Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers

被引:201
作者
Wee, KW
Kang, GY
Park, J
Kang, JY
Yoon, DS
Park, JH
Kim, TS [1 ]
机构
[1] Korea Inst Sci & Technol, Microsyst Res Ctr, Seoul 136791, South Korea
[2] Korea Univ, Dept Elect & Comp Engn, Seoul, South Korea
关键词
micro-cantilever; piezoresistivity; nano-mechanics; antigen; antibody;
D O I
10.1016/j.bios.2004.09.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an electro-mechanical biosensor for electrical detection of proteins with disease markers using self-sensing piezoresistive microcantilevers. Electrical detection, via surface stress changes, of antigen-antibody (Ag-Ab) specific binding was accomplished through a direct nano-mechanical response of micro-fabricated self-sensing micro-cantilevers. A piezoresistive sensor measures the film resistance variation with respect to surface stress caused by biomolecules specific binding. When specific binding occurred on a functionalized. An surface, surface stress was induced throughout the cantilever, resulting in cantilever bending and resistance change of the piezoresistive layer. The cantilever biosensors were used for the detection of prostate specific antigen (PSA) and C-reactive proteins (CRP), which are a specific marker of prostate cancer and cardiac disease. From the above experiment, it was revealed that the sensor output voltage was proportional to the injected antigen concentration (without antigen, 10 ng/ml, 100 ng/ml, 1 mu g/ml). PSA and CRP antibodies were found to be very specific for their antigens, respectively. This indicated that the self-sensing micro-cantilever approach is beneficial for detecting disease markers, and our piezoresistive micro-cantilever sensor system is applicable to miniaturized biosensor systems. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1932 / 1938
页数:7
相关论文
共 25 条
  • [1] Development of nanomechanical biosensors for detection of the pesticide DDT
    Alvarez, M
    Calle, A
    Tamayo, J
    Lechuga, LM
    Abad, A
    Montoya, A
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) : 649 - 653
  • [2] Biosensor based on force microscope technology
    Baselt, DR
    Lee, GU
    Colton, RJ
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02): : 789 - 793
  • [3] THE ACUTE-PHASE RESPONSE
    BAUMANN, H
    GAULDIE, J
    [J]. IMMUNOLOGY TODAY, 1994, 15 (02): : 74 - 80
  • [4] Surface stress in the self-assembly of alkanethiols on gold
    Berger, R
    Delamarche, E
    Lang, HP
    Gerber, C
    Gimzewski, JK
    Meyer, E
    Guntherodt, HJ
    [J]. SCIENCE, 1997, 276 (5321) : 2021 - 2024
  • [5] Environmental sensors based on micromachined cantilevers with integrated read-out
    Boisen, A
    Thaysen, J
    Jensenius, H
    Hansen, O
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 11 - 16
  • [6] CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY
    BUTT, HJ
    JASCHKE, M
    [J]. NANOTECHNOLOGY, 1995, 6 (01) : 1 - 7
  • [7] Detection of heavy metal ions using protein-functionalized microcantilever sensors
    Cherian, S
    Gupta, RK
    Mullin, BC
    Thundat, T
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (05) : 411 - 416
  • [8] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318
  • [9] A microcantilever-based alcohol vapor sensor-application and response model
    Jensenius, H
    Thaysen, J
    Rasmussen, AA
    Veje, LH
    Hansen, O
    Boisen, A
    [J]. APPLIED PHYSICS LETTERS, 2000, 76 (18) : 2615 - 2617
  • [10] In situ detection of calcium ions with chemically modified microcantilevers
    Ji, HF
    Thundat, T
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (04) : 337 - 343