Evaluation of the Beckman Coulter DxC 700 AU chemistry analyzer

被引:9
作者
Bush, V. J. [1 ]
Smola, C. [1 ]
Schmitt, P. [1 ]
机构
[1] Bassett Med Ctr, Cooperstown, NY 13326 USA
关键词
Performance evaluation; Precision; Correlation; Chemistry analyzer; ALBUMIN; DIALYSIS;
D O I
10.1016/j.plabm.2019.e00148
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: We evaluated and defined the analytical performance of the Beckman Coulter DxC 700 AU analyzer compared to the Siemens Dimension Vista 500 analyzer. Design: and Methods: Performance characteristics included intra and inter-run precision, linearity/ analytical measurement range, method correlation, and reference range verification. A total of 53 assays including 11 critical care, 19 general chemistries, 11 proteins, 10 urines, and 2 CSF analyzes were tested. We also evaluated similarities and differences in assay methodologies between the 2 systems. Results: The DxC 700 AU demonstrated excellent precision, comparable analytical measurement ranges and strong method correlation with the Dimension Vista 500 for most serum/plasma assays. 95% of the intra-run and 95% of the inter-run precision QC levels showed <3.0%CV and <6.0%CV, respectively. None of the deviations were clinically significant. The AMRs for all analyzes except 5 met the manufacturer's stated range. ALP, Lactate, U-glucose and CSF-glucose all recovered above the stated upper limit range, while prealbumin showed a smaller range. All analyzes, except 14, showed slopes between 0.9 and 1.1 and/or biases <10%. Only ammonia, ferritin and lipase required significant reference range changes. The urine and CSF assays correlated very well with no adjustments in reference ranges required. Conclusions: The analytical performance of the DxC 700 AU analyzer was acceptable with only a small number of analyzes requiring significant reference range changes.
引用
收藏
页数:9
相关论文
共 15 条
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], 2003, EP06A CLSI
[5]   SERUM-ALBUMIN CONCENTRATION-RELATED HEALTH-CARE FINANCING ADMINISTRATION QUALITY ASSURANCE CRITERION IS METHOD-DEPENDENT - REVISION IS NECESSARY [J].
BLAGG, CR ;
LIEDTKE, RJ ;
BATJER, JD ;
RACOOSIN, B ;
SAWYER, TK ;
WICK, MJ ;
LAWSON, L ;
WILKENS, K .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (02) :138-144
[6]  
Clinical and Laboratory Standards Institute (CLSI), 2014, Evaluation of Precision of Quantitative Measurement Procedures
[7]  
Approved Guideline-Third Edition (EP05-A3), VVolume 24
[8]  
CLSI, 2010, Defining, establishing, and verifying reference intervals in the clinical laboratory
[9]  
CLSI, 2013, CLSI DOCUMENT EP09 A
[10]  
Fraser CG, 2001, Biological variation: from principles to practice