Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer

被引:105
作者
Chen, Yen-An [1 ]
Hirnschall, Nino [1 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Dept Ophthalmol, Vienna Inst Res Ocular Surg, Karl Landsteiner Inst, A-1140 Vienna, Austria
关键词
PARTIAL COHERENCE INTERFEROMETRY; STATISTICAL-METHODS; CATARACT; LASER; SEVERITY;
D O I
10.1016/j.jcrs.2010.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare 2 new optical biometry devices with the present gold standard biometer. SETTING: Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. DESIGN: Evaluation of diagnostic test or technology. METHODS: In patients scheduled for cataract surgery, measurements performed with the current gold standard optical biometer (IOLMaster) were compared with those of 2 new optical biometers, the Lenstar LS 900 (optical low-coherence reflectometry [OLCR] device; substudy 1) and the IOLMaster 500 (partial coherence interferometry [PCI] device; substudy 2). The duration of patient data entry and of 1:he actual measurement process and the time from intraocular lens power calculation to printout were calculated. RESULTS: The mean difference in axial length measurements was 0.01 mm +/- 0.05 (SD) between the gold standard device and the new OLCR device and 0.01 +/- 0.02 mm between the gold standard device and the new PCI device (P = .12 and P < .001, respectively). Measurements with the new OLCR device took significantly longer than with the gold standard device (mean difference 209 +/- 127 seconds), and measurements with the gold standard device took significantly longer than with the new PCI device (mean difference 82 +/- 46 seconds) (both P < .001). CONCLUSIONS: All 3 devices were easy to use for biometry before cataract surgery. Measurements with the new PCI device took half as long as those with the gold standard device. Measurements with the new OLCR device took twice as long as those with the gold standard device.
引用
收藏
页码:513 / 517
页数:5
相关论文
共 16 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] A new optical low coherence reflectometry device for ocular biometry in cataract patients
    Buckhurst, P. J.
    Wolffsohn, J. S.
    Shah, S.
    Naroo, S. A.
    Davies, L. N.
    Berrow, E. J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) : 949 - 953
  • [3] Accuracy and reproducibility of biometry using partial coherence interferometry
    Connors, R
    Boseman, P
    Olson, RJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 235 - 238
  • [4] Evaluation of the Lenstar LS 900 non-contact biometer
    Cruysberg, L. P. J.
    Doors, M.
    Verbakel, F.
    Berendschot, T. T. J. M.
    De Brabander, J.
    Nuijts, R. M. M. A.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) : 106 - 110
  • [5] Signal quality of biometry in silicone oil-filled eyes using partial coherence laser interferometry
    Dietlein, TS
    Roessler, G
    Lüke, C
    Dinslage, S
    Roters, S
    Jacobi, PC
    Walter, P
    Krieglstein, GK
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) : 1006 - 1010
  • [6] Partial coherence interferometry: A novel approach to biometry in cataract surgery
    Drexler, W
    Findl, O
    Menapace, R
    Rainer, G
    Vass, C
    Hitzenberger, CK
    Fercher, AF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) : 524 - 534
  • [7] Findl O, 2002, DEV OPHTHALMOL, V34, P131
  • [8] The impact of cataract severity on measurement acquisition with the IOLMaster
    Freeman, G
    Pesudovs, K
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (04): : 439 - 442
  • [9] Laser vs ultrasound biometry -: a study of intra- and interobserver variability
    Goel, S
    Chua, C
    Butcher, M
    Jones, CA
    Bagga, P
    Kotta, S
    [J]. EYE, 2004, 18 (05) : 514 - 518
  • [10] Evaluation of a new IOLMaster algorithm to measure axial length
    Hill, Warren
    Angeles, Raymund
    Otani, Todd
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) : 920 - 924