Experimental demonstration of a dynamic bowtie for region-based CT fluence optimization

被引:2
|
作者
Robinson, Vance [1 ]
Smith, Walt [2 ]
Rui, Xue [3 ]
Yin, Zhye [3 ]
Wu, Mingye [4 ]
FitzGerald, Paul [1 ]
De Man, Bruno [3 ]
机构
[1] GE Global Res, Radiat Syst Lab, Niskayuna, NY 12309 USA
[2] GE Global Res, Vibrat Lab, Niskayuna, NY USA
[3] GE Global Res, Image Reconstruct Lab, Niskayuna, NY USA
[4] GE Global Res, CT & Xray Lab, Shanghai, Peoples R China
关键词
computed tomography; dose reduction; dynamic bowtie filter;
D O I
10.1117/12.2216737
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Technology development in Computed Tomography (CT) is driven by clinical needs, for example the need for image quality sufficient for the clinical task, and the need to obtain the required image quality using the lowest possible radiation dose to the patient. One approach to manage dose without compromising image quality is to spatially vary the X-ray flux such that regions of high interest receive more radiation while regions of low interest or regions sensitive to radiation receive less dose. If the region of interest (ROI) is centered at the CT system's axis of rotation, a simple stationary bowtie mounted between the X-ray tube and the patient is sufficient to reduce the X-ray flux outside the central region. If the ROI is off center, then a dynamic bowtie that can track the ROI as the gantry rotates is preferred. We experimentally demonstrated the dynamic bowtie using a design that is relatively simple, low cost, requires no auxiliary power supply, and can be retrofitted to an existing clinical CT scanner. We installed our prototype dynamic bowtie on a clinical CT scanner, and we scanned a phantom with a pre-selected off-center ROI. The dynamic bowtie reduced the X-ray intensity outside the targeted ROI tenfold. As a result, the reconstructed image shows significantly lower noise within the dynamic bowtie ROI compared to regions outside it. Our preliminary results suggest that a dynamic bowtie could be an effective solution for further reducing CT radiation dose.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dynamic region-based mobile multicast
    Wang, Shengling
    Cui, Yong
    Das, Sajal K.
    Wu, Jianping
    WIRELESS COMMUNICATIONS & MOBILE COMPUTING, 2012, 12 (10): : 875 - 890
  • [2] Region-based approximation in approximate dynamic programming
    Sardarmehni, Tohid
    Song, Xingyong
    INTERNATIONAL JOURNAL OF CONTROL, 2024, 97 (02) : 306 - 315
  • [3] A framework of region-based dynamic image fusion
    Wang Zhong-hua
    Qin Zheng
    Liu Yu
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2007, 8 (01): : 56 - 62
  • [5] Limits of Region-Based Dynamic Binary Parallelization
    von Koch, Tobias J. K. Edler
    Franke, Bjoern
    ACM SIGPLAN NOTICES, 2013, 48 (07) : 13 - 22
  • [6] A framework of region-based dynamic image fusion
    Zhong-hua Wang
    Zheng Qin
    Yu Liu
    Journal of Zhejiang University-SCIENCE A, 2007, 8 : 56 - 62
  • [7] Region-based seam optimization for image stitching
    He, Chu
    Li, Yongchao
    Zhang, Yifan
    Liao, Mingsheng
    JOURNAL OF ELECTRONIC IMAGING, 2019, 28 (04)
  • [8] A region-based compilation technique for dynamic compilers
    Suganuma, T
    Yasue, T
    Nakatani, T
    ACM TRANSACTIONS ON PROGRAMMING LANGUAGES AND SYSTEMS, 2006, 28 (01): : 134 - 174
  • [9] Dynamic region-based wavelet compression for telemedicine application
    Li, H
    Atkins, S
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 851 - 859
  • [10] Region-based infrared and visible dynamic image fusion
    Yang, Bo
    Xiao, Gang
    Jing, Zhongliang
    NONLINEAR SCIENCE AND COMPLEXITY, 2007, 1 : 498 - +