Physicomechanical properties of biodegradable poly(D,L-lactide) and poly(D,L-lactide-co-glycolide) films in the dry and wet states

被引:0
作者
Kranz, H
Ubrich, N
Maincent, P
Bodmeier, R [1 ]
机构
[1] Free Univ Berlin, Coll Pharm, D-12169 Berlin, Germany
[2] Univ H Poincare, Coll Pharm, F-54001 Nancy, France
关键词
biodegradable polymers; drug delivery systems; film properties; poly(D; L-lactide); L-lactide-co-glycolide);
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The objective of this study was to investigate the mechanical properties (% elongation and puncture strength) of poly(D,L-lactide) (PLA) and poly(D,L-lactide-coglycolide) (PLGA) films as a function of exposure time to an aqueous medium and to correlate the mechanical properties to the degradation/erosion of the polymer as a function of the type of polymer [PLA, weight-average molecular weight (M-W) 270,300, or PLGA 50:50, M-W 56,500], the type of plasticizer [(triethyl citrate (TEC) or acetyltributyl citrate (ATBC)], and the exposure time to pH 7.4 phosphate buffer. The glass transition temperature of the films was measured by differential scanning calorimetry (DSC), the molecular weight by size exclusion chromatography (SEC), and the polymer erosion and hydration gravimetrically. The mechanical properties were strongly affected by the type of polymer and plasticizer. PLGA films showed a faster loss of mechanical integrity. TEC, the water-soluble plasticizer, leached from the films, resulting in major differences in the mechanical properties (flexibility) when compared with films plasticized with the more permanent, water-insoluble ATBC. A significant difference in M-W decrease was seen between plasticizer-free and plasticizer-containing PLA films, but not for PLGA films. Plasticized PLA films, which were above their glass transition temperature in the rubbery state, showed a faster decrease in M-W than plasticizer-free PLA ones, which were in the glassy state. The plasticizer addition to the lower M-W PLGA did not enhance the polymer degradation; the plasticizer-free PLGA was already in the rubbery state. Major differences between the two polymers were also seen in the mass loss and the water uptake studies. After 4 weeks, the mass loss was between 2.6 and 7.0% and the water uptake between 10.1 and 21.1% for PLA films, whereas for PLGA films, the mass loss was between 40.3 and 51.3% and the water uptake between 221.9 and 350.6%. 2000 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 89:1558-1566; 2000.
引用
收藏
页码:1558 / 1566
页数:9
相关论文
共 26 条
[1]   EFFECT OF TEMPERATURE ON MECHANISMS OF DRUG-RELEASE AND MATRIX DEGRADATION OF POLY(D,L-LACTIDE) MICROSPHERES [J].
ASO, Y ;
YOSHIOKA, S ;
PO, ALW ;
TERAO, T .
JOURNAL OF CONTROLLED RELEASE, 1994, 31 (01) :33-39
[2]  
BENOIT JP, 1996, ADV PRODUCTION TECHN, P35
[3]   DRY AND WET STRENGTHS OF POLYMERIC FILMS PREPARED FROM AN AQUEOUS COLLOIDAL POLYMER DISPERSION, EUDRAGIT RS30D [J].
BODMEIER, R ;
PAERATAKUL, O .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 96 (1-3) :129-138
[4]   RECENT ADVANCES ON THE USE OF BIODEGRADABLE MICROPARTICLES AND NANOPARTICLES IN CONTROLLED DRUG-DELIVERY [J].
BRANNONPEPPAS, L .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1995, 116 (01) :1-9
[5]   DEGRADATION OF HIGH-MOLECULAR-WEIGHT POLY(L-LACTIDE) IN ALKALINE-MEDIUM [J].
CAM, D ;
HYON, SH ;
IKADA, Y .
BIOMATERIALS, 1995, 16 (11) :833-843
[6]   Adsorption determines in-vitro protein release rate from biodegradable microspheres: Quantitative analysis of surface area during degradation [J].
Crotts, G ;
Sah, H ;
Park, TG .
JOURNAL OF CONTROLLED RELEASE, 1997, 47 (01) :101-111
[7]   PHYSICOMECHANICAL PROPERTIES OF DEGRADABLE POLYMERS USED IN MEDICAL APPLICATIONS - A COMPARATIVE-STUDY [J].
ENGELBERG, I ;
KOHN, J .
BIOMATERIALS, 1991, 12 (03) :292-304
[8]   MODELING MONOMER RELEASE FROM BIOERODIBLE POLYMERS [J].
GOPFERICH, A ;
LANGER, R .
JOURNAL OF CONTROLLED RELEASE, 1995, 33 (01) :55-69
[9]   BIODEGRADABLE POLYMER SYSTEMS FOR THE SUSTAINED-RELEASE OF POLYPEPTIDES [J].
HUTCHINSON, FG ;
FURR, BJA .
JOURNAL OF CONTROLLED RELEASE, 1990, 13 (2-3) :279-294
[10]  
JIMOH AG, 1995, J CONTROL RELEASE, V34, P87