Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer

被引:105
作者
Chen, Yen-An [1 ]
Hirnschall, Nino [1 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Dept Ophthalmol, Vienna Inst Res Ocular Surg, Karl Landsteiner Inst, A-1140 Vienna, Austria
关键词
PARTIAL COHERENCE INTERFEROMETRY; STATISTICAL-METHODS; CATARACT; LASER; SEVERITY;
D O I
10.1016/j.jcrs.2010.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare 2 new optical biometry devices with the present gold standard biometer. SETTING: Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. DESIGN: Evaluation of diagnostic test or technology. METHODS: In patients scheduled for cataract surgery, measurements performed with the current gold standard optical biometer (IOLMaster) were compared with those of 2 new optical biometers, the Lenstar LS 900 (optical low-coherence reflectometry [OLCR] device; substudy 1) and the IOLMaster 500 (partial coherence interferometry [PCI] device; substudy 2). The duration of patient data entry and of 1:he actual measurement process and the time from intraocular lens power calculation to printout were calculated. RESULTS: The mean difference in axial length measurements was 0.01 mm +/- 0.05 (SD) between the gold standard device and the new OLCR device and 0.01 +/- 0.02 mm between the gold standard device and the new PCI device (P = .12 and P < .001, respectively). Measurements with the new OLCR device took significantly longer than with the gold standard device (mean difference 209 +/- 127 seconds), and measurements with the gold standard device took significantly longer than with the new PCI device (mean difference 82 +/- 46 seconds) (both P < .001). CONCLUSIONS: All 3 devices were easy to use for biometry before cataract surgery. Measurements with the new PCI device took half as long as those with the gold standard device. Measurements with the new OLCR device took twice as long as those with the gold standard device.
引用
收藏
页码:513 / 517
页数:5
相关论文
共 16 条
  • [11] Comparison of 2 laser instruments for measuring axial length
    Hoffer, Kenneth J.
    Shammas, H. John
    Savini, Giacomo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) : 644 - 648
  • [12] KATZ J, 1994, INVEST OPHTH VIS SCI, V35, P2461
  • [13] Biometry of cataractous eyes using partial coherence interferometry - Clinical feasibility study of a commercial prototype I
    Kiss, B
    Findl, O
    Menapace, R
    Wirtitsch, M
    Drexler, W
    Hitzenberger, CK
    Fercher, AF
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 224 - 229
  • [14] Influence of severity of nuclear cataract on optical biometry
    Prinz, Ana
    Neumayer, Thomas
    Buehl, Wolf
    Sacu, Stefan
    Drexler, Wolfgang
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07) : 1161 - 1165
  • [15] Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low-Coherence Reflectometer
    Rohrer, Kaspar
    Frueh, Beatrice E.
    Waelti, Rudolf
    Clemetson, Isabelle A.
    Tappeiner, Christoph
    Goldblum, David
    [J]. OPHTHALMOLOGY, 2009, 116 (11) : 2087 - 2092
  • [16] A new non-contact optical device for ocular biometry
    Santodomingo-Rubido, J
    Mallen, EAH
    Gilmartin, B