A high performance system to study the influence of temperature in on-line solid-phase extraction capillary electrophoresis

被引:11
作者
Tascon, Marcos [1 ]
Benavente, Fernando [3 ]
Sanz-Nebot, Victoria [3 ]
Gagliardi, Leonardo G. [1 ,2 ]
机构
[1] Univ Nacl La Plata, Lab Invest & Desarrollo Metodos Analit, RA-1900 La Plata, Buenos Aires, Argentina
[2] CIDEPINT CIC CONICET, Ctr Invest & Desarrollo Tecnol Pinturas, RA-1900 La Plata, Buenos Aires, Argentina
[3] Univ Barcelona, Dept Quim Analit, Barcelona, Spain
关键词
Capillary electrophoresis; On-line pre-concentration; Opioid peptides; Solid-Phase extraction; Temperature; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; SPE-CE; COLUMN TEMPERATURE; OPIOID-PEPTIDES; HUMAN PLASMA; SEPARATION; BEHAVIOR; SELECTIVITY; WATER;
D O I
10.1016/j.aca.2014.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel high performance system to control the temperature of the microcartridge in on-line solid phase extraction capillary electrophoresis (SPE-CE) is introduced. The mini-device consists in a thermostatic bath that fits inside of the cassette of any commercial CE instrument, while its temperature is controlled from an external circuit of liquid connecting three different water baths. The circuits are controlled from a switchboard connected to an array of electrovalves that allow to rapidly alternate the water circulation through the mini-thermostatic-bath between temperatures from 5 to 90 degrees C. The combination of the minidevice and the forced-air thermostatization system of the commercial CE instrument allows to optimize independently the temperature of the sample loading, the clean-up, the analyte elution and the electrophoretic separation steps. The system is used to study the effect of temperature on the C18-SPE-CE analysis of the opioid peptides, Dynorphin A (Dyn A), Endomorphin1 (END) and Met-enkephalin (MET), in both standard solutions and in spiked plasma samples. Extraction recoveries demonstrated to depend, with a nonmonotonous trend, on the microcartridge temperature during the sample loading and became maximum at 60 degrees C. Results prove the potential of temperature control to further enhance sensitivity in SPE-CE when analytes are thermally stable. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 30 条
  • [1] [Anonymous], 1965, DYNAMICS CHROMATOGRA
  • [2] Sweeping and new on-line sample preconcentration techniques in capillary electrophoresis
    Aranas, Agnes T.
    Guidote, Armando M., Jr.
    Quirino, Joselito P.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 175 - 185
  • [3] Column temperature as an active variable in the isocratic, normal-phase high-performance liquid chromatography separation of lipophilic metabolites of nonylphenol ethoxylates
    Babay, Paola A.
    Gettar, Raquel T.
    Magallanes, Jorge F.
    Becquart, Elena T.
    Thiele, Bjoern
    Batistoni, Daniel A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) : 227 - 236
  • [4] Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry
    Benavente, Fernando
    Cristina Vescina, M.
    Hernandez, Elena
    Sanz-Nebot, Victoria
    Barbosa, Jose
    Guzman, Norberto A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) : 205 - 212
  • [5] Investigation of commercial sorbents for the analysis of opioid peptides in human plasma by on-line SPE-CE
    Benavente, Fernando
    Medina-Casanellas, Silvia
    Barbosa, Jose
    Sanz-Nebot, Victoria
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (09) : 1294 - 1304
  • [6] Identification of Inorganic Improvised Explosive Devices Using Sequential Injection Capillary Electrophoresis and Contactless Conductivity Detection
    Blanco, Gustavo A.
    Nai, Yi H.
    Hilder, Emily F.
    Shellie, Robert A.
    Dicinoski, Greg W.
    Haddad, Paul R.
    Breadmore, Michael C.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (23) : 9068 - 9075
  • [7] Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems I: Intrinsic performance comparison
    Cabooter, D.
    Heinisch, S.
    Rocca, J. L.
    Clicq, D.
    Desmet, G.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) : 121 - 133
  • [8] Reliability of human serum protein profiles generated with C8 magnetic beads assisted MALDI-TOF mass spectrometry
    de Noo, ME
    Tollenaar, RAEM
    Özalp, A
    Kuppen, PJK
    Bladergroen, MR
    Eilers, PHC
    Deelder, AM
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (22) : 7232 - 7241
  • [9] Modeling retention and selectivity as a function of pH and column temperature in liquid chromatography
    Gagliardi, Leonardo G.
    Castells, Cecilia B.
    Rafols, Clara
    Roses, Marti
    Bosch, Elisabeth
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (16) : 5858 - 5867
  • [10] Guzman N. A., 2011, US patent, Patent No. [8007,725 B2, 8007725]