detectors measures the total neutron dose equivalent and the other two measure the contributions from fast neutrons above 1 and 5.5 MeV, respectively. In order to test the new method, the neutron field produced by the 10 cm X 10 cm x-ray beam of an 18 MV radiotherapy accelerator was studied. Measurements were performed inside a tissue-equivalent liquid phantom, at depths of 1, 5, 10 and 15 cm and at lateral distances of 0, 10, and 20 cm from the central axis. These data were used to calculate the average integral dose to the radiotherapy patient from direct neutrons as well as from neutrons transmitted through the accelerator head. The characteristics of the dosimeters were confirmed by results in excellent agreement with those of prior studies. Track etch detectors were also used and provided an independent verification of the validity of this new technique. Within the primary beam, we measured a neutron entrance dose equivalent of 4.5 mSv per Gy of photons. It was observed that fast neutrons above 1 MeV deliver most of the total neutron dose along the beam axis. Their relative contribution increases with depth, from about 60% at the entrance to over 90% at a depth of 10 cm. Thus, the average energy increases with depth in the phantom as neutron spectra harden. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1717 / 1724
页数:8
相关论文
共 28 条
  • [1] *AM ASS PHYS MED, 1986, 19 AM I PHYS
  • [2] SUPERHEATED DROP DETECTOR
    APFEL, RE
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 603 - 608
  • [3] TRANSIENT THERMAL AND MECHANICAL RESPONSE OF WATER SUBJECT TO IONIZING-RADIATION
    APFEL, RE
    SUN, YY
    NATH, R
    [J]. RADIATION RESEARCH, 1992, 131 (02) : 124 - 132
  • [4] *BRIT I RAD, 1983, BRIT J RADIOLOGY S, V17
  • [5] KERMA FACTORS FOR NEUTRON ENERGIES BELOW 30-MEV
    CASWELL, RS
    COYNE, JJ
    RANDOLPH, ML
    [J]. RADIATION RESEARCH, 1980, 83 (02) : 217 - 254
  • [6] SUPERHEATED-DROP (BUBBLE) NEUTRON DETECTORS AND THEIR COMPLIANCE WITH ICRP-60
    DERRICO, F
    ALBERTS, WG
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 54 (3-4) : 357 - 360
  • [7] Advances in superheated drop (bubble) detector techniques
    dErrico, F
    Alberts, WG
    Matzke, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 103 - 108
  • [8] Superheated emulsions: Neutronics and thermodynamics
    dErrico, F
    Apfel, RE
    Curzio, G
    Dietz, E
    Egger, E
    Gualdrini, GF
    Guldbakke, S
    Nath, R
    Siebert, BRL
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 109 - 112
  • [9] Neutron ambient dosimetry with superheated drop (bubble) detectors
    dErrico, F
    Alberts, WG
    Dietz, E
    Gualdrini, G
    Kurkdjian, J
    Noccioni, P
    Siebert, BRL
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 397 - 400
  • [10] DERRICO F, 1995, RADIAT PROT DOSIM, V61, P159