Abdominal rapid-kVp-switching dual-energy MDCT with reduced IV contrast compared to conventional MDCT with standard weight-based IV contrast: an intra-patient comparison

被引:26
作者
Clark, Zachary E. [1 ]
Bolus, David N. [2 ]
Little, Mark D. [2 ]
Morgan, Desiree E. [2 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Birmingham, AL 35249 USA
[2] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 04期
关键词
Dual energy CT; Abdomen; IV contrast dose; Renal dysfunction; DOSE REDUCTION; CT; ANGIOGRAPHY; NEPHROPATHY; ENHANCEMENT; PROTOCOLS; SETTINGS; ABDOMEN;
D O I
10.1007/s00261-014-0253-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Perform intra-patient comparison of attenuation values on lower keV dual-energy abdominal CT images using reduced IV contrast dose compared to conventional single energy polychromatic beam abdominal MDCT images using standard IV contrast dose. IRB approved retrospective evaluation of consecutive adults who had both standard IV contrast dosage conventional multiphasic MDCT (SECT) and reduced IV contrast dosage rapid kV-switching dual-energy multiphasic MDCT (rsDECT) of the abdomen. Arterial phase dual-energy 52, 70 and 78 keV simulated monoenergetic HU were compared (t test) to arterial phase SECT HU for: aorta, liver, pancreas, psoas, and hepatic/pancreatic tumors. Contrast to noise ratios (CNR), IV contrast dose reduction and dose-length product (DLP) were recorded. Two blinded independent readers evaluated the CT datasets for subjective image quality based on a five point scale. Twenty-nine scan pairs in 24 subjects (13 M, mean age 64, weight 76.7 kg) were evaluated. Mean reduction in IV contrast dose was 37 %. Mean +/- A SD HU on 52 keV rsDECT vs. SECT were: aorta 534 +/- A 138 vs. 271 +/- A 69; liver 88 +/- A 24 vs. 67 +/- A 16; pancreas 140 +/- A 60 vs. 89 +/- A 40; psoas 63 +/- A 15 vs. 50 +/- A 12 (all p < 0.001). Noise was higher for 52 keV compared to SECT (p < 0.001); CNRs were not significantly different. Mean +/- A SD DLP for rsDECT was 1421 +/- A 563 and SECT 1335 +/- A 562 mGy center dot cm (p = 0.640). For tumor vs. nontumoral parenchyma, mean absolute contrast difference was 58.4 HU on 52 keV, and 29.0 HU on SECT. Nearly all images were rated as good or excellent and there were no statistically significant differences in image quality between the DECT and SECT images. Statistically significant gains in vascular and parenchymal enhancement without adverse effect on CNR or lesion contrast were observed in this intra-patient comparison using reduced IV contrast dose rsDECT compared to standard weight-based IV dose conventional SECT.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 19 条
[1]   Current concepts of contrast-induced nephropathy: A brief review [J].
Chang, Chao-Fu ;
Lin, Chih-Ching .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2013, 76 (12) :673-681
[2]   Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging? [J].
Coursey, Courtney A. ;
Nelson, Rendon C. ;
Boll, Daniel T. ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Neville, Amy M. ;
Marin, Daniele ;
Gupta, Rajan T. ;
Schindera, Sebastian T. .
RADIOGRAPHICS, 2010, 30 (04) :1037-1055
[3]   IV contrast administration for CT: A survey of practices for the screening and prevention of contrast nephropathy [J].
Elicker, BM ;
Cypel, YS ;
Weinreb, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :1651-1658
[4]   Endoleak Detection After Endovascular Repair of Thoracic Aortic Aneurysm Using Dual-Source Dual-Energy CT: Suitable Scanning Protocols and Potential Radiation Dose Reduction [J].
Flors, Lucia ;
Leiva-Salinas, Carlos ;
Norton, Patrick T. ;
Patrie, James T. ;
Hagspiel, Klaus D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) :451-460
[5]   Mortality associated with nephropathy after radiographic contrast exposure [J].
From, Aaron M. ;
Bartholmai, Brian J. ;
Williams, Amy W. ;
Cha, Stephen S. ;
Mcdonald, Furman S. .
MAYO CLINIC PROCEEDINGS, 2008, 83 (10) :1095-1100
[6]   Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies [J].
Godoy, Myrna C. B. ;
Heller, Samantha L. ;
Naidich, David P. ;
Assadourian, Bernard ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Vlahos, Ioannis .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :E11-E17
[7]   Determination of the optimal energy level in spectral CT imaging for displaying abdominal vessels in pediatric patients [J].
Hu, Di ;
Yu, Tong ;
Duan, Xiaomin ;
Peng, Yun ;
Zhai, Renyou .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (03) :589-594
[8]   Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols [J].
Hurwitz, Lynne M. ;
Yoshizumi, Terry T. ;
Goodman, Philip C. ;
Frush, Donald P. ;
Nguyen, Giao ;
Toncheva, Greta ;
Lowry, Carolyn .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) :544-549
[9]  
Kazberg RW, 2006, KIDNEY INT, V100, pS3
[10]   Use of non-linear image blending with dual-energy CT improves vascular visualization in abdominal angiography [J].
Lv, P. ;
Liu, J. ;
Wu, R. ;
Hou, P. ;
Hu, L. ;
Gao, J. .
CLINICAL RADIOLOGY, 2014, 69 (02) :E93-E99