The Clinical Performance of a New Chemiluminescent Immunoassay in Measuring Anti-β2 Glycoprotein 1 and Anti-Cardiolipin Antibodies

被引:7
作者
Zhou, Jiansuo [1 ]
Hou, Xiuzhu [1 ]
Zhang, Hua [2 ]
Wang, Tiancheng [1 ]
Cui, Liyan [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Lab Med, Beijing, Peoples R China
[2] Peking Univ, Hosp 3, Res Ctr Clin Epidemiol, Beijing, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2018年 / 24卷
基金
中国国家自然科学基金;
关键词
Antibodies; Anticardiolipin; Antiphospholipid Syndrome; Luminescence; 13TH INTERNATIONAL-CONGRESS; ANTIPHOSPHOLIPID ANTIBODIES; CONSENSUS GUIDELINES; ANTI-BETA(2)-GLYCOPROTEIN-I ANTIBODIES; EUROPEAN-FORUM; I ANTIBODIES; TASK-FORCE; STANDARDIZATION; ASSAY; DIAGNOSIS;
D O I
10.12659/MSM.910369
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Laboratory criterion is needed for the classification of antiphospholipid syndrome (APS), which contain anticar- diolipin antibodies (aCL) and anti-beta 2-glycoprotein 1 antibodies (a beta 2GP1). They are commonly identified by enzyme-linked immunosorbent assay (ELISA), but lack standardized kits, resulting in substantial variations in the antibody positivity between different laboratories. The emergence of chemiluminescence automated BIO-FLASH may improve the situation. Material/Methods: We selected 185 patients with APS, systemic lupus erythematosus (SLE), infertility, connective tissue dis- ease (CTD), and other conditions in Peking University Third Hospital. We tested the aCL and a beta 2GP1 levels by EUROIMMUN ELISA and 105 patients had at least one positive result for aCL and a beta 2GP1, while the others had negative results. We retested them by chemiluminescence assay (CIA) and analyzed the result and compared the coincidence rate. The IgM levels were retested by AESKU ELISA. Data were analyzed using SPSS. Results: Our result suggested that CIA had good performance for IgG isotype of aCL and a beta 2GP1 in the coincidence rate. The positive coincidence rate of aCL IgM between CIA and EUROIMMUN ELISA was only 41.67%, but two ELISA kits showed good coincidence, CIA and AESKU ELISA had an obviously higher positive rate. CIA and AESKU had a higher coincidence than that of AESKU and EUROIMMUN in al32GP1-IgM. Conclusions: The new automated CIA BIO-FLASH is suitable for detecting aCL and a beta 2GP1 antibodies, especially IgG isotype, which may provide an alternative to time-consuming conventional ELISA method.
引用
收藏
页码:6816 / 6822
页数:7
相关论文
共 38 条
  • [1] Are the current attempts at standardization of antiphospholipid antibodies still useful? Emerging technologies signal a shift in direction
    Andreoli, Laura
    Rizzini, Silvia
    Allegri, Flavio
    Meroni, Pierluigi
    Tincani, Angela
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (04) : 356 - 360
  • [2] Anti-β2-glycoprotein I IgG antibodies from 1-year-old healthy children born to mothers with systemic autoimmune diseases preferentially target domain 4/5: might it be the reason for their 'innocent' profile?
    Andreoli, Laura
    Nalli, Cecilia
    Motta, Mario
    Norman, Gary L.
    Shums, Zakera
    Encabo, Susan
    Binder, Walter L.
    Nuzzo, Monica
    Frassi, Micol
    Lojacono, Andrea
    Avcin, Tadej
    Meroni, Pier-Luigi
    Tincani, Angela
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2011, 70 (02) : 380 - 383
  • [3] Clinical performance evaluation of a novel rapid response chemiluminescent immunoassay for the detection of autoantibodies to extractable nuclear antigens
    Bentow, Chelsea
    Swart, Andreas
    Wu, Jason
    Seaman, Andrea
    Manfredi, Mariangela
    Infantino, Maria
    Benucci, Maurizio
    Lakos, Gabriella
    Mahler, Michael
    [J]. CLINICA CHIMICA ACTA, 2013, 424 : 141 - 147
  • [4] 'Non-criteria' aPL tests: report of a task force and preconference workshop at the 13th International Congress on Antiphospholipid Antibodies, Galveston, TX, USA, April 2010
    Bertolaccini, M. L.
    Amengual, O.
    Atsumi, T.
    Binder, W. L.
    de laat, B.
    Forastiero, R.
    Kutteh, W. H.
    Lambert, M.
    Matsubayashi, H.
    Murthy, V.
    Petri, M.
    Rand, J. H.
    Sanmarco, M.
    Tebo, A. E.
    Pierangeli, S. S.
    [J]. LUPUS, 2011, 20 (02) : 191 - 205
  • [5] Clinical performance of anticardiolipin and antib2 glycoprotein I antibodies using a new automated chemiluminescent assay: superior thrombotic prediction of combined results measured by two different methods
    Chung, Yousun
    Kim, Ji-Eun
    Lim, Hae S.
    Kim, Hyun K.
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2014, 25 (01) : 10 - 15
  • [6] The Mosaic of "Seronegative" Antiphospholipid Syndrome
    Conti, Fabrizio
    Capozzi, Antonella
    Truglia, Simona
    Lococo, Emanuela
    Longo, Agostina
    Misasi, Roberta
    Alessandri, Cristiano
    Valesini, Guido
    Sorice, Maurizio
    [J]. JOURNAL OF IMMUNOLOGY RESEARCH, 2014, 2014
  • [7] Pathogenic anti-β2-glycoprotein I antibodies recognize domain I of β2-glycoprotein I only after a conformational change
    de Laat, B
    Derksen, RHWM
    van Lummel, M
    Pennings, MTT
    de Groot, PG
    [J]. BLOOD, 2006, 107 (05) : 1916 - 1924
  • [8] Analytical and clinical performance of a new, automated assay panel for the diagnosis of antiphospholipid syndrome
    de Moerloose, P.
    Reber, G.
    Musial, J.
    Arnout, J.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (07) : 1540 - 1546
  • [9] Antiphospholipid antibody testing and standardization
    Devreese, K. M. J.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (03) : 352 - 363
  • [10] Standardization of antiphospholipid antibody assays. Where do we stand?
    Devreese, K. M. J.
    [J]. LUPUS, 2012, 21 (07) : 718 - 721